Fundamental Frequency and Jitter Percent in MDVP and PRAAT
Published by Elsevier Inc..
PURPOSE: This study initially investigated the relationship between Fundamental Frequency and Jitter Percent across and within MDVP and PRAAT. Subsequently, it explored if the measured acoustic signal's Length or the analysis temporal segment selection impacts potential correlation across the tools' measures.
METHODS: We collected forty-two Maximum Phonation Time acoustic signals from 10 participants with Healthy Voices in a standardized setting. We excluded from enrollment any potential participants having a history of voice disorders or showing an abnormality in a pre-study assessment.
RESULTS: There is no correlation between Jitter percent's values and Fundamental Frequency within either Tool in our healthy voice samples. The Length of the acoustic signal and temporal analysis selection impact the correlation between Jitter Percent measurements across the two tools; The correlation between Fundamental Frequency measurements across the devices was not affected. Means of Fundamental Frequency did not differ across the two devices but show a persistent pattern of greater values in MDVP. Jitter Percent measurements were significantly higher in MDVP CONCLUSIONS: There is a potential for clinicians using PRAAT assessments in the clinic to make inferences from research using MDVP as an analysis tool. Further work is needed in patients with Voice disorders to explore that possibility.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:37 |
---|---|
Enthalten in: |
Journal of voice : official journal of the Voice Foundation - 37(2023), 4 vom: 06. Juli, Seite 496-503 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Mohammed, Ahmed A [VerfasserIn] |
---|
Links: |
---|
Themen: |
Acoustic analysis |
---|
Anmerkungen: |
Date Completed 14.07.2023 Date Revised 18.07.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.jvoice.2021.03.008 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM32480007X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM32480007X | ||
003 | DE-627 | ||
005 | 20231225191103.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jvoice.2021.03.008 |2 doi | |
028 | 5 | 2 | |a pubmed24n1082.xml |
035 | |a (DE-627)NLM32480007X | ||
035 | |a (NLM)33926765 | ||
035 | |a (PII)S0892-1997(21)00107-7 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Mohammed, Ahmed A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Fundamental Frequency and Jitter Percent in MDVP and PRAAT |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 14.07.2023 | ||
500 | |a Date Revised 18.07.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Published by Elsevier Inc. | ||
520 | |a PURPOSE: This study initially investigated the relationship between Fundamental Frequency and Jitter Percent across and within MDVP and PRAAT. Subsequently, it explored if the measured acoustic signal's Length or the analysis temporal segment selection impacts potential correlation across the tools' measures | ||
520 | |a METHODS: We collected forty-two Maximum Phonation Time acoustic signals from 10 participants with Healthy Voices in a standardized setting. We excluded from enrollment any potential participants having a history of voice disorders or showing an abnormality in a pre-study assessment | ||
520 | |a RESULTS: There is no correlation between Jitter percent's values and Fundamental Frequency within either Tool in our healthy voice samples. The Length of the acoustic signal and temporal analysis selection impact the correlation between Jitter Percent measurements across the two tools; The correlation between Fundamental Frequency measurements across the devices was not affected. Means of Fundamental Frequency did not differ across the two devices but show a persistent pattern of greater values in MDVP. Jitter Percent measurements were significantly higher in MDVP CONCLUSIONS: There is a potential for clinicians using PRAAT assessments in the clinic to make inferences from research using MDVP as an analysis tool. Further work is needed in patients with Voice disorders to explore that possibility | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a Acoustic analysis | |
650 | 4 | |a Fundamental frequency | |
650 | 4 | |a Jitter | |
650 | 4 | |a MDVP | |
650 | 4 | |a PRAAT | |
700 | 1 | |a Nagy, Ahmed |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of voice : official journal of the Voice Foundation |d 1996 |g 37(2023), 4 vom: 06. Juli, Seite 496-503 |w (DE-627)NLM07596502X |x 1873-4588 |7 nnns |
773 | 1 | 8 | |g volume:37 |g year:2023 |g number:4 |g day:06 |g month:07 |g pages:496-503 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jvoice.2021.03.008 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 37 |j 2023 |e 4 |b 06 |c 07 |h 496-503 |