Comparative evaluation of a dual-target real-time RT-PCR assay for COVID-19 diagnosis and assessment of performance in pooled saliva and nasopharyngeal swab samples
OBJECTIVES: Sensitive molecular diagnostic assays are essential for COVID-19 diagnosis. We evaluated the Hecin Scientific SARS-CoV-2 nucleic acid test kit, a dual-target real-time RT-PCR assay targeting the SARS-CoV-2 N and ORF1ab genes.
METHODS: The Hecin test kit's diagnostic performance in detecting SARS-CoV-2 RNA was compared to the LightMix Modular SARS and Wuhan CoV E-gene kit (TIB Molbiol) and an in-house single-tube nested real-time RT-PCR using 296 clinical specimens, 11 proficiency testing samples, and 30 low-positive deep throat saliva and nasopharyngeal swab (NPS) samples pooled into negative samples in ratios of 1:5, 1:10, and 1:30.
RESULTS: The limit-of-detection of the Hecin test kit was around 500 dC/mL for the N and ORF1ab targets. Sensitivity and specificity of the Hecin test kit were 98.1% (95% CI: 93.4-99.8%) and 100% (98.1-100%), respectively, when measured against the reference method. The Hecin test kit showed fair sensitivity (80%) in low-positive NPS samples pooled in ratios of 1:5 and 1:10. Its performance in pooled samples could be dramatically improved by adjusting the assay Ct cutoff.
CONCLUSION: The Hecin test kit enables sensitive and specific detection of SARS-CoV-2 in clinical samples and pooled samples.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:21 |
---|---|
Enthalten in: |
Expert review of molecular diagnostics - 21(2021), 7 vom: 04. Juli, Seite 741-747 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Yip, Cyril C Y [VerfasserIn] |
---|
Links: |
---|
Themen: |
COVID-19 |
---|
Anmerkungen: |
Date Completed 19.07.2021 Date Revised 19.07.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1080/14737159.2021.1933445 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM325642087 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM325642087 | ||
003 | DE-627 | ||
005 | 20231225192853.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1080/14737159.2021.1933445 |2 doi | |
028 | 5 | 2 | |a pubmed24n1085.xml |
035 | |a (DE-627)NLM325642087 | ||
035 | |a (NLM)34014785 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Yip, Cyril C Y |e verfasserin |4 aut | |
245 | 1 | 0 | |a Comparative evaluation of a dual-target real-time RT-PCR assay for COVID-19 diagnosis and assessment of performance in pooled saliva and nasopharyngeal swab samples |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.07.2021 | ||
500 | |a Date Revised 19.07.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVES: Sensitive molecular diagnostic assays are essential for COVID-19 diagnosis. We evaluated the Hecin Scientific SARS-CoV-2 nucleic acid test kit, a dual-target real-time RT-PCR assay targeting the SARS-CoV-2 N and ORF1ab genes | ||
520 | |a METHODS: The Hecin test kit's diagnostic performance in detecting SARS-CoV-2 RNA was compared to the LightMix Modular SARS and Wuhan CoV E-gene kit (TIB Molbiol) and an in-house single-tube nested real-time RT-PCR using 296 clinical specimens, 11 proficiency testing samples, and 30 low-positive deep throat saliva and nasopharyngeal swab (NPS) samples pooled into negative samples in ratios of 1:5, 1:10, and 1:30 | ||
520 | |a RESULTS: The limit-of-detection of the Hecin test kit was around 500 dC/mL for the N and ORF1ab targets. Sensitivity and specificity of the Hecin test kit were 98.1% (95% CI: 93.4-99.8%) and 100% (98.1-100%), respectively, when measured against the reference method. The Hecin test kit showed fair sensitivity (80%) in low-positive NPS samples pooled in ratios of 1:5 and 1:10. Its performance in pooled samples could be dramatically improved by adjusting the assay Ct cutoff | ||
520 | |a CONCLUSION: The Hecin test kit enables sensitive and specific detection of SARS-CoV-2 in clinical samples and pooled samples | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Video-Audio Media | |
650 | 4 | |a COVID-19 | |
650 | 4 | |a SARS-CoV-2 | |
650 | 4 | |a diagnostic test evaluation | |
650 | 4 | |a pooling | |
650 | 4 | |a real-time RT-PCR | |
650 | 7 | |a RNA, Viral |2 NLM | |
700 | 1 | |a Leung, Kit-Hang |e verfasserin |4 aut | |
700 | 1 | |a Ng, Anthony C K |e verfasserin |4 aut | |
700 | 1 | |a Chan, Kwok-Hung |e verfasserin |4 aut | |
700 | 1 | |a To, Kelvin K W |e verfasserin |4 aut | |
700 | 1 | |a Chan, Jasper F W |e verfasserin |4 aut | |
700 | 1 | |a Hung, Ivan F N |e verfasserin |4 aut | |
700 | 1 | |a Cheng, Vincent C C |e verfasserin |4 aut | |
700 | 1 | |a Sridhar, Siddharth |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Expert review of molecular diagnostics |d 2001 |g 21(2021), 7 vom: 04. Juli, Seite 741-747 |w (DE-627)NLM117852775 |x 1744-8352 |7 nnns |
773 | 1 | 8 | |g volume:21 |g year:2021 |g number:7 |g day:04 |g month:07 |g pages:741-747 |
856 | 4 | 0 | |u http://dx.doi.org/10.1080/14737159.2021.1933445 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 21 |j 2021 |e 7 |b 04 |c 07 |h 741-747 |