Towards a hand-held, fast, and sensitive gas chromatograph-ion mobility spectrometer for detecting volatile compounds
Ion mobility spectrometers can detect gaseous compounds at atmospheric pressure in the range of parts per trillion within a second. Due to their fast response times, high sensitivity, and limited instrumental effort, they are used in a variety of applications, especially as mobile or hand-held devices. However, most real-life samples are gas mixtures, which can pose a challenge for IMS with atmospheric pressure chemical ionization mainly due to competing gas-phase ionization processes. Therefore, we present a miniaturized drift tube IMS coupled to a compact gas chromatograph for pre-separation, built of seven bundled standard GC columns (Rtx-Volatiles, Restek GmbH) with 250 μm ID and 1.07 m in length. Such pre-separation significantly reduces chemical cross sensitivities caused by competing gas-phase ionization processes and adds orthogonality. Our miniaturized GC-IMS system is characterized with alcohols, halocarbons, and ketones as model substances, reaching detection limits down to 70 pptv with IMS averaging times of just 125 ms. It separates test mixtures of ketones and halocarbons within 180 s and 50 s, respectively. The IMS has a short drift length of 40.6 mm and reaches a high resolving power of RP = 68. Graphical abstract.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:413 |
---|---|
Enthalten in: |
Analytical and bioanalytical chemistry - 413(2021), 4 vom: 22. Feb., Seite 1009-1016 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ahrens, André [VerfasserIn] |
---|
Links: |
---|
Themen: |
Bundled GC columns |
---|
Anmerkungen: |
Date Completed 19.01.2021 Date Revised 30.03.2024 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1007/s00216-020-03059-9 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM317890190 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM317890190 | ||
003 | DE-627 | ||
005 | 20240330233917.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00216-020-03059-9 |2 doi | |
028 | 5 | 2 | |a pubmed24n1356.xml |
035 | |a (DE-627)NLM317890190 | ||
035 | |a (NLM)33222000 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ahrens, André |e verfasserin |4 aut | |
245 | 1 | 0 | |a Towards a hand-held, fast, and sensitive gas chromatograph-ion mobility spectrometer for detecting volatile compounds |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.01.2021 | ||
500 | |a Date Revised 30.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Ion mobility spectrometers can detect gaseous compounds at atmospheric pressure in the range of parts per trillion within a second. Due to their fast response times, high sensitivity, and limited instrumental effort, they are used in a variety of applications, especially as mobile or hand-held devices. However, most real-life samples are gas mixtures, which can pose a challenge for IMS with atmospheric pressure chemical ionization mainly due to competing gas-phase ionization processes. Therefore, we present a miniaturized drift tube IMS coupled to a compact gas chromatograph for pre-separation, built of seven bundled standard GC columns (Rtx-Volatiles, Restek GmbH) with 250 μm ID and 1.07 m in length. Such pre-separation significantly reduces chemical cross sensitivities caused by competing gas-phase ionization processes and adds orthogonality. Our miniaturized GC-IMS system is characterized with alcohols, halocarbons, and ketones as model substances, reaching detection limits down to 70 pptv with IMS averaging times of just 125 ms. It separates test mixtures of ketones and halocarbons within 180 s and 50 s, respectively. The IMS has a short drift length of 40.6 mm and reaches a high resolving power of RP = 68. Graphical abstract | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Bundled GC columns | |
650 | 4 | |a GC | |
650 | 4 | |a Gas chromatograph | |
650 | 4 | |a Hand-held GC-IMS | |
650 | 4 | |a IMS | |
650 | 4 | |a Ion mobility spectrometer | |
700 | 1 | |a Zimmermann, Stefan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytical and bioanalytical chemistry |d 1995 |g 413(2021), 4 vom: 22. Feb., Seite 1009-1016 |w (DE-627)NLM118176722 |x 1618-2650 |7 nnns |
773 | 1 | 8 | |g volume:413 |g year:2021 |g number:4 |g day:22 |g month:02 |g pages:1009-1016 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00216-020-03059-9 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 413 |j 2021 |e 4 |b 22 |c 02 |h 1009-1016 |