Identification and resistance profile of bacteria isolated on stethoscopes by health care professionals : Systematic review
Copyright © 2020 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved..
BACKGROUND: Evaluate the presence of bacteria and resistance profile in stethoscopes used by health care professionals and its consequences within the hospital environment.
METHODS: It is a systematic review, in which articles indexed in the BVS, CAPES-Periódicos, Cochrane Library, PubMed, Scientific Electronic Library Online, and ScienceDirect databases were searched.
RESULTS: Twenty-two articles were selected for this study. The significant majority of professionals does not perform hygiene of the stethoscope, either due to the lack of instructions or the lack of knowledge about the contamination's risks. In addition, over these 22 articles evaluated, only 10 demonstrated that more than 50% of the analyzed samples were contaminated with some type of bacteria. Coagulase-negative Staphylococcus spp., Staphylococcus aureus, Acinetobacter spp., Pseudomonas spp., and Klebsiella pneumoniae were the most recurrent pathogens. Besides that, multiresistant strains were also isolated, highlighting resistance to Ampicillin and Clindamycin.
CONCLUSIONS: Indeed, the stethoscope is a potential disseminator of bacterial infections. The contamination is explained by the possible cross reactions that make the transmission of infectious agents possible. Cleaning before and after each auscultate is an efficient alternative to minimize these pathogens.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:49 |
---|---|
Enthalten in: |
American journal of infection control - 49(2021), 2 vom: 01. Feb., Seite 229-237 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Queiroz Júnior, José Reginaldo Alves de [VerfasserIn] |
---|
Links: |
---|
Themen: |
Cross infection |
---|
Anmerkungen: |
Date Completed 24.06.2021 Date Revised 24.06.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.ajic.2020.07.007 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM312302681 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM312302681 | ||
003 | DE-627 | ||
005 | 20231225144123.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ajic.2020.07.007 |2 doi | |
028 | 5 | 2 | |a pubmed24n1040.xml |
035 | |a (DE-627)NLM312302681 | ||
035 | |a (NLM)32653560 | ||
035 | |a (PII)S0196-6553(20)30692-1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Queiroz Júnior, José Reginaldo Alves de |e verfasserin |4 aut | |
245 | 1 | 0 | |a Identification and resistance profile of bacteria isolated on stethoscopes by health care professionals |b Systematic review |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 24.06.2021 | ||
500 | |a Date Revised 24.06.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2020 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved. | ||
520 | |a BACKGROUND: Evaluate the presence of bacteria and resistance profile in stethoscopes used by health care professionals and its consequences within the hospital environment | ||
520 | |a METHODS: It is a systematic review, in which articles indexed in the BVS, CAPES-Periódicos, Cochrane Library, PubMed, Scientific Electronic Library Online, and ScienceDirect databases were searched | ||
520 | |a RESULTS: Twenty-two articles were selected for this study. The significant majority of professionals does not perform hygiene of the stethoscope, either due to the lack of instructions or the lack of knowledge about the contamination's risks. In addition, over these 22 articles evaluated, only 10 demonstrated that more than 50% of the analyzed samples were contaminated with some type of bacteria. Coagulase-negative Staphylococcus spp., Staphylococcus aureus, Acinetobacter spp., Pseudomonas spp., and Klebsiella pneumoniae were the most recurrent pathogens. Besides that, multiresistant strains were also isolated, highlighting resistance to Ampicillin and Clindamycin | ||
520 | |a CONCLUSIONS: Indeed, the stethoscope is a potential disseminator of bacterial infections. The contamination is explained by the possible cross reactions that make the transmission of infectious agents possible. Cleaning before and after each auscultate is an efficient alternative to minimize these pathogens | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a Systematic Review | |
650 | 4 | |a Cross infection | |
650 | 4 | |a Equipment contamination | |
650 | 4 | |a Nosocomial infection | |
700 | 1 | |a Melo, Isadora Oliveira |e verfasserin |4 aut | |
700 | 1 | |a Calado, Gustavo Henrique Dos Santos |e verfasserin |4 aut | |
700 | 1 | |a Cavalcanti, Leila Raulino Camara |e verfasserin |4 aut | |
700 | 1 | |a Sobrinho, Carlos Roberto Weber |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t American journal of infection control |d 1980 |g 49(2021), 2 vom: 01. Feb., Seite 229-237 |w (DE-627)NLM012639850 |x 1527-3296 |7 nnns |
773 | 1 | 8 | |g volume:49 |g year:2021 |g number:2 |g day:01 |g month:02 |g pages:229-237 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ajic.2020.07.007 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 49 |j 2021 |e 2 |b 01 |c 02 |h 229-237 |