Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes
Copyright © Biology of Sport 2020..
The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p < 0.001). The ICCs were excellent for right- and left-leg CMJs (ICC = 0.939 and 0.941, respectively). However, an interaction was observed (p < 0.001). No differences existed for left- or right-leg when VERT was worn on the waist. However, JH was higher when VERT devices were worn on the opposite hip of the jump leg (i.e., LH>RH for right-leg CMJs; RH>LH for leftleg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:37 |
---|---|
Enthalten in: |
Biology of sport - 37(2020), 4 vom: 01. Dez., Seite 383-387 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Nickerson, Brett S [VerfasserIn] |
---|
Links: |
---|
Themen: |
Countermovement Jump |
---|
Anmerkungen: |
Date Revised 30.03.2021 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.5114/biolsport.2020.96851 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM319079120 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM319079120 | ||
003 | DE-627 | ||
005 | 20231225170708.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.5114/biolsport.2020.96851 |2 doi | |
028 | 5 | 2 | |a pubmed24n1063.xml |
035 | |a (DE-627)NLM319079120 | ||
035 | |a (NLM)33343072 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Nickerson, Brett S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 30.03.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © Biology of Sport 2020. | ||
520 | |a The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p < 0.001). The ICCs were excellent for right- and left-leg CMJs (ICC = 0.939 and 0.941, respectively). However, an interaction was observed (p < 0.001). No differences existed for left- or right-leg when VERT was worn on the waist. However, JH was higher when VERT devices were worn on the opposite hip of the jump leg (i.e., LH>RH for right-leg CMJs; RH>LH for leftleg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Countermovement Jump | |
650 | 4 | |a Measurements | |
650 | 4 | |a Performance | |
650 | 4 | |a Sensors | |
650 | 4 | |a Sports | |
700 | 1 | |a Medrano, Noel F |e verfasserin |4 aut | |
700 | 1 | |a Perez, Gabriel L |e verfasserin |4 aut | |
700 | 1 | |a Narvaez, Samantha V |e verfasserin |4 aut | |
700 | 1 | |a Carrillo, Joshua |e verfasserin |4 aut | |
700 | 1 | |a Duque, Misael |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Biology of sport |d 1991 |g 37(2020), 4 vom: 01. Dez., Seite 383-387 |w (DE-627)NLM086731742 |x 0860-021X |7 nnns |
773 | 1 | 8 | |g volume:37 |g year:2020 |g number:4 |g day:01 |g month:12 |g pages:383-387 |
856 | 4 | 0 | |u http://dx.doi.org/10.5114/biolsport.2020.96851 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 37 |j 2020 |e 4 |b 01 |c 12 |h 383-387 |