Acute Neurointerventions, Covid-19 and Chest-CT : SOP and Literature Review
BACKGROUND AND PURPOSE: To analyze standard operating procedures (SOP) of acute stroke imaging and interventions during COVID-19 pandemic with special emphasis on chest CT within a multimodal stroke protocol.
METHODS: A questionnaire was distributed via email to members of the Professional Organization of German Neuroradiologists (Berufsverband Deutscher Neuroradiologen e.V.).
RESULTS: Answers were received from 25 units: eleven of them acquire chest CT, three in any patient and eight, when COVID-19 is suspected due to body temperature increase, patient's history or when the latter cannot be sufficiently obtained. Preliminary data indicate a high sensitivity and moderate negative predictive value.
CONCLUSION: Different SOP reflect an uncertainty whether chest CT should be acquired as part of a multimodal stroke protocol. Accuracy of low dose chest CT cannot be determined yet. The strengths and limitations of chest CT are discussed.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:30 |
---|---|
Enthalten in: |
Clinical neuroradiology - 30(2020), 3 vom: 07. Sept., Seite 447-452 |
Sprache: |
Deutsch |
---|
Weiterer Titel: |
Notfällige Neurointerventionen, Covid-19 und Thorax-CT: SOP und Literaturübersicht |
---|
Beteiligte Personen: |
Urbach, Horst [VerfasserIn] |
---|
Links: |
---|
Themen: |
COVID-19 |
---|
Anmerkungen: |
Date Completed 09.09.2020 Date Revised 16.07.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00062-020-00911-4 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM309661455 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM309661455 | ||
003 | DE-627 | ||
005 | 20231225134416.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||ger c | ||
024 | 7 | |a 10.1007/s00062-020-00911-4 |2 doi | |
028 | 5 | 2 | |a pubmed24n1032.xml |
035 | |a (DE-627)NLM309661455 | ||
035 | |a (NLM)32382877 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a ger | ||
100 | 1 | |a Urbach, Horst |e verfasserin |4 aut | |
245 | 1 | 0 | |a Acute Neurointerventions, Covid-19 and Chest-CT |b SOP and Literature Review |
246 | 3 | 3 | |a Notfällige Neurointerventionen, Covid-19 und Thorax-CT: SOP und Literaturübersicht |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 09.09.2020 | ||
500 | |a Date Revised 16.07.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a BACKGROUND AND PURPOSE: To analyze standard operating procedures (SOP) of acute stroke imaging and interventions during COVID-19 pandemic with special emphasis on chest CT within a multimodal stroke protocol | ||
520 | |a METHODS: A questionnaire was distributed via email to members of the Professional Organization of German Neuroradiologists (Berufsverband Deutscher Neuroradiologen e.V.) | ||
520 | |a RESULTS: Answers were received from 25 units: eleven of them acquire chest CT, three in any patient and eight, when COVID-19 is suspected due to body temperature increase, patient's history or when the latter cannot be sufficiently obtained. Preliminary data indicate a high sensitivity and moderate negative predictive value | ||
520 | |a CONCLUSION: Different SOP reflect an uncertainty whether chest CT should be acquired as part of a multimodal stroke protocol. Accuracy of low dose chest CT cannot be determined yet. The strengths and limitations of chest CT are discussed | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a COVID-19 | |
650 | 4 | |a Questionnaire | |
650 | 4 | |a SARS-CoV‑2 | |
650 | 4 | |a Stroke | |
650 | 4 | |a Thrombectomy | |
700 | 1 | |a Janssen, Hendrik |e verfasserin |4 aut | |
700 | 1 | |a Linn, Jennifer |e verfasserin |4 aut | |
700 | 1 | |a Hoffmann, Titus |e verfasserin |4 aut | |
700 | 1 | |a Tritt, Stephanie |e verfasserin |4 aut | |
700 | 1 | |a Weber, Werner |e verfasserin |4 aut | |
700 | 1 | |a Wiesmann, Martin |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical neuroradiology |d 2010 |g 30(2020), 3 vom: 07. Sept., Seite 447-452 |w (DE-627)NLM195498909 |x 1869-1447 |7 nnns |
773 | 1 | 8 | |g volume:30 |g year:2020 |g number:3 |g day:07 |g month:09 |g pages:447-452 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00062-020-00911-4 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 30 |j 2020 |e 3 |b 07 |c 09 |h 447-452 |