Perioperative predictability of unsatisfactory functional outcomes 6 months after hip arthroplasty
© 2021 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved..
BACKGROUND: Aiming at an early identification of patients with an unsatisfactory outcome after hip arthroplasty we investigated the pre-, intra- and early postoperative predictability.
METHODS: Using logistic regression models at nine different time points we calculated the area under the curve of the receiver operating characteristic (ROC-AUC) to compare the predictability of an unsatisfactory outcome.
RESULTS: The predictability of unsatisfactory outcomes increased significantly from a ROC-AUC (95% CI) of 0.73 (0.62-0.84) in the preoperative setting to 0.85 (0.77-0.94) on day 2 after surgery.
CONCLUSION: Most of the patients with unsatisfactory outcomes can be identified during the first days after surgery.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:24 |
---|---|
Enthalten in: |
Journal of orthopaedics - 24(2021) vom: 10. März, Seite 34-41 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Jakuscheit, Axel [VerfasserIn] |
---|
Links: |
---|
Themen: |
Functional outcome |
---|
Anmerkungen: |
Date Revised 21.04.2022 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.jor.2021.02.014 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM322362601 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM322362601 | ||
003 | DE-627 | ||
005 | 20231225181901.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jor.2021.02.014 |2 doi | |
028 | 5 | 2 | |a pubmed24n1074.xml |
035 | |a (DE-627)NLM322362601 | ||
035 | |a (NLM)33679026 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Jakuscheit, Axel |e verfasserin |4 aut | |
245 | 1 | 0 | |a Perioperative predictability of unsatisfactory functional outcomes 6 months after hip arthroplasty |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 21.04.2022 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2021 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved. | ||
520 | |a BACKGROUND: Aiming at an early identification of patients with an unsatisfactory outcome after hip arthroplasty we investigated the pre-, intra- and early postoperative predictability | ||
520 | |a METHODS: Using logistic regression models at nine different time points we calculated the area under the curve of the receiver operating characteristic (ROC-AUC) to compare the predictability of an unsatisfactory outcome | ||
520 | |a RESULTS: The predictability of unsatisfactory outcomes increased significantly from a ROC-AUC (95% CI) of 0.73 (0.62-0.84) in the preoperative setting to 0.85 (0.77-0.94) on day 2 after surgery | ||
520 | |a CONCLUSION: Most of the patients with unsatisfactory outcomes can be identified during the first days after surgery | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Functional outcome | |
650 | 4 | |a Hip arthroplasty | |
650 | 4 | |a Postoperative pain | |
650 | 4 | |a Prediction model | |
700 | 1 | |a Weth, Johannes |e verfasserin |4 aut | |
700 | 1 | |a Lichtner, Gregor |e verfasserin |4 aut | |
700 | 1 | |a Horas, Konstantin |e verfasserin |4 aut | |
700 | 1 | |a Rehberg-Klug, Benno |e verfasserin |4 aut | |
700 | 1 | |a von Dincklage, Falk |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of orthopaedics |d 2013 |g 24(2021) vom: 10. März, Seite 34-41 |w (DE-627)NLM234216107 |x 0972-978X |7 nnns |
773 | 1 | 8 | |g volume:24 |g year:2021 |g day:10 |g month:03 |g pages:34-41 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jor.2021.02.014 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 24 |j 2021 |b 10 |c 03 |h 34-41 |