Open and Closed Endotracheal Suction Systems Divergently Affect Pulmonary Function in Mechanically Ventilated Subjects
Copyright © 2021 by Daedalus Enterprises..
BACKGROUND: In mechanically ventilated subjects, intra-tracheal secretions can be aspirated with either open suction systems (OSS) or closed suction systems (CSS). In contrast to CSS, conventional OSS require temporarily disconnecting the patient from the ventilator, which briefly diminishes PEEP and oxygen supply. On the other hand, CSS are more expensive and less effective at aspirating secretions. Thus, it was hypothesized that the 2 procedures differentially affect pulmonary and cardiovascular parameters after suction.
METHODS: Subjects in the ICU (N = 66) were quasi-randomized for initial treatment with OSS or CSS in a crossover design. To compare the potential for these suction systems to compromise cardiorespiratory stability, changes in cardiopulmonary physiology were assessed from before to just after use of each suction system (three 10-s aspirations).
RESULTS: For most pulmonary and cardiovascular parameters (ie, peak inspiratory pressure, airway resistance, pressure plateau, heart rate, and arterial pressures), the effects of aspiration inversely correlated with baseline values for that parameter, with a similar regression slope between suction systems. However, when controlling for baseline values, OSS caused significantly greater increases in airway resistance and peak inspiratory pressure (P < .001 and < .01 vs CSS, respectively).
CONCLUSIONS: Elevated airway resistance prior to endotracheal suction may justify use of a CSS and contraindicate a conventional OSS in mechanically ventilated subjects. Adoption of this approach into clinical guidelines may prevent suction-induced pulmonary injury in subjects, especially for those with underlying diseases involving increased airway resistance or increased alveolar pressure. (ClinicalTrials.gov registration: NCT03256214.).
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:66 |
---|---|
Enthalten in: |
Respiratory care - 66(2021), 5 vom: 09. Mai, Seite 785-792 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Raimundo, Rodrigo Daminello [VerfasserIn] |
---|
Links: |
---|
Themen: |
Airway resistance |
---|
Anmerkungen: |
Date Completed 19.05.2021 Date Revised 22.03.2023 published: Print-Electronic ClinicalTrials.gov: NCT03256214 Citation Status MEDLINE |
---|
doi: |
10.4187/respcare.08511 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM322452198 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM322452198 | ||
003 | DE-627 | ||
005 | 20231225182053.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.4187/respcare.08511 |2 doi | |
028 | 5 | 2 | |a pubmed24n1074.xml |
035 | |a (DE-627)NLM322452198 | ||
035 | |a (NLM)33688090 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Raimundo, Rodrigo Daminello |e verfasserin |4 aut | |
245 | 1 | 0 | |a Open and Closed Endotracheal Suction Systems Divergently Affect Pulmonary Function in Mechanically Ventilated Subjects |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.05.2021 | ||
500 | |a Date Revised 22.03.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a ClinicalTrials.gov: NCT03256214 | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2021 by Daedalus Enterprises. | ||
520 | |a BACKGROUND: In mechanically ventilated subjects, intra-tracheal secretions can be aspirated with either open suction systems (OSS) or closed suction systems (CSS). In contrast to CSS, conventional OSS require temporarily disconnecting the patient from the ventilator, which briefly diminishes PEEP and oxygen supply. On the other hand, CSS are more expensive and less effective at aspirating secretions. Thus, it was hypothesized that the 2 procedures differentially affect pulmonary and cardiovascular parameters after suction | ||
520 | |a METHODS: Subjects in the ICU (N = 66) were quasi-randomized for initial treatment with OSS or CSS in a crossover design. To compare the potential for these suction systems to compromise cardiorespiratory stability, changes in cardiopulmonary physiology were assessed from before to just after use of each suction system (three 10-s aspirations) | ||
520 | |a RESULTS: For most pulmonary and cardiovascular parameters (ie, peak inspiratory pressure, airway resistance, pressure plateau, heart rate, and arterial pressures), the effects of aspiration inversely correlated with baseline values for that parameter, with a similar regression slope between suction systems. However, when controlling for baseline values, OSS caused significantly greater increases in airway resistance and peak inspiratory pressure (P < .001 and < .01 vs CSS, respectively) | ||
520 | |a CONCLUSIONS: Elevated airway resistance prior to endotracheal suction may justify use of a CSS and contraindicate a conventional OSS in mechanically ventilated subjects. Adoption of this approach into clinical guidelines may prevent suction-induced pulmonary injury in subjects, especially for those with underlying diseases involving increased airway resistance or increased alveolar pressure. (ClinicalTrials.gov registration: NCT03256214.) | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Randomized Controlled Trial | |
650 | 4 | |a airway resistance | |
650 | 4 | |a endotracheal aspiration | |
650 | 4 | |a lung | |
650 | 4 | |a mechanical ventilation | |
650 | 4 | |a pulmonary compliance | |
650 | 4 | |a pulmonary pressure | |
700 | 1 | |a Sato, Monica Akemi |e verfasserin |4 aut | |
700 | 1 | |a da Silva, Talita Dias |e verfasserin |4 aut | |
700 | 1 | |a de Abreu, Luiz Carlos |e verfasserin |4 aut | |
700 | 1 | |a Valenti, Vitor Engrácia |e verfasserin |4 aut | |
700 | 1 | |a Riggs, Daniel William |e verfasserin |4 aut | |
700 | 1 | |a Perrow Carll, Alex |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Respiratory care |d 1974 |g 66(2021), 5 vom: 09. Mai, Seite 785-792 |w (DE-627)NLM07486520X |x 1943-3654 |7 nnns |
773 | 1 | 8 | |g volume:66 |g year:2021 |g number:5 |g day:09 |g month:05 |g pages:785-792 |
856 | 4 | 0 | |u http://dx.doi.org/10.4187/respcare.08511 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 66 |j 2021 |e 5 |b 09 |c 05 |h 785-792 |