Short communication : Diagnostic accuracy of the Petrifilm culture system for identifying colostrum with excessive bacterial contamination in Quebec dairy herds
Copyright © 2021 American Dairy Science Association. Published by Elsevier Inc. All rights reserved..
The objective of this study was to validate the diagnostic accuracy of the Petrifilm culture system (3M, St. Paul, MN) for identifying colostrum with excessive bacterial contamination. An observational cross-sectional study was conducted between October 2015 and February 2016. Two colostrum aliquots were collected during the first meal of 332 calves (33 commercial Holstein dairy farms) in Quebec, Canada. One aliquot per calf was used to quantify the total bacteria count and the total coliform count using standard bacteriological laboratory testing (reference test). These results were dichotomized to identify colostrum with excessive bacterial contamination [aerobic count plate (AC) >100,000 cfu/mL; coliform count plate (CC) >10,000 cfu/mL]. The Petrifilm system was used to quantify both aerobic and coliform contamination of the other colostrum aliquot from each calf. As such, AC and CC were used according to the manufacturer's recommendations. The area under the curve of the receiver operating characteristic curve of AC and CC compared with the laboratory were 0.83, and 0.95, respectively. Using the optimal threshold of >24,000 cfu/mL for AC results, the Petrifilm system had a sensitivity (Se) of 69%, specificity (Sp) of 86%, and a kappa value of 0.54. Using the optimal threshold of >4,000 cfu/mL for CC results, the Petrifilm system had a Se of 93%, Sp of 90%, and kappa value of 0.64. Overall, these results suggest that the Petrifilm system is an appropriate alternative for identifying colostrum with excessive bacterial contamination.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:104 |
---|---|
Enthalten in: |
Journal of dairy science - 104(2021), 4 vom: 01. Apr., Seite 4923-4928 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Morin, M P [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 14.04.2021 Date Revised 14.04.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.3168/jds.2020-19474 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM31923150X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM31923150X | ||
003 | DE-627 | ||
005 | 20231225171020.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3168/jds.2020-19474 |2 doi | |
028 | 5 | 2 | |a pubmed24n1064.xml |
035 | |a (DE-627)NLM31923150X | ||
035 | |a (NLM)33358819 | ||
035 | |a (PII)S0022-0302(20)31100-0 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Morin, M P |e verfasserin |4 aut | |
245 | 1 | 0 | |a Short communication |b Diagnostic accuracy of the Petrifilm culture system for identifying colostrum with excessive bacterial contamination in Quebec dairy herds |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 14.04.2021 | ||
500 | |a Date Revised 14.04.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2021 American Dairy Science Association. Published by Elsevier Inc. All rights reserved. | ||
520 | |a The objective of this study was to validate the diagnostic accuracy of the Petrifilm culture system (3M, St. Paul, MN) for identifying colostrum with excessive bacterial contamination. An observational cross-sectional study was conducted between October 2015 and February 2016. Two colostrum aliquots were collected during the first meal of 332 calves (33 commercial Holstein dairy farms) in Quebec, Canada. One aliquot per calf was used to quantify the total bacteria count and the total coliform count using standard bacteriological laboratory testing (reference test). These results were dichotomized to identify colostrum with excessive bacterial contamination [aerobic count plate (AC) >100,000 cfu/mL; coliform count plate (CC) >10,000 cfu/mL]. The Petrifilm system was used to quantify both aerobic and coliform contamination of the other colostrum aliquot from each calf. As such, AC and CC were used according to the manufacturer's recommendations. The area under the curve of the receiver operating characteristic curve of AC and CC compared with the laboratory were 0.83, and 0.95, respectively. Using the optimal threshold of >24,000 cfu/mL for AC results, the Petrifilm system had a sensitivity (Se) of 69%, specificity (Sp) of 86%, and a kappa value of 0.54. Using the optimal threshold of >4,000 cfu/mL for CC results, the Petrifilm system had a Se of 93%, Sp of 90%, and kappa value of 0.64. Overall, these results suggest that the Petrifilm system is an appropriate alternative for identifying colostrum with excessive bacterial contamination | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Petrifilm | |
650 | 4 | |a bacteria | |
650 | 4 | |a coliform | |
650 | 4 | |a colostrum | |
700 | 1 | |a Dubuc, J |e verfasserin |4 aut | |
700 | 1 | |a Freycon, P |e verfasserin |4 aut | |
700 | 1 | |a Buczinski, S |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of dairy science |d 1965 |g 104(2021), 4 vom: 01. Apr., Seite 4923-4928 |w (DE-627)NLM000005533 |x 1525-3198 |7 nnns |
773 | 1 | 8 | |g volume:104 |g year:2021 |g number:4 |g day:01 |g month:04 |g pages:4923-4928 |
856 | 4 | 0 | |u http://dx.doi.org/10.3168/jds.2020-19474 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 104 |j 2021 |e 4 |b 01 |c 04 |h 4923-4928 |