Palm-sized methane TDLAS sensor based on a mini-multi-pass cell and a quartz tuning fork as a thermal detector
A palm-sized methane (CH4) tunable diode laser absorption spectroscopy (TDLAS) sensor is reported, in which a quartz tuning fork (QTF) is used as a thermal detector, working together with a mini-multi-pass cell (mini-MPC) to compose a gas detection module (GDM) with a compact dimension of 78 mm × 40 mm × 40 mm. A 1.65 µm near-infrared distributed feedback (DFB) laser is installed in the sensor for CH4 detection. A minimum detection limit (MDL) of 52 ppb is achieved at an integration time of 300 ms, corresponding to a normalized noise equivalent absorption coefficient (NNEA) of 2.1×10-8 cm-1W/Hz1/2. A seven-day continuous monitoring of atmospheric CH4 concentration is implemented to verify the sensor's long-term stability.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:29 |
---|---|
Enthalten in: |
Optics express - 29(2021), 8 vom: 12. Apr., Seite 12357-12364 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Wei, Tingting [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 14.05.2021 published: Print Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1364/OE.423217 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM325363773 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM325363773 | ||
003 | DE-627 | ||
005 | 20231225192300.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1364/OE.423217 |2 doi | |
028 | 5 | 2 | |a pubmed24n1084.xml |
035 | |a (DE-627)NLM325363773 | ||
035 | |a (NLM)33984997 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Wei, Tingting |e verfasserin |4 aut | |
245 | 1 | 0 | |a Palm-sized methane TDLAS sensor based on a mini-multi-pass cell and a quartz tuning fork as a thermal detector |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 14.05.2021 | ||
500 | |a published: Print | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a A palm-sized methane (CH4) tunable diode laser absorption spectroscopy (TDLAS) sensor is reported, in which a quartz tuning fork (QTF) is used as a thermal detector, working together with a mini-multi-pass cell (mini-MPC) to compose a gas detection module (GDM) with a compact dimension of 78 mm × 40 mm × 40 mm. A 1.65 µm near-infrared distributed feedback (DFB) laser is installed in the sensor for CH4 detection. A minimum detection limit (MDL) of 52 ppb is achieved at an integration time of 300 ms, corresponding to a normalized noise equivalent absorption coefficient (NNEA) of 2.1×10-8 cm-1W/Hz1/2. A seven-day continuous monitoring of atmospheric CH4 concentration is implemented to verify the sensor's long-term stability | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Wu, Hongpeng |e verfasserin |4 aut | |
700 | 1 | |a Dong, Lei |e verfasserin |4 aut | |
700 | 1 | |a Cui, Ruyue |e verfasserin |4 aut | |
700 | 1 | |a Jia, Suotang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Optics express |d 1997 |g 29(2021), 8 vom: 12. Apr., Seite 12357-12364 |w (DE-627)NLM120955946 |x 1094-4087 |7 nnns |
773 | 1 | 8 | |g volume:29 |g year:2021 |g number:8 |g day:12 |g month:04 |g pages:12357-12364 |
856 | 4 | 0 | |u http://dx.doi.org/10.1364/OE.423217 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 29 |j 2021 |e 8 |b 12 |c 04 |h 12357-12364 |