PURPOSE: To evaluate the weight of intraocular lenses (IOLs) depending on their material, dioptric power, toricity, focality, and haptic design.
METHODS: Twenty-eight different IOL models from nine different medical companies (a total of 38 IOLs) and 1 capsular tension ring (CTR) were evaluated. IOLs were weighed using a precision scale, in hydrated conditions, as an approximation to their intraocular status.
RESULTS: Hydrophilic IOLs were heavier than hydrophobic lenses (p < 0.001). Regarding toricity, no statistical differences were found comparing toric to non-toric models (p=0.1). Likewise, no differences were found between multifocal IOLs and monofocal IOLs (p=0.19). Dioptric power did not affect IOL weight: IOLs of <15DP had similar weights to those of ≥15D and IOLs of ≥24D had similar weights to those of <24 D (p=0.86 and p=0.59, respectively). Plate-design IOLs were significantly heavier than 1-piece C-loop (p < 0.001), 3-piece C-loop (p < 0.001), and 4-haptic lenses (p=0.001).
CONCLUSIONS: Of the characteristics analyzed that might influence IOL weight, lenses with hydrophilic material and plate-haptic design were found to be heavier. Toricity, focality, and dioptric power had no influence on IOL weight.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:2021 |
---|---|
Enthalten in: |
Journal of ophthalmology - 2021(2021) vom: 19., Seite 6686700 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
López-Vázquez, Ángel [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 22.04.2022 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1155/2021/6686700 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM325201005 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM325201005 | ||
003 | DE-627 | ||
005 | 20231225191930.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1155/2021/6686700 |2 doi | |
028 | 5 | 2 | |a pubmed24n1083.xml |
035 | |a (DE-627)NLM325201005 | ||
035 | |a (NLM)33968444 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a López-Vázquez, Ángel |e verfasserin |4 aut | |
245 | 1 | 0 | |a Weight of Different Intraocular Lenses |b Evaluation of Toricity, Focality, Design, and Material |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 22.04.2022 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2021 Ángel López-Vázquez et al. | ||
520 | |a PURPOSE: To evaluate the weight of intraocular lenses (IOLs) depending on their material, dioptric power, toricity, focality, and haptic design | ||
520 | |a METHODS: Twenty-eight different IOL models from nine different medical companies (a total of 38 IOLs) and 1 capsular tension ring (CTR) were evaluated. IOLs were weighed using a precision scale, in hydrated conditions, as an approximation to their intraocular status | ||
520 | |a RESULTS: Hydrophilic IOLs were heavier than hydrophobic lenses (p < 0.001). Regarding toricity, no statistical differences were found comparing toric to non-toric models (p=0.1). Likewise, no differences were found between multifocal IOLs and monofocal IOLs (p=0.19). Dioptric power did not affect IOL weight: IOLs of <15DP had similar weights to those of ≥15D and IOLs of ≥24D had similar weights to those of <24 D (p=0.86 and p=0.59, respectively). Plate-design IOLs were significantly heavier than 1-piece C-loop (p < 0.001), 3-piece C-loop (p < 0.001), and 4-haptic lenses (p=0.001) | ||
520 | |a CONCLUSIONS: Of the characteristics analyzed that might influence IOL weight, lenses with hydrophilic material and plate-haptic design were found to be heavier. Toricity, focality, and dioptric power had no influence on IOL weight | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
700 | 1 | |a Contreras, Inés |e verfasserin |4 aut | |
700 | 1 | |a Martin-Prieto, Sergio |e verfasserin |4 aut | |
700 | 1 | |a López-Castro, Ángel |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of ophthalmology |d 2009 |g 2021(2021) vom: 19., Seite 6686700 |w (DE-627)NLM19656753X |x 2090-004X |7 nnns |
773 | 1 | 8 | |g volume:2021 |g year:2021 |g day:19 |g pages:6686700 |
856 | 4 | 0 | |u http://dx.doi.org/10.1155/2021/6686700 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 2021 |j 2021 |b 19 |h 6686700 |