The safety and feasibility of the simultaneous use of 180-W GreenLight laser for prostate vaporization during concomitant surgery
OBJECTIVES: To explore the safety and feasibility of photo-selective vaporization of the prostate (PVP) with GreenLight XPS 180 Watt laser (GL-180- W XPS) combined with other surgical procedures.
MATERIAL AND METHODS: Data on patients in whom GL-180-W XPS was performed to relieve lower urinary tract symptoms/ benign prostatic hyperplasia (LUTS/BPH) symptoms were extracted from a multi-institutional database (2011-2016). Patients were stratified into two groups. In the first all patients who had GL-180-W XPS with a concomitant procedure during the same surgical session were included as cases while those who underwent GL-180-W XPS PVP only were included as control.
RESULTS: A total of 487 patients were included. Fifty-eight (11.9%) patients underwent concomitant procedures. Multivariable linear regression models failed to find an association between concomitant procedures and longer laser time (p = 0.4). Similarly, multivariable linear regression models failed to find an association between concomitant procedures and laser time even when the analyses were repeated and stratified into endoscopic (p = 0.6) and open/laparoscopic (p = 0.4) procedures. Multivariable logistic regression models failed to demonstrate any association between concomitant procedures and early complications (OR:1.39, CI: 0.379-2.44, p = 0.2), late complications (OR:1.84, CI:0.78-3.98; p = 0.1) and acute urinary retention (OR:1.84, CI:0.78-3.98; p = 0.1). When the analyses were repeated and the concomitant procedures stratified into endoscopic and open/laparoscopic ones, they yielded virtually the same results.
CONCLUSIONS: GL-180-W XPS PVP could be safely performed in concomitant endoscopic or open/laparoscopic surgery. These results should be taken into consideration in the counseling of the patient who might choose to undergo simultaneous procedures.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:92 |
---|---|
Enthalten in: |
Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica - 92(2020), 4 vom: 17. Dez. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Castellucci, Roberto [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 28.06.2021 Date Revised 28.06.2021 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.4081/aiua.2020.4.297 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM319135942 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM319135942 | ||
003 | DE-627 | ||
005 | 20231225170818.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.4081/aiua.2020.4.297 |2 doi | |
028 | 5 | 2 | |a pubmed24n1063.xml |
035 | |a (DE-627)NLM319135942 | ||
035 | |a (NLM)33348957 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Castellucci, Roberto |e verfasserin |4 aut | |
245 | 1 | 4 | |a The safety and feasibility of the simultaneous use of 180-W GreenLight laser for prostate vaporization during concomitant surgery |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 28.06.2021 | ||
500 | |a Date Revised 28.06.2021 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVES: To explore the safety and feasibility of photo-selective vaporization of the prostate (PVP) with GreenLight XPS 180 Watt laser (GL-180- W XPS) combined with other surgical procedures | ||
520 | |a MATERIAL AND METHODS: Data on patients in whom GL-180-W XPS was performed to relieve lower urinary tract symptoms/ benign prostatic hyperplasia (LUTS/BPH) symptoms were extracted from a multi-institutional database (2011-2016). Patients were stratified into two groups. In the first all patients who had GL-180-W XPS with a concomitant procedure during the same surgical session were included as cases while those who underwent GL-180-W XPS PVP only were included as control | ||
520 | |a RESULTS: A total of 487 patients were included. Fifty-eight (11.9%) patients underwent concomitant procedures. Multivariable linear regression models failed to find an association between concomitant procedures and longer laser time (p = 0.4). Similarly, multivariable linear regression models failed to find an association between concomitant procedures and laser time even when the analyses were repeated and stratified into endoscopic (p = 0.6) and open/laparoscopic (p = 0.4) procedures. Multivariable logistic regression models failed to demonstrate any association between concomitant procedures and early complications (OR:1.39, CI: 0.379-2.44, p = 0.2), late complications (OR:1.84, CI:0.78-3.98; p = 0.1) and acute urinary retention (OR:1.84, CI:0.78-3.98; p = 0.1). When the analyses were repeated and the concomitant procedures stratified into endoscopic and open/laparoscopic ones, they yielded virtually the same results | ||
520 | |a CONCLUSIONS: GL-180-W XPS PVP could be safely performed in concomitant endoscopic or open/laparoscopic surgery. These results should be taken into consideration in the counseling of the patient who might choose to undergo simultaneous procedures | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Marchioni, Michele |e verfasserin |4 aut | |
700 | 1 | |a Fasolis, Giuseppe |e verfasserin |4 aut | |
700 | 1 | |a Varvello, Francesco |e verfasserin |4 aut | |
700 | 1 | |a Ditonno, Pasquale |e verfasserin |4 aut | |
700 | 1 | |a Di Rienzo, Gaetano |e verfasserin |4 aut | |
700 | 1 | |a Greco, Francesco |e verfasserin |4 aut | |
700 | 1 | |a Altieri, Vincenzo Maria |e verfasserin |4 aut | |
700 | 1 | |a Frattini, Antonio |e verfasserin |4 aut | |
700 | 1 | |a Ferrari, Giovanni |e verfasserin |4 aut | |
700 | 1 | |a Schips, Luigi |e verfasserin |4 aut | |
700 | 1 | |a Cindolo, Luca |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica |d 1997 |g 92(2020), 4 vom: 17. Dez. |w (DE-627)NLM074810332 |x 2282-4197 |7 nnns |
773 | 1 | 8 | |g volume:92 |g year:2020 |g number:4 |g day:17 |g month:12 |
856 | 4 | 0 | |u http://dx.doi.org/10.4081/aiua.2020.4.297 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 92 |j 2020 |e 4 |b 17 |c 12 |