Clinical usefulness of the fast protocol of breast diffusion-weighted imaging using 3T magnetic resonance imaging with a 16-channel breast coil
Copyright © 2021 Elsevier Inc. All rights reserved..
We aimed to evaluate the usefulness of a fast protocol of diffusion-weighted imaging (DWI) with one excitation using 3T magnetic resonance imaging (MRI) and a 16-channel breast coil. We analyzed 30 lesions from 27 women between February 2020 and June 2020. The visibility score (from 1 = extremely poor to 5 = excellent) and apparent diffusion coefficient (ADC) value between one and four excitations were evaluated by two readers. The image acquisition time was 40 s for one excitation and 1 min 52 s for four excitations. The visibility scores were 4.630 ± 0.718 and 4.267 ± 1.015 for one excitation and 4.730 ± 0.691 and 4.200 ± 1.000 for four excitations by the two readers. There was no significant difference in the visibility (P = 0.184 and P = 0.423), mean ADC value (P = 0.918 and P = 0.417), and minimum ADC value (P = 0.936 and P = 0.443) between one and four excitations by the two readers. Despite the short acquisition time, the visibility score and ADC values of one-excitation DWI were comparable to that with four excitations. Our fast DWI protocol could provide reproducible visibility and ADC value, potentially helping radiologists to efficiently diagnose patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:78 |
---|---|
Enthalten in: |
Clinical imaging - 78(2021) vom: 01. Okt., Seite 217-222 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Mori, Mio [VerfasserIn] |
---|
Links: |
---|
Themen: |
16-channel breast coil |
---|
Anmerkungen: |
Date Completed 17.08.2021 Date Revised 17.08.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.clinimag.2021.04.022 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM326000607 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM326000607 | ||
003 | DE-627 | ||
005 | 20231225193637.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.clinimag.2021.04.022 |2 doi | |
028 | 5 | 2 | |a pubmed24n1086.xml |
035 | |a (DE-627)NLM326000607 | ||
035 | |a (NLM)34051405 | ||
035 | |a (PII)S0899-7071(21)00189-3 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Mori, Mio |e verfasserin |4 aut | |
245 | 1 | 0 | |a Clinical usefulness of the fast protocol of breast diffusion-weighted imaging using 3T magnetic resonance imaging with a 16-channel breast coil |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 17.08.2021 | ||
500 | |a Date Revised 17.08.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2021 Elsevier Inc. All rights reserved. | ||
520 | |a We aimed to evaluate the usefulness of a fast protocol of diffusion-weighted imaging (DWI) with one excitation using 3T magnetic resonance imaging (MRI) and a 16-channel breast coil. We analyzed 30 lesions from 27 women between February 2020 and June 2020. The visibility score (from 1 = extremely poor to 5 = excellent) and apparent diffusion coefficient (ADC) value between one and four excitations were evaluated by two readers. The image acquisition time was 40 s for one excitation and 1 min 52 s for four excitations. The visibility scores were 4.630 ± 0.718 and 4.267 ± 1.015 for one excitation and 4.730 ± 0.691 and 4.200 ± 1.000 for four excitations by the two readers. There was no significant difference in the visibility (P = 0.184 and P = 0.423), mean ADC value (P = 0.918 and P = 0.417), and minimum ADC value (P = 0.936 and P = 0.443) between one and four excitations by the two readers. Despite the short acquisition time, the visibility score and ADC values of one-excitation DWI were comparable to that with four excitations. Our fast DWI protocol could provide reproducible visibility and ADC value, potentially helping radiologists to efficiently diagnose patients | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a 16-channel breast coil | |
650 | 4 | |a 3T MRI | |
650 | 4 | |a Breast cancer | |
650 | 4 | |a Diffusion-weighted image | |
650 | 4 | |a Fast protocol | |
650 | 4 | |a Magnetic resonance imaging | |
700 | 1 | |a Fujioka, Tomoyuki |e verfasserin |4 aut | |
700 | 1 | |a Katsuta, Leona |e verfasserin |4 aut | |
700 | 1 | |a Yashima, Yuka |e verfasserin |4 aut | |
700 | 1 | |a Nomura, Kyoko |e verfasserin |4 aut | |
700 | 1 | |a Yamaga, Emi |e verfasserin |4 aut | |
700 | 1 | |a Hosoya, Tokuko |e verfasserin |4 aut | |
700 | 1 | |a Oda, Goshi |e verfasserin |4 aut | |
700 | 1 | |a Nakagawa, Tsuyoshi |e verfasserin |4 aut | |
700 | 1 | |a Kubota, Kazunori |e verfasserin |4 aut | |
700 | 1 | |a Tateishi, Ukihide |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical imaging |d 1996 |g 78(2021) vom: 01. Okt., Seite 217-222 |w (DE-627)NLM012624381 |x 1873-4499 |7 nnns |
773 | 1 | 8 | |g volume:78 |g year:2021 |g day:01 |g month:10 |g pages:217-222 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.clinimag.2021.04.022 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 78 |j 2021 |b 01 |c 10 |h 217-222 |