Accuro ultrasound-based system with computer-aided image interpretation compared to traditional palpation technique for neuraxial anesthesia placement in obese parturients undergoing cesarean delivery : a randomized controlled trial
© 2021. Japanese Society of Anesthesiologists..
PURPOSE: Recently, a new handheld ultrasound-based device, called Accuro, has been commercialized with a real-time automated interpretation of lumbar ultrasound images. We hypothesized that the handheld ultrasound device would improve the efficacy and safety of combined spinal-epidural anesthesia (CSEA) for cesarean delivery in obese parturients.
METHODS: Eighty parturients with a body mass index > 30 kg∙m-2 scheduled for elective cesarean delivery were randomly allocated equally (palpation group and ultrasound group). The primary outcome was the first insertion success rate. Secondary outcomes were the time taken to identify the needle puncture site, duration of CSEA procedure, the total time, the rate of parturients who require needle redirections, the number of skin punctures, changes in the intended interspace, and the incidence of complications.
RESULTS: Compared to the palpation group, the first insertion success rate was significantly higher (72.5% vs. 40.0%; P = 0.003), and time taken to identify the needle puncture site was less (30 [26-36] vs. 39 [32-49] seconds; P = 0.001) in the ultrasound group. The rate of parturients who required needle redirections (40.0% vs. 72.5%; P = 0.003) and the incidence of paresthesia were both lower (7.5% vs. 45.0%; P < 0.001). The other outcomes had no significant difference between groups. The mean difference between the epidural depth measured by the handheld ultrasound and needle depth was - 0.29 cm [95% limit of agreement, - 0.52 to - 0.05].
CONCLUSIONS: Our study suggests using the Accuro ultrasound device can enhance the efficacy and safety of CSEA in obese parturients when executed by experienced anesthesiologists, and its automated estimation of epidural depth is accurate.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
Journal of anesthesia - 35(2021), 4 vom: 18. Aug., Seite 475-482 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ni, Xiu [VerfasserIn] |
---|
Links: |
---|
Themen: |
Accuro ultrasound |
---|
Anmerkungen: |
Date Completed 06.08.2021 Date Revised 06.08.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00540-021-02922-y |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM325994625 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM325994625 | ||
003 | DE-627 | ||
005 | 20231225193629.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00540-021-02922-y |2 doi | |
028 | 5 | 2 | |a pubmed24n1086.xml |
035 | |a (DE-627)NLM325994625 | ||
035 | |a (NLM)34050798 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ni, Xiu |e verfasserin |4 aut | |
245 | 1 | 0 | |a Accuro ultrasound-based system with computer-aided image interpretation compared to traditional palpation technique for neuraxial anesthesia placement in obese parturients undergoing cesarean delivery |b a randomized controlled trial |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 06.08.2021 | ||
500 | |a Date Revised 06.08.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021. Japanese Society of Anesthesiologists. | ||
520 | |a PURPOSE: Recently, a new handheld ultrasound-based device, called Accuro, has been commercialized with a real-time automated interpretation of lumbar ultrasound images. We hypothesized that the handheld ultrasound device would improve the efficacy and safety of combined spinal-epidural anesthesia (CSEA) for cesarean delivery in obese parturients | ||
520 | |a METHODS: Eighty parturients with a body mass index > 30 kg∙m-2 scheduled for elective cesarean delivery were randomly allocated equally (palpation group and ultrasound group). The primary outcome was the first insertion success rate. Secondary outcomes were the time taken to identify the needle puncture site, duration of CSEA procedure, the total time, the rate of parturients who require needle redirections, the number of skin punctures, changes in the intended interspace, and the incidence of complications | ||
520 | |a RESULTS: Compared to the palpation group, the first insertion success rate was significantly higher (72.5% vs. 40.0%; P = 0.003), and time taken to identify the needle puncture site was less (30 [26-36] vs. 39 [32-49] seconds; P = 0.001) in the ultrasound group. The rate of parturients who required needle redirections (40.0% vs. 72.5%; P = 0.003) and the incidence of paresthesia were both lower (7.5% vs. 45.0%; P < 0.001). The other outcomes had no significant difference between groups. The mean difference between the epidural depth measured by the handheld ultrasound and needle depth was - 0.29 cm [95% limit of agreement, - 0.52 to - 0.05] | ||
520 | |a CONCLUSIONS: Our study suggests using the Accuro ultrasound device can enhance the efficacy and safety of CSEA in obese parturients when executed by experienced anesthesiologists, and its automated estimation of epidural depth is accurate | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Randomized Controlled Trial | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Accuro ultrasound | |
650 | 4 | |a Neuraxial anesthesia | |
650 | 4 | |a Obese | |
700 | 1 | |a Li, Meng-Zhu |e verfasserin |4 aut | |
700 | 1 | |a Zhou, Shuang-Qiong |e verfasserin |4 aut | |
700 | 1 | |a Xu, Zhen-Dong |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Yue-Qi |e verfasserin |4 aut | |
700 | 1 | |a Yu, Yi-Bing |e verfasserin |4 aut | |
700 | 1 | |a Su, Jing |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Li-Min |e verfasserin |4 aut | |
700 | 1 | |a Liu, Zhi-Qiang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of anesthesia |d 1987 |g 35(2021), 4 vom: 18. Aug., Seite 475-482 |w (DE-627)NLM088729141 |x 1438-8359 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2021 |g number:4 |g day:18 |g month:08 |g pages:475-482 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00540-021-02922-y |3 Volltext |