Double orifice mitral valve in a patient with bicuspid aortic valve and coarctation of the aorta : A rare presentation
© 2020 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd..
Double orifice mitral valve is a rare condition and may be accompanied by a bicuspid aortic valve (sometimes normal functioning) and coarctation of the aorta. Echocardiography is valuable in detecting the accompanied anomalies. Management depends on the severity of mitral valve function and the severity of associated anomalies.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:8 |
---|---|
Enthalten in: |
Clinical case reports - 8(2020), 6 vom: 21. Juni, Seite 1021-1024 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bayat, Fariba [VerfasserIn] |
---|
Links: |
---|
Themen: |
3‐dimensional echocardiography |
---|
Anmerkungen: |
Date Revised 29.03.2024 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1002/ccr3.2788 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM311557155 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM311557155 | ||
003 | DE-627 | ||
005 | 20240329233026.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/ccr3.2788 |2 doi | |
028 | 5 | 2 | |a pubmed24n1354.xml |
035 | |a (DE-627)NLM311557155 | ||
035 | |a (NLM)32577256 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bayat, Fariba |e verfasserin |4 aut | |
245 | 1 | 0 | |a Double orifice mitral valve in a patient with bicuspid aortic valve and coarctation of the aorta |b A rare presentation |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 29.03.2024 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2020 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd. | ||
520 | |a Double orifice mitral valve is a rare condition and may be accompanied by a bicuspid aortic valve (sometimes normal functioning) and coarctation of the aorta. Echocardiography is valuable in detecting the accompanied anomalies. Management depends on the severity of mitral valve function and the severity of associated anomalies | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a 3‐dimensional echocardiography | |
650 | 4 | |a bicuspid aortic valve | |
650 | 4 | |a coarctation of the aorta | |
650 | 4 | |a double orifice mitral valve | |
700 | 1 | |a Namazi, Mohammad Hasan |e verfasserin |4 aut | |
700 | 1 | |a Khani, Mohammad |e verfasserin |4 aut | |
700 | 1 | |a Shekarkhar, Shadi |e verfasserin |4 aut | |
700 | 1 | |a Fatehi, Aref |e verfasserin |4 aut | |
700 | 1 | |a Tabary, Mohammadreza |e verfasserin |4 aut | |
700 | 1 | |a Khaheshi, Isa |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical case reports |d 2013 |g 8(2020), 6 vom: 21. Juni, Seite 1021-1024 |w (DE-627)NLM234405864 |x 2050-0904 |7 nnns |
773 | 1 | 8 | |g volume:8 |g year:2020 |g number:6 |g day:21 |g month:06 |g pages:1021-1024 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/ccr3.2788 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 8 |j 2020 |e 6 |b 21 |c 06 |h 1021-1024 |