New Parameter of the Second Half of the P-Wave, P-Wave Duration, and Atrial Conduction Times Predict Atrial Fibrillation during Electrophysiological Studies
© 2021 The Author(s). Published by S. Karger AG, Basel..
OBJECTIVE: Several P-wave parameters reflect atrial conduction characteristics and have been used to predict atrial fibrillation (AF). The aim of this study was to determine the relationship between maximum P-wave duration (PMax) and new P-wave parameters, with atrial conduction times (CT), and to assess their predictive value of AF during electrophysiological studies (AF-EPS).
SUBJECTS AND METHODS: This was a cross-sectional study in 153 randomly selected patients aged 18-70 years, undergoing EPS. The patients were divided into 2 groups designated as no AF-EPS and AF-EPS, depending on whether AF occurred during EPS or not. Different P-wave parameters and atrial CT were compared for both study groups. Subsequently, the predictive value of the P-wave parameters and the atrial CT for AF-EPS was evaluated.
RESULTS: The values of CT, PMax, and maximum Ppeak-Pend interval (Pp-eMax) were significantly higher in patients with AF-EPS. Almost all P-wave parameters were correlated with the left CT. PMax, Pp-eMax, and CT were univariate and multivariate predictors of AF-EPS. The largest ROC area was presented by interatrial CT (0.852; p < 0.001; cutoff value: ≥82.5 ms; sensitivity: 91.1%; specificity: 81.1%). Pp-eMax showed greater sensitivity (79.5%) to discriminate AF-EPS than PMax (72.7%), but the latter had better specificity (60.4% vs. 41.5%).
CONCLUSIONS: Left atrial CT were directly and significantly correlated with PMax and almost all the parameters of the second half of the P-wave. CT, PMax, and Pp-eMax (new parameter) were good predictors of AF-EPS, although CT did more robustly.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:30 |
---|---|
Enthalten in: |
Medical principles and practice : international journal of the Kuwait University, Health Science Centre - 30(2021), 5 vom: 20., Seite 462-469 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Carmona Puerta, Raimundo [VerfasserIn] |
---|
Links: |
---|
Themen: |
Atrial conduction time |
---|
Anmerkungen: |
Date Completed 29.03.2022 Date Revised 29.03.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1159/000518262 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM328927058 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM328927058 | ||
003 | DE-627 | ||
005 | 20231225204008.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1159/000518262 |2 doi | |
028 | 5 | 2 | |a pubmed24n1096.xml |
035 | |a (DE-627)NLM328927058 | ||
035 | |a (NLM)34348309 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Carmona Puerta, Raimundo |e verfasserin |4 aut | |
245 | 1 | 0 | |a New Parameter of the Second Half of the P-Wave, P-Wave Duration, and Atrial Conduction Times Predict Atrial Fibrillation during Electrophysiological Studies |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.03.2022 | ||
500 | |a Date Revised 29.03.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021 The Author(s). Published by S. Karger AG, Basel. | ||
520 | |a OBJECTIVE: Several P-wave parameters reflect atrial conduction characteristics and have been used to predict atrial fibrillation (AF). The aim of this study was to determine the relationship between maximum P-wave duration (PMax) and new P-wave parameters, with atrial conduction times (CT), and to assess their predictive value of AF during electrophysiological studies (AF-EPS) | ||
520 | |a SUBJECTS AND METHODS: This was a cross-sectional study in 153 randomly selected patients aged 18-70 years, undergoing EPS. The patients were divided into 2 groups designated as no AF-EPS and AF-EPS, depending on whether AF occurred during EPS or not. Different P-wave parameters and atrial CT were compared for both study groups. Subsequently, the predictive value of the P-wave parameters and the atrial CT for AF-EPS was evaluated | ||
520 | |a RESULTS: The values of CT, PMax, and maximum Ppeak-Pend interval (Pp-eMax) were significantly higher in patients with AF-EPS. Almost all P-wave parameters were correlated with the left CT. PMax, Pp-eMax, and CT were univariate and multivariate predictors of AF-EPS. The largest ROC area was presented by interatrial CT (0.852; p < 0.001; cutoff value: ≥82.5 ms; sensitivity: 91.1%; specificity: 81.1%). Pp-eMax showed greater sensitivity (79.5%) to discriminate AF-EPS than PMax (72.7%), but the latter had better specificity (60.4% vs. 41.5%) | ||
520 | |a CONCLUSIONS: Left atrial CT were directly and significantly correlated with PMax and almost all the parameters of the second half of the P-wave. CT, PMax, and Pp-eMax (new parameter) were good predictors of AF-EPS, although CT did more robustly | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Atrial conduction time | |
650 | 4 | |a Atrial fibrillation | |
650 | 4 | |a Electrocardiogram | |
650 | 4 | |a Electrophysiological study | |
650 | 4 | |a P-wave | |
700 | 1 | |a Lorenzo Martínez, Elizabeth |e verfasserin |4 aut | |
700 | 1 | |a Rabassa López-Calleja, Magda Alina |e verfasserin |4 aut | |
700 | 1 | |a Padrón Peña, Gustavo |e verfasserin |4 aut | |
700 | 1 | |a Castro Torres, Yaniel |e verfasserin |4 aut | |
700 | 1 | |a Cruz Elizundia, Juan Miguel |e verfasserin |4 aut | |
700 | 1 | |a Rodríguez González, Fernando |e verfasserin |4 aut | |
700 | 1 | |a García Vázquez, Luis Ángel |e verfasserin |4 aut | |
700 | 1 | |a Chávez González, Elibet |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Medical principles and practice : international journal of the Kuwait University, Health Science Centre |d 1996 |g 30(2021), 5 vom: 20., Seite 462-469 |w (DE-627)NLM088686302 |x 1423-0151 |7 nnns |
773 | 1 | 8 | |g volume:30 |g year:2021 |g number:5 |g day:20 |g pages:462-469 |
856 | 4 | 0 | |u http://dx.doi.org/10.1159/000518262 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 30 |j 2021 |e 5 |b 20 |h 462-469 |