Comparative evaluation of Panbio and SD Biosensor antigen rapid diagnostic tests for COVID-19 diagnosis
© 2021 Wiley Periodicals LLC..
The aim of our study was to evaluate the diagnostic performance of two antigen rapid diagnostic tests (Ag-RDTs) to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. We evaluated Panbio and SD-Biosensor Ag-RDTs. We employed 186 polymerase chain reaction (PCR) negative samples to evaluate the specificity and 170 PCR positive samples to assess the sensitivity. We evaluated their sensitivity according to Cycle threshold (C t ) values and days post onset of symptoms (d.p.o.). Tests were compared using the McNemar's test. Agreement was evaluated using the kappa score. Specificity was 100% for Panbio and 97.3% for SD-Biosensor. Sensitivity for samples with C t ≤ 20 was 100% for both assays and for samples with C t = 20-25 was 93.0% (Panbio) and 95.3% (SD-Biosensor) (p = 1.000). Sensitivity decreased for samples wit C t = 25-30 (Panbio: 41.3%, SD-Biosensor: 52.2%, p = 0.125) and samples with C t ≥ 30 (Panbio: 5.0%, SD-Biosensor: 17.5%, p = 0.063). Sensitivity within seven d.p.o. was 87.7% for Panbio and 90.4% for SD-Biosensor and notably decreased after seven d.p.o. Agreement with PCR was excellent for high viral load samples (C t ≤ 25): Panbio, 98.9%, kappa = 0.974; SD-Biosensor, 97.4%, kappa = 0.940. Agreement between Ag-RDTs was excellent (94.9%, kappa = 0.882). Panbio and SD-Biosensor Ag-RDTs showed excellent agreement and diagnostic performance results for samples with high viral loads (C t ≤ 25) or samples within seven d.p.o.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:93 |
---|---|
Enthalten in: |
Journal of medical virology - 93(2021), 9 vom: 15. Sept., Seite 5650-5654 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Pérez-García, Felipe [VerfasserIn] |
---|
Links: |
---|
Themen: |
Antigen rapid diagnostic test |
---|
Anmerkungen: |
Date Completed 02.08.2021 Date Revised 05.10.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/jmv.27089 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM325540330 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM325540330 | ||
003 | DE-627 | ||
005 | 20231225192647.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/jmv.27089 |2 doi | |
028 | 5 | 2 | |a pubmed24n1085.xml |
035 | |a (DE-627)NLM325540330 | ||
035 | |a (NLM)34002864 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Pérez-García, Felipe |e verfasserin |4 aut | |
245 | 1 | 0 | |a Comparative evaluation of Panbio and SD Biosensor antigen rapid diagnostic tests for COVID-19 diagnosis |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 02.08.2021 | ||
500 | |a Date Revised 05.10.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021 Wiley Periodicals LLC. | ||
520 | |a The aim of our study was to evaluate the diagnostic performance of two antigen rapid diagnostic tests (Ag-RDTs) to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. We evaluated Panbio and SD-Biosensor Ag-RDTs. We employed 186 polymerase chain reaction (PCR) negative samples to evaluate the specificity and 170 PCR positive samples to assess the sensitivity. We evaluated their sensitivity according to Cycle threshold (C t ) values and days post onset of symptoms (d.p.o.). Tests were compared using the McNemar's test. Agreement was evaluated using the kappa score. Specificity was 100% for Panbio and 97.3% for SD-Biosensor. Sensitivity for samples with C t ≤ 20 was 100% for both assays and for samples with C t = 20-25 was 93.0% (Panbio) and 95.3% (SD-Biosensor) (p = 1.000). Sensitivity decreased for samples wit C t = 25-30 (Panbio: 41.3%, SD-Biosensor: 52.2%, p = 0.125) and samples with C t ≥ 30 (Panbio: 5.0%, SD-Biosensor: 17.5%, p = 0.063). Sensitivity within seven d.p.o. was 87.7% for Panbio and 90.4% for SD-Biosensor and notably decreased after seven d.p.o. Agreement with PCR was excellent for high viral load samples (C t ≤ 25): Panbio, 98.9%, kappa = 0.974; SD-Biosensor, 97.4%, kappa = 0.940. Agreement between Ag-RDTs was excellent (94.9%, kappa = 0.882). Panbio and SD-Biosensor Ag-RDTs showed excellent agreement and diagnostic performance results for samples with high viral loads (C t ≤ 25) or samples within seven d.p.o | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a COVID-19 | |
650 | 4 | |a Panbio COVID-19 Ag | |
650 | 4 | |a SARS-CoV-2 | |
650 | 4 | |a SD biosensor COVID-19 Ag FIA | |
650 | 4 | |a antigen rapid diagnostic test | |
650 | 4 | |a lateral flow immunoassay | |
650 | 7 | |a Antigens, Viral |2 NLM | |
700 | 1 | |a Romanyk, Juan |e verfasserin |4 aut | |
700 | 1 | |a Moya Gutiérrez, Helena |e verfasserin |4 aut | |
700 | 1 | |a Labrador Ballestero, Andrea |e verfasserin |4 aut | |
700 | 1 | |a Pérez Ranz, Inés |e verfasserin |4 aut | |
700 | 1 | |a González Arroyo, Javier |e verfasserin |4 aut | |
700 | 1 | |a González Ventosa, Victoria |e verfasserin |4 aut | |
700 | 1 | |a Pérez-Tanoira, Ramón |e verfasserin |4 aut | |
700 | 1 | |a Domingo Cruz, Concepción |e verfasserin |4 aut | |
700 | 1 | |a Cuadros-González, Juan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of medical virology |d 1990 |g 93(2021), 9 vom: 15. Sept., Seite 5650-5654 |w (DE-627)NLM000285676 |x 1096-9071 |7 nnns |
773 | 1 | 8 | |g volume:93 |g year:2021 |g number:9 |g day:15 |g month:09 |g pages:5650-5654 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/jmv.27089 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 93 |j 2021 |e 9 |b 15 |c 09 |h 5650-5654 |