Evaluation of the performance of ultrasonography and 99mTc-sestamibi scintigraphy for primary hyperparathyroidism surgery
Copyright © 2020 Elsevier Masson SAS. All rights reserved..
INTRODUCTION: Minimally invasive surgery has become the standard surgical attitude in primary hyperparathyroidism. It requires precise preoperative lesion localization. The aim of the present study was to evaluate the performance of ultrasonography and 99mTc-sestamibi scintigraphy in minimally invasive surgery for primary hyperparathyroidism.
MATERIALS AND METHODS: A retrospective study included all patients managed surgically for primary hyperparathyroidism between January 2008 and November 2017 in the University Hospital of Brest (France). Two hundred and seventy-three patients underwent ultrasonography and 99mTc-sestamibi scintigraphy. Results determined intrinsic (sensitivity and specificity) and extrinsic (positive and negative predictive values) performance on per-patient and per-gland analysis. Demographic, preoperative, interventional and cure data were compared according to ultrasonography and scintigraphy results, distinguishing 3 patient groups: concordant n=156, discordant n=99, negative n=18.
RESULTS: On per-gland analysis, sensitivity was 70% for ultrasound, 74% for 99mTc-sestamibi scintigraphy and 81% for associated ultrasound-scintigraphy; positive predictive values were 89%, 91% and 96%, respectively. Gland volume and concomitant thyroid pathology rates differed significantly (both p=0.003) between the 3 imaging results groups.
CONCLUSION: The performance of associated ultrasound-99mTc-sestamibi-scintigraphy provided a positive predictive value of 96%. Combining the two techniques reduced surgical morbidity.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:137 |
---|---|
Enthalten in: |
European annals of otorhinolaryngology, head and neck diseases - 137(2020), 5 vom: 20. Nov., Seite 365-369 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
de Maissin, C [VerfasserIn] |
---|
Links: |
---|
Themen: |
971Z4W1S09 |
---|
Anmerkungen: |
Date Completed 25.10.2021 Date Revised 25.10.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.anorl.2020.03.009 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM310288258 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM310288258 | ||
003 | DE-627 | ||
005 | 20231225135754.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.anorl.2020.03.009 |2 doi | |
028 | 5 | 2 | |a pubmed24n1034.xml |
035 | |a (DE-627)NLM310288258 | ||
035 | |a (NLM)32446647 | ||
035 | |a (PII)S1879-7296(20)30085-5 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a de Maissin, C |e verfasserin |4 aut | |
245 | 1 | 0 | |a Evaluation of the performance of ultrasonography and 99mTc-sestamibi scintigraphy for primary hyperparathyroidism surgery |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.10.2021 | ||
500 | |a Date Revised 25.10.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2020 Elsevier Masson SAS. All rights reserved. | ||
520 | |a INTRODUCTION: Minimally invasive surgery has become the standard surgical attitude in primary hyperparathyroidism. It requires precise preoperative lesion localization. The aim of the present study was to evaluate the performance of ultrasonography and 99mTc-sestamibi scintigraphy in minimally invasive surgery for primary hyperparathyroidism | ||
520 | |a MATERIALS AND METHODS: A retrospective study included all patients managed surgically for primary hyperparathyroidism between January 2008 and November 2017 in the University Hospital of Brest (France). Two hundred and seventy-three patients underwent ultrasonography and 99mTc-sestamibi scintigraphy. Results determined intrinsic (sensitivity and specificity) and extrinsic (positive and negative predictive values) performance on per-patient and per-gland analysis. Demographic, preoperative, interventional and cure data were compared according to ultrasonography and scintigraphy results, distinguishing 3 patient groups: concordant n=156, discordant n=99, negative n=18 | ||
520 | |a RESULTS: On per-gland analysis, sensitivity was 70% for ultrasound, 74% for 99mTc-sestamibi scintigraphy and 81% for associated ultrasound-scintigraphy; positive predictive values were 89%, 91% and 96%, respectively. Gland volume and concomitant thyroid pathology rates differed significantly (both p=0.003) between the 3 imaging results groups | ||
520 | |a CONCLUSION: The performance of associated ultrasound-99mTc-sestamibi-scintigraphy provided a positive predictive value of 96%. Combining the two techniques reduced surgical morbidity | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Primary hyperparathyroidism | |
650 | 4 | |a Technetium Tc 99m Sestamibi | |
650 | 4 | |a Ultrasonography | |
650 | 7 | |a Radiopharmaceuticals |2 NLM | |
650 | 7 | |a Technetium Tc 99m Sestamibi |2 NLM | |
650 | 7 | |a 971Z4W1S09 |2 NLM | |
700 | 1 | |a Leclère, J-C |e verfasserin |4 aut | |
700 | 1 | |a Roudaut, N |e verfasserin |4 aut | |
700 | 1 | |a Thuillier, P |e verfasserin |4 aut | |
700 | 1 | |a Monguillon, P |e verfasserin |4 aut | |
700 | 1 | |a Marianowski, R |e verfasserin |4 aut | |
700 | 1 | |a Potard, G |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t European annals of otorhinolaryngology, head and neck diseases |d 2010 |g 137(2020), 5 vom: 20. Nov., Seite 365-369 |w (DE-627)NLM201398648 |x 1879-730X |7 nnns |
773 | 1 | 8 | |g volume:137 |g year:2020 |g number:5 |g day:20 |g month:11 |g pages:365-369 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.anorl.2020.03.009 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 137 |j 2020 |e 5 |b 20 |c 11 |h 365-369 |