Bias testing, bias correction, and confounder selection using an instrumental variable model
© 2020 John Wiley & Sons Ltd..
Instrumental variable (IV) analysis can be used to address bias due to unobserved confounding when estimating the causal effect of a treatment on an outcome of interest. However, if a proposed IV is correlated with unmeasured confounders and/or weakly correlated with the treatment, the standard IV estimator may be more biased than an ordinary least squares (OLS) estimator. Several methods have been proposed that compare the bias of the IV and OLS estimators relying on the belief that measured covariates can be used as proxies for the unmeasured confounder. Despite these developments, there is lack of discussion about approaches that can be used to formally test whether the IV estimator may be less biased than the OLS estimator. Thus, we have developed a testing framework to compare the bias and a criterion to select informative measured covariates for bias comparison and regression adjustment. We also have developed a bias-correction method, which allows one to use an invalid IV to correct the bias of the OLS or IV estimator. Numerical studies demonstrate that the proposed methods perform well with realistic sample sizes.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:39 |
---|---|
Enthalten in: |
Statistics in medicine - 39(2020), 29 vom: 20. Dez., Seite 4386-4404 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Yeob Choi, Byeong [VerfasserIn] |
---|
Links: |
---|
Themen: |
Bias correction |
---|
Anmerkungen: |
Date Completed 21.06.2021 Date Revised 21.06.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/sim.8730 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM31427409X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM31427409X | ||
003 | DE-627 | ||
005 | 20231225152357.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/sim.8730 |2 doi | |
028 | 5 | 2 | |a pubmed24n1047.xml |
035 | |a (DE-627)NLM31427409X | ||
035 | |a (NLM)32854161 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Yeob Choi, Byeong |e verfasserin |4 aut | |
245 | 1 | 0 | |a Bias testing, bias correction, and confounder selection using an instrumental variable model |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 21.06.2021 | ||
500 | |a Date Revised 21.06.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2020 John Wiley & Sons Ltd. | ||
520 | |a Instrumental variable (IV) analysis can be used to address bias due to unobserved confounding when estimating the causal effect of a treatment on an outcome of interest. However, if a proposed IV is correlated with unmeasured confounders and/or weakly correlated with the treatment, the standard IV estimator may be more biased than an ordinary least squares (OLS) estimator. Several methods have been proposed that compare the bias of the IV and OLS estimators relying on the belief that measured covariates can be used as proxies for the unmeasured confounder. Despite these developments, there is lack of discussion about approaches that can be used to formally test whether the IV estimator may be less biased than the OLS estimator. Thus, we have developed a testing framework to compare the bias and a criterion to select informative measured covariates for bias comparison and regression adjustment. We also have developed a bias-correction method, which allows one to use an invalid IV to correct the bias of the OLS or IV estimator. Numerical studies demonstrate that the proposed methods perform well with realistic sample sizes | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a bias correction | |
650 | 4 | |a bias equivalence | |
650 | 4 | |a confounding bias | |
650 | 4 | |a instrumental variable | |
650 | 4 | |a ordinary least squares | |
700 | 1 | |a Fine, Jason P |e verfasserin |4 aut | |
700 | 1 | |a Alan Brookhart, M |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Statistics in medicine |d 1984 |g 39(2020), 29 vom: 20. Dez., Seite 4386-4404 |w (DE-627)NLM012664596 |x 1097-0258 |7 nnns |
773 | 1 | 8 | |g volume:39 |g year:2020 |g number:29 |g day:20 |g month:12 |g pages:4386-4404 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/sim.8730 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 39 |j 2020 |e 29 |b 20 |c 12 |h 4386-4404 |