Diagnostic accuracy of lung ultrasound for SARS-CoV-2 : a retrospective cohort study
BACKGROUND: As medical infrastructures are strained by SARS-CoV-2, rapid and accurate screening tools are essential. In portions of the world, reverse transcription polymerase chain reaction (RT-PCR) testing remains slow and in limited supply, and computed tomography is expensive, inefficient, and involves exposure to ionizing radiation. Multiple studies evaluating the efficiency of lung point-of-care ultrasound (POCUS) have been published recently, but include relatively small cohorts and often focus on characteristics associated with severe illness rather than screening efficacy. This study utilizes a retrospective cohort to evaluate the test characteristics (sensitivity, specificity, likelihood ratios, predictive values) of lung POCUS in the diagnosis of SARS-CoV-2, and to determine lung score cutoffs that maximize performance for use as a screening tool.
RESULTS: Lung POCUS examinations had sensitivity 86%, specificity 71.6%, NPV 81.7%, and PPV 77.7%. The Lung Ultrasound Score had an area under the curve of 0.84 (95% CI 0.78, 0.90). When including only complete examinations visualizing 12 lung fields, lung POCUS had sensitivity 90.9% and specificity 75.6%, with NPV 87.2% and PPV 82.0% and an area under the curve of 0.89 (95% CI 0.83, 0.96). Lung POCUS was less accurate in patients with a history of interstitial lung disease, severe emphysema, and heart failure.
CONCLUSIONS: When applied in the appropriate patient population, lung POCUS is an inexpensive and reliable tool for rapid screening and diagnosis of SARS-CoV-2 in symptomatic patients with influenza-like illness. Adoption of lung POCUS screening for SARS-CoV-2 may identify patients who do not require additional testing and reduce the need for RT-PCR testing in resource-limited environments and during surge periods.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
The ultrasound journal - 13(2021), 1 vom: 01. März, Seite 12 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Brenner, Daniel S [VerfasserIn] |
---|
Links: |
---|
Themen: |
COVID-19 |
---|
Anmerkungen: |
Date Revised 10.11.2022 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1186/s13089-021-00217-7 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM32202692X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM32202692X | ||
003 | DE-627 | ||
005 | 20231225181146.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s13089-021-00217-7 |2 doi | |
028 | 5 | 2 | |a pubmed24n1073.xml |
035 | |a (DE-627)NLM32202692X | ||
035 | |a (NLM)33644829 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Brenner, Daniel S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Diagnostic accuracy of lung ultrasound for SARS-CoV-2 |b a retrospective cohort study |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 10.11.2022 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a BACKGROUND: As medical infrastructures are strained by SARS-CoV-2, rapid and accurate screening tools are essential. In portions of the world, reverse transcription polymerase chain reaction (RT-PCR) testing remains slow and in limited supply, and computed tomography is expensive, inefficient, and involves exposure to ionizing radiation. Multiple studies evaluating the efficiency of lung point-of-care ultrasound (POCUS) have been published recently, but include relatively small cohorts and often focus on characteristics associated with severe illness rather than screening efficacy. This study utilizes a retrospective cohort to evaluate the test characteristics (sensitivity, specificity, likelihood ratios, predictive values) of lung POCUS in the diagnosis of SARS-CoV-2, and to determine lung score cutoffs that maximize performance for use as a screening tool | ||
520 | |a RESULTS: Lung POCUS examinations had sensitivity 86%, specificity 71.6%, NPV 81.7%, and PPV 77.7%. The Lung Ultrasound Score had an area under the curve of 0.84 (95% CI 0.78, 0.90). When including only complete examinations visualizing 12 lung fields, lung POCUS had sensitivity 90.9% and specificity 75.6%, with NPV 87.2% and PPV 82.0% and an area under the curve of 0.89 (95% CI 0.83, 0.96). Lung POCUS was less accurate in patients with a history of interstitial lung disease, severe emphysema, and heart failure | ||
520 | |a CONCLUSIONS: When applied in the appropriate patient population, lung POCUS is an inexpensive and reliable tool for rapid screening and diagnosis of SARS-CoV-2 in symptomatic patients with influenza-like illness. Adoption of lung POCUS screening for SARS-CoV-2 may identify patients who do not require additional testing and reduce the need for RT-PCR testing in resource-limited environments and during surge periods | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a COVID-19 | |
650 | 4 | |a Diagnosis | |
650 | 4 | |a POCUS | |
650 | 4 | |a RT-PCR | |
650 | 4 | |a SARS-CoV-2 | |
650 | 4 | |a Triage | |
650 | 4 | |a Ultrasound | |
700 | 1 | |a Liu, Gigi Y |e verfasserin |4 aut | |
700 | 1 | |a Omron, Rodney |e verfasserin |4 aut | |
700 | 1 | |a Tang, Olive |e verfasserin |4 aut | |
700 | 1 | |a Garibaldi, Brian T |e verfasserin |4 aut | |
700 | 1 | |a Fong, Tiffany C |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The ultrasound journal |d 2019 |g 13(2021), 1 vom: 01. März, Seite 12 |w (DE-627)NLM299707652 |x 2524-8987 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2021 |g number:1 |g day:01 |g month:03 |g pages:12 |
856 | 4 | 0 | |u http://dx.doi.org/10.1186/s13089-021-00217-7 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2021 |e 1 |b 01 |c 03 |h 12 |