Validity and reliability of the Niño Jesús Hospital procedural sedation-analgesia scale of the under deep sedation-analgesia

Copyright © 2020 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved..

INTRODUCTION: The procedural sedation scale of the Niño Jesús Hospital (Madrid) (SSPNJH) has not been validated.

PATIENTS AND METHODS: A prospective analytical study was conducted in 2 hospitals on patients ≥ 6 months undergoing invasive procedures using sedation-analgesia with propofol or midazolam and fentanyl. All were monitored using the bispectral index (BIS). Videos were made of each procedure, which were then edited and randomised. A total of 150 videos were rated by four observers using the SSPNJH, the sedation scale of the University of Michigan (UMSS), and the Ramsay Scale (SR). These observers were blinded to the BIS, and at the time of drug administration. To assess test-retest reliability, 50 of the initial 150 randomly selected videos were re-assessed.

RESULTS: The study included a total of 65 patients. The within-observer agreement was high (ρ = 0.793). The SSPNJH gave a good interobserver reliability when compared with the UMSS (ICC = 0.88) and the SR (ICC = 0.86), and there was none with the BIS. Internal consistency was moderate (α = 0.68). Construct validity was demonstrated by changes in scores after administering sedatives (p < 0.0001). The SSPNJH had a very low correlation with the BIS (r = -0.166), and a moderate correlation with the UMSS (r = 0.497) and the SR (r = 0.405). As regards the applicability, this scale has been used in two hospitals in five different areas by four professionals of different categories.

CONCLUSIONS: The SSPNJH is valid, reliable and applicable for sedation monitoring in invasive procedures under deep sedation-analgesia in paediatric patients. The SSPNJH has worse properties than the UMSS and the SR.

Medienart:

E-Artikel

Erscheinungsjahr:

2021

Erschienen:

2021

Enthalten in:

Zur Gesamtaufnahme - volume:94

Enthalten in:

Anales de pediatria - 94(2021), 1 vom: 15. Jan., Seite 36-45

Sprache:

Spanisch

Weiterer Titel:

Validez y fiabilidad de la escala de sedación para procedimientos del Hospital Niño Jesús bajo sedoanalgesia profunda

Beteiligte Personen:

Lozano-Díaz, David [VerfasserIn]
Valdivielso Serna, Alberto [VerfasserIn]
Garrido Palomo, Ramón [VerfasserIn]
Arias-Arias, Ángel [VerfasserIn]
Tárraga López, Pedro J [VerfasserIn]
Martínez Gutiérrez, Andrés [VerfasserIn]

Links:

Volltext

Themen:

Agreement
Concordancia
Escala de sedación
Journal Article
Multicenter Study
Paediatrics
Pediatría
Procedimiento
Procedure
Sedation scale
Validación
Validation
Validation Study

Anmerkungen:

Date Completed 27.10.2021

Date Revised 27.10.2021

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1016/j.anpedi.2020.04.009

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM310389003