Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline

This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes.

Medienart:

E-Artikel

Erscheinungsjahr:

2020

Erschienen:

2020

Enthalten in:

Zur Gesamtaufnahme - volume:14

Enthalten in:

Journal of diabetes science and technology - 14(2020), 6 vom: 17. Nov., Seite 1035-1064

Sprache:

Englisch

Beteiligte Personen:

Galindo, Rodolfo J [VerfasserIn]
Umpierrez, Guillermo E [VerfasserIn]
Rushakoff, Robert J [VerfasserIn]
Basu, Ananda [VerfasserIn]
Lohnes, Suzanne [VerfasserIn]
Nichols, James H [VerfasserIn]
Spanakis, Elias K [VerfasserIn]
Espinoza, Juan [VerfasserIn]
Palermo, Nadine E [VerfasserIn]
Awadjie, Dessa Garnett [VerfasserIn]
Bak, Leigh [VerfasserIn]
Buckingham, Bruce [VerfasserIn]
Cook, Curtiss B [VerfasserIn]
Freckmann, Guido [VerfasserIn]
Heinemann, Lutz [VerfasserIn]
Hovorka, Roman [VerfasserIn]
Mathioudakis, Nestoras [VerfasserIn]
Newman, Tonya [VerfasserIn]
O'Neal, David N [VerfasserIn]
Rickert, Michaela [VerfasserIn]
Sacks, David B [VerfasserIn]
Seley, Jane Jeffrie [VerfasserIn]
Wallia, Amisha [VerfasserIn]
Shang, Trisha [VerfasserIn]
Zhang, Jennifer Y [VerfasserIn]
Han, Julia [VerfasserIn]
Klonoff, David C [VerfasserIn]

Links:

Volltext

Themen:

Automated insulin dosing
Blood Glucose
COVID-19
Continuous glucose monitor
Guideline
Hospital
Insulin
Journal Article
Practice Guideline

Anmerkungen:

Date Completed 23.11.2020

Date Revised 29.09.2021

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1177/1932296820954163

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM315559853