Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer : A randomized controlled trial

OBJECTIVE: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainlesssteel fixed retainers over a 12-month study period.

METHODS: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point.

RESULTS: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events.

CONCLUSIONS: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainlesssteel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

Medienart:

E-Artikel

Erscheinungsjahr:

2020

Erschienen:

2020

Enthalten in:

Zur Gesamtaufnahme - volume:50

Enthalten in:

Korean journal of orthodontics - 50(2020), 6 vom: 25. Nov., Seite 373-382

Sprache:

Englisch

Beteiligte Personen:

Gelin, Emilie [VerfasserIn]
Seidel, Laurence [VerfasserIn]
Bruwier, Annick [VerfasserIn]
Albert, Adelin [VerfasserIn]
Charavet, Carole [VerfasserIn]

Links:

Volltext

Themen:

CAD/CAM
Digital models
Journal Article
Randomized clinical trial
Retainer

Anmerkungen:

Date Revised 18.04.2022

published: Print

Citation Status PubMed-not-MEDLINE

doi:

10.4041/kjod.2020.50.6.373

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM317127845