Laparoscopic partial nephrectomy using a technology of augmented reality : new vector of the development of operative urology?
AIM: to evaluate the efficiency and usefulness of augmented reality (AR) technology using HoloLens glasses for laparoscopic partial nephrectomy (LPN).
MATERIALS AND METHODS: From July to December 2019, a total of 5 patients with localized kidney cancer (cT1aN0M0) underwent AR-assisted LRP. The mean RENAL score was 6 points (5-8). Preoperatively, all patients underwent contrast-enhanced multispiral computed tomography (MSCT). The three-dimensional reconstructions of the kidney, tumor, part of the abdominal aorta with the renal artery and its branches, part of the inferior vena cava with the renal vein were segmented with color coding and connected into a single virtual 3D model, which was loaded into the program in order to display image in AR glasses. The duration of surgery and thermal ischemia, type and frequency of intraoperative complications, as well as the time spent on preparing the 3D model and the Microsoft HoloLens device were evaluated. To assess the feasibility of using AR technology intraoperatively, a Likert scale was filled out by the surgeon.
RESULTS: It took 10 (9-11) hours to prepare the model, including time to optimize the model and to set up its display and interactions. The setup of HoloLens required an average of 7.8 (5- 12) min. The total duration of the operation and the period of warm ischemia was 108 (90-120) and 20 (15-25) min, respectively, while intraoperative blood loss was 160 (110-250) ml. In all cases, a negative surgical margin was found. The surgeon who performed all the operations assessed the use of AR technology with the HoloLens device as highly beneficial in all clinical cases.
CONCLUSION: The use of AR technology with a HoloLens holographic device during LPN can lead to improved treatment outcomes.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - year:2020 |
---|---|
Enthalten in: |
Urologiia (Moscow, Russia : 1999) - (2020), 5 vom: 19. Nov., Seite 37-40 |
Sprache: |
Russisch |
---|
Beteiligte Personen: |
Gadjiev, N K [VerfasserIn] |
---|
Themen: |
Augmented reality |
---|
Anmerkungen: |
Date Completed 16.11.2020 Date Revised 25.12.2020 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM317528416 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM317528416 | ||
003 | DE-627 | ||
005 | 20231225163445.0 | ||
007 | tu | ||
008 | 231225s2020 xx ||||| 00| ||rus c | ||
028 | 5 | 2 | |a pubmed24n1058.xml |
035 | |a (DE-627)NLM317528416 | ||
035 | |a (NLM)33185344 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a rus | ||
100 | 1 | |a Gadjiev, N K |e verfasserin |4 aut | |
245 | 1 | 0 | |a Laparoscopic partial nephrectomy using a technology of augmented reality |b new vector of the development of operative urology? |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 16.11.2020 | ||
500 | |a Date Revised 25.12.2020 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a AIM: to evaluate the efficiency and usefulness of augmented reality (AR) technology using HoloLens glasses for laparoscopic partial nephrectomy (LPN) | ||
520 | |a MATERIALS AND METHODS: From July to December 2019, a total of 5 patients with localized kidney cancer (cT1aN0M0) underwent AR-assisted LRP. The mean RENAL score was 6 points (5-8). Preoperatively, all patients underwent contrast-enhanced multispiral computed tomography (MSCT). The three-dimensional reconstructions of the kidney, tumor, part of the abdominal aorta with the renal artery and its branches, part of the inferior vena cava with the renal vein were segmented with color coding and connected into a single virtual 3D model, which was loaded into the program in order to display image in AR glasses. The duration of surgery and thermal ischemia, type and frequency of intraoperative complications, as well as the time spent on preparing the 3D model and the Microsoft HoloLens device were evaluated. To assess the feasibility of using AR technology intraoperatively, a Likert scale was filled out by the surgeon | ||
520 | |a RESULTS: It took 10 (9-11) hours to prepare the model, including time to optimize the model and to set up its display and interactions. The setup of HoloLens required an average of 7.8 (5- 12) min. The total duration of the operation and the period of warm ischemia was 108 (90-120) and 20 (15-25) min, respectively, while intraoperative blood loss was 160 (110-250) ml. In all cases, a negative surgical margin was found. The surgeon who performed all the operations assessed the use of AR technology with the HoloLens device as highly beneficial in all clinical cases | ||
520 | |a CONCLUSION: The use of AR technology with a HoloLens holographic device during LPN can lead to improved treatment outcomes | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a augmented reality | |
650 | 4 | |a partial nephrectomy | |
650 | 4 | |a renal cell cancer | |
700 | 1 | |a Pogosyan, R R |e verfasserin |4 aut | |
700 | 1 | |a Ostanin, M A |e verfasserin |4 aut | |
700 | 1 | |a Petrov, S B |e verfasserin |4 aut | |
700 | 1 | |a Semenyakin, I V |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Urologiia (Moscow, Russia : 1999) |d 1999 |g (2020), 5 vom: 19. Nov., Seite 37-40 |w (DE-627)NLM110630386 |x 1728-2985 |7 nnns |
773 | 1 | 8 | |g year:2020 |g number:5 |g day:19 |g month:11 |g pages:37-40 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2020 |e 5 |b 19 |c 11 |h 37-40 |