Can custom 3D printed implants successfully reconstruct massive acetabular defects? A 3D-CT assessment
© 2020 Orthopaedic Research Society. Published by Wiley Periodicals LLC..
We report on the accuracy, measured with three-dimensional (3D) computed tomography (CT) postoperatively, in positioning custom 3D printed titanium components in patients with large acetabular defects. Twenty patients (13 females and 7 males) received custom-made acetabular implants between 2016 and 2018; the mean age was 66 years (SD = 11.6) and their mean body mass index was 28 (SD = 6.1). The median time to follow up was 25.5 months, range: 12 to 40 months. We describe a comparison method that uses the 3D models of CT-generated preoperative plans and the postoperative CT scans to quantify the discrepancy between planned and achieved component positions. Our primary outcome measures were the 3D-CT-measured difference between planned and achieved a component position in six degrees of freedom: center of rotation (CoR), component rotation, inclination (INC), and version (VER) of the cup. Our secondary outcome measures were: Oxford hip score, walking status, and complication rate. All components (100%) were positioned within 10 mm of planned CoR (in the three planes). Eighteen (95%) components were not rotated by more than 10° compared to the plan. Eleven (58%) components were positioned within 5° of planned cup angle (INC and VER). To date one complication has occurred, a periprosthetic fracture. This is the largest study in which postoperative 3D-CT measurements and clinical outcomes of custom-made acetabular components have been assessed. Accurate pre-op planning and the adoption of custom 3D printed implants show promising results in complex hip revision surgery.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:38 |
---|---|
Enthalten in: |
Journal of orthopaedic research : official publication of the Orthopaedic Research Society - 38(2020), 12 vom: 01. Dez., Seite 2640-2648 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Durand-Hill, Matthieu [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 02.02.2021 Date Revised 02.02.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/jor.24752 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM310098300 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM310098300 | ||
003 | DE-627 | ||
005 | 20231225135344.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/jor.24752 |2 doi | |
028 | 5 | 2 | |a pubmed24n1033.xml |
035 | |a (DE-627)NLM310098300 | ||
035 | |a (NLM)32427351 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Durand-Hill, Matthieu |e verfasserin |4 aut | |
245 | 1 | 0 | |a Can custom 3D printed implants successfully reconstruct massive acetabular defects? A 3D-CT assessment |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 02.02.2021 | ||
500 | |a Date Revised 02.02.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2020 Orthopaedic Research Society. Published by Wiley Periodicals LLC. | ||
520 | |a We report on the accuracy, measured with three-dimensional (3D) computed tomography (CT) postoperatively, in positioning custom 3D printed titanium components in patients with large acetabular defects. Twenty patients (13 females and 7 males) received custom-made acetabular implants between 2016 and 2018; the mean age was 66 years (SD = 11.6) and their mean body mass index was 28 (SD = 6.1). The median time to follow up was 25.5 months, range: 12 to 40 months. We describe a comparison method that uses the 3D models of CT-generated preoperative plans and the postoperative CT scans to quantify the discrepancy between planned and achieved component positions. Our primary outcome measures were the 3D-CT-measured difference between planned and achieved a component position in six degrees of freedom: center of rotation (CoR), component rotation, inclination (INC), and version (VER) of the cup. Our secondary outcome measures were: Oxford hip score, walking status, and complication rate. All components (100%) were positioned within 10 mm of planned CoR (in the three planes). Eighteen (95%) components were not rotated by more than 10° compared to the plan. Eleven (58%) components were positioned within 5° of planned cup angle (INC and VER). To date one complication has occurred, a periprosthetic fracture. This is the largest study in which postoperative 3D-CT measurements and clinical outcomes of custom-made acetabular components have been assessed. Accurate pre-op planning and the adoption of custom 3D printed implants show promising results in complex hip revision surgery | ||
650 | 4 | |a Clinical Trial | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a computed tomography | |
650 | 4 | |a custom 3D printed implants | |
650 | 4 | |a image analysis for component orientation | |
650 | 4 | |a paprosky acetabular defects | |
650 | 4 | |a revision Hip surgery | |
700 | 1 | |a Henckel, Johann |e verfasserin |4 aut | |
700 | 1 | |a Di Laura, Anna |e verfasserin |4 aut | |
700 | 1 | |a Hart, Alister J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of orthopaedic research : official publication of the Orthopaedic Research Society |d 1993 |g 38(2020), 12 vom: 01. Dez., Seite 2640-2648 |w (DE-627)NLM012903639 |x 1554-527X |7 nnns |
773 | 1 | 8 | |g volume:38 |g year:2020 |g number:12 |g day:01 |g month:12 |g pages:2640-2648 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/jor.24752 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 38 |j 2020 |e 12 |b 01 |c 12 |h 2640-2648 |