What's Wrong with This Picture? A Critical Review of Current Centers for Medicare & Medicaid Services Coverage Criteria for Continuous Glucose Monitoring
Numerous studies have demonstrated the clinical value of continuous glucose monitoring (CGM) in type 1 diabetes and type 2 diabetes populations. However, the eligibility criteria for CGM coverage required by the Centers for Medicare & Medicaid Services (CMS) ignore conclusive evidence that supports CGM use in various diabetes populations that are currently deemed ineligible. This article discusses the limitations and inconsistencies of the CMS eligibility criteria relative to current scientific evidence and proposes workable solutions to address this issue and improve the safety and care of all individuals with diabetes.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:23 |
---|---|
Enthalten in: |
Diabetes technology & therapeutics - 23(2021), 9 vom: 11. Sept., Seite 652-660 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Galindo, Rodolfo J [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 28.03.2022 Date Revised 01.04.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1089/dia.2021.0107 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM323996248 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM323996248 | ||
003 | DE-627 | ||
005 | 20231225185354.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1089/dia.2021.0107 |2 doi | |
028 | 5 | 2 | |a pubmed24n1079.xml |
035 | |a (DE-627)NLM323996248 | ||
035 | |a (NLM)33844588 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Galindo, Rodolfo J |e verfasserin |4 aut | |
245 | 1 | 0 | |a What's Wrong with This Picture? A Critical Review of Current Centers for Medicare & Medicaid Services Coverage Criteria for Continuous Glucose Monitoring |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 28.03.2022 | ||
500 | |a Date Revised 01.04.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Numerous studies have demonstrated the clinical value of continuous glucose monitoring (CGM) in type 1 diabetes and type 2 diabetes populations. However, the eligibility criteria for CGM coverage required by the Centers for Medicare & Medicaid Services (CMS) ignore conclusive evidence that supports CGM use in various diabetes populations that are currently deemed ineligible. This article discusses the limitations and inconsistencies of the CMS eligibility criteria relative to current scientific evidence and proposes workable solutions to address this issue and improve the safety and care of all individuals with diabetes | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Review | |
650 | 4 | |a Centers for Medicare & Medicaid Services | |
650 | 4 | |a Continuous glucose monitoring | |
650 | 4 | |a Insurance coverage | |
650 | 4 | |a Type 1 diabetes | |
650 | 4 | |a Type 2 diabetes | |
650 | 7 | |a Blood Glucose |2 NLM | |
700 | 1 | |a Parkin, Christopher G |e verfasserin |4 aut | |
700 | 1 | |a Aleppo, Grazia |e verfasserin |4 aut | |
700 | 1 | |a Carlson, Anders L |e verfasserin |4 aut | |
700 | 1 | |a Kruger, Davida F |e verfasserin |4 aut | |
700 | 1 | |a Levy, Carol J |e verfasserin |4 aut | |
700 | 1 | |a Umpierrez, Guillermo E |e verfasserin |4 aut | |
700 | 1 | |a McGill, Janet B |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diabetes technology & therapeutics |d 1999 |g 23(2021), 9 vom: 11. Sept., Seite 652-660 |w (DE-627)NLM113690495 |x 1557-8593 |7 nnns |
773 | 1 | 8 | |g volume:23 |g year:2021 |g number:9 |g day:11 |g month:09 |g pages:652-660 |
856 | 4 | 0 | |u http://dx.doi.org/10.1089/dia.2021.0107 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 23 |j 2021 |e 9 |b 11 |c 09 |h 652-660 |