A comparative study on hypofractionated whole-breast irradiation with sequential or simultaneous integrated boost on different positions after breast-conserving surgery
© 2021. The Author(s)..
This study explored the dosimetric difference between hypofractionated whole-breast irradiation (HFWBI) with sequential boost (SEB) and simultaneous integrated boost (SIB) based on supine and prone positions to identify the superior boost mode and superior position. Thirty breast cancer patients eligible for HFWBI after breast-conserving surgery were enrolled. All patients underwent 3DCT simulation scanning in both supine and prone positions. For the SEB-HFWBI plan, the dose prescribed for the planning target volume (PTV) of whole breast (WB) was 2.67 Gy per fraction with a total of 15 fractions, followed by a sequential boost of 3.2 Gy per fraction to the PTV of tumor bed (TB) in 3 fractions. For the SIB-HFWBI plan, the dose prescribed for the PTV of WB was 2.67 Gy per fraction with a total of 15 fractions, with a simultaneously integrated boost of 3.2 Gy per fraction to the PTV of TB with a total of 15 fractions. Regardless of the position, for the PTV of TB, the conformal index (CI) in the SIB-HFWBI plans was greater than those in the SEB-HFWBI plans (T = - 8.114, - 8.114; both P < 0.05). The CI for the PTV of WB increased significantly in the prone position relative to the supine position in both two plans(Z = - 3.340, - 3.501; all P < 0.05). The study suggested that prone SIB-HFWBI might be more suitable for postoperative radiotherapy after breast-conserving surgery for early-stage breast cancer patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:11 |
---|---|
Enthalten in: |
Scientific reports - 11(2021), 1 vom: 09. Sept., Seite 18017 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Yu, Ting [VerfasserIn] |
---|
Links: |
---|
Themen: |
Comparative Study |
---|
Anmerkungen: |
Date Completed 07.12.2021 Date Revised 14.12.2021 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1038/s41598-021-97520-z |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM330464973 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM330464973 | ||
003 | DE-627 | ||
005 | 20231226203540.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1038/s41598-021-97520-z |2 doi | |
028 | 5 | 2 | |a pubmed24n1101.xml |
035 | |a (DE-627)NLM330464973 | ||
035 | |a (NLM)34504253 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Yu, Ting |e verfasserin |4 aut | |
245 | 1 | 2 | |a A comparative study on hypofractionated whole-breast irradiation with sequential or simultaneous integrated boost on different positions after breast-conserving surgery |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 07.12.2021 | ||
500 | |a Date Revised 14.12.2021 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021. The Author(s). | ||
520 | |a This study explored the dosimetric difference between hypofractionated whole-breast irradiation (HFWBI) with sequential boost (SEB) and simultaneous integrated boost (SIB) based on supine and prone positions to identify the superior boost mode and superior position. Thirty breast cancer patients eligible for HFWBI after breast-conserving surgery were enrolled. All patients underwent 3DCT simulation scanning in both supine and prone positions. For the SEB-HFWBI plan, the dose prescribed for the planning target volume (PTV) of whole breast (WB) was 2.67 Gy per fraction with a total of 15 fractions, followed by a sequential boost of 3.2 Gy per fraction to the PTV of tumor bed (TB) in 3 fractions. For the SIB-HFWBI plan, the dose prescribed for the PTV of WB was 2.67 Gy per fraction with a total of 15 fractions, with a simultaneously integrated boost of 3.2 Gy per fraction to the PTV of TB with a total of 15 fractions. Regardless of the position, for the PTV of TB, the conformal index (CI) in the SIB-HFWBI plans was greater than those in the SEB-HFWBI plans (T = - 8.114, - 8.114; both P < 0.05). The CI for the PTV of WB increased significantly in the prone position relative to the supine position in both two plans(Z = - 3.340, - 3.501; all P < 0.05). The study suggested that prone SIB-HFWBI might be more suitable for postoperative radiotherapy after breast-conserving surgery for early-stage breast cancer patients | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Li, Yankang |e verfasserin |4 aut | |
700 | 1 | |a Sun, Tao |e verfasserin |4 aut | |
700 | 1 | |a Xu, Min |e verfasserin |4 aut | |
700 | 1 | |a Wang, Wei |e verfasserin |4 aut | |
700 | 1 | |a Shao, Qian |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Yingjie |e verfasserin |4 aut | |
700 | 1 | |a Li, Jianbin |e verfasserin |4 aut | |
700 | 1 | |a Yu, Jinming |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Scientific reports |d 2011 |g 11(2021), 1 vom: 09. Sept., Seite 18017 |w (DE-627)NLM215703936 |x 2045-2322 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2021 |g number:1 |g day:09 |g month:09 |g pages:18017 |
856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41598-021-97520-z |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 11 |j 2021 |e 1 |b 09 |c 09 |h 18017 |