Hepatic Plexus Nerve Block for Microwave Ablation of Hepatic Tumors
Seven patients underwent microwave ablation of hepatic tumors; during ablation, a hepatic nerve plexus block was used for pain control. The mean visual analog scale (VAS) score for pain (scale, 0-10) was 0.3 ± 0.5 (SD) at baseline and 2.5 ± 1.4, 2.6 ± 1.4, and 2.3 ± 0.9 at 1, 5, and 10 minutes during ablation. Two patients reported a VAS score of 4 or greater during ablation, which improved in both patients to a VAS score of 3 after one rescue sedation dose. The remaining patients required no additional sedation. No major complication occurred. No patient required conversion to general anesthesia.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:218 |
---|---|
Enthalten in: |
AJR. American journal of roentgenology - 218(2022), 4 vom: 03. Apr., Seite 699-700 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hao, Frank [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 18.04.2022 Date Revised 18.04.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.2214/AJR.21.26779 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM332428540 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM332428540 | ||
003 | DE-627 | ||
005 | 20231225215545.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.2214/AJR.21.26779 |2 doi | |
028 | 5 | 2 | |a pubmed24n1108.xml |
035 | |a (DE-627)NLM332428540 | ||
035 | |a (NLM)34704462 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hao, Frank |e verfasserin |4 aut | |
245 | 1 | 0 | |a Hepatic Plexus Nerve Block for Microwave Ablation of Hepatic Tumors |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.04.2022 | ||
500 | |a Date Revised 18.04.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Seven patients underwent microwave ablation of hepatic tumors; during ablation, a hepatic nerve plexus block was used for pain control. The mean visual analog scale (VAS) score for pain (scale, 0-10) was 0.3 ± 0.5 (SD) at baseline and 2.5 ± 1.4, 2.6 ± 1.4, and 2.3 ± 0.9 at 1, 5, and 10 minutes during ablation. Two patients reported a VAS score of 4 or greater during ablation, which improved in both patients to a VAS score of 3 after one rescue sedation dose. The remaining patients required no additional sedation. No major complication occurred. No patient required conversion to general anesthesia | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Eghbalieh, Navid |e verfasserin |4 aut | |
700 | 1 | |a So, Alexandra |e verfasserin |4 aut | |
700 | 1 | |a Lee, Edward Wolfgang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t AJR. American journal of roentgenology |d 1981 |g 218(2022), 4 vom: 03. Apr., Seite 699-700 |w (DE-627)NLM000037109 |x 1546-3141 |7 nnns |
773 | 1 | 8 | |g volume:218 |g year:2022 |g number:4 |g day:03 |g month:04 |g pages:699-700 |
856 | 4 | 0 | |u http://dx.doi.org/10.2214/AJR.21.26779 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 218 |j 2022 |e 4 |b 03 |c 04 |h 699-700 |