Simultaneous determination of sacubitrilat and fimasartan in rat plasma by a triple quad liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive mode

© 2020 John Wiley & Sons, Ltd..

An LC-tandem mass spectrometry method was developed and validated for the simultaneous quantitation of fimasartan and sacubitrilat using positive ion mode. The protein precipitation method was employed for the extraction of fimasartan, sacubitrilat and alprazolam (internal standard) from rat heparinized plasma. Baseline separation of the analytes was accomplished using an ACE-5, C18 (4.6 × 50 mm) column and gradient elution of mobile phase A (5 mm ammonium formate and 0.1% formic acid in purified water) and B (acetonitrile:methanol, 80:20; v/v). All peaks of interest were eluted within a 5-min runtime. The quantitation was achieved in the selected reaction monitoring mode. The developed method was validated as per US Food and Drug Administration guidelines and met the pre-defined acceptance criteria. The method showed linearity from 5 to 10,000 ng/mL. The accuracy/precision of intra- and inter-batch assays was 96.64%/2.05% to 109.17%/13.70% and 100.74%/3.76% to 106.39%/9.75% for fimasartan and 100.02%/1.49% to 113.80%/9.38% and 100.75%/2.31% to 108.40%/7.74% for sacubitrilat, respectively, in rat plasma. Fimasartan and sacubitrilat remained stable in rat plasma at different experimental conditions up to 21 days. The developed method was sensitive, selective and applied successfully to monitor plasma concentrations of fimasartan and sacubitrilat in an oral rat pharmacokinetic study.

Medienart:

E-Artikel

Erscheinungsjahr:

2021

Erschienen:

2021

Enthalten in:

Zur Gesamtaufnahme - volume:35

Enthalten in:

Biomedical chromatography : BMC - 35(2021), 2 vom: 01. Feb., Seite e4981

Sprache:

Englisch

Beteiligte Personen:

Giri, Poonam [VerfasserIn]
Joshi, Vipul [VerfasserIn]
Giri, Shyamkumar [VerfasserIn]
Delvadia, Prashant [VerfasserIn]
Jain, Mukul R [VerfasserIn]

Links:

Volltext

Themen:

17ERJ0MKGI
Aminobutyrates
Biphenyl Compounds
Calibration standards
Fimasartan
Journal Article
LC-MS/MS method
Lower limit of quantitation
P58222188P
Pharmacokinetic study
Prodrugs
Pyrimidines
SRM transition
Sacubitril
Tetrazoles

Anmerkungen:

Date Completed 24.05.2021

Date Revised 24.05.2021

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1002/bmc.4981

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM314686207