A Prototype Framework Design for Assisting the Detection of Atrial Fibrillation Using a Generic Low-Cost Biomedical Sensor
Cardiovascular diseases are the leading cause of death around the world. As a result, low-cost biomedical sensors have been gaining importance in business and research over the last few decades. Their main benefits include their small size, light weight, portability and low power consumption. Despite these advantages, they are not generally used for clinical monitoring mainly because of their low accuracy in data acquisition. In this emerging technological context, this paper contributes by discussing a methodology to help practitioners build a prototype framework based on a low-cost commercial sensor. The resulting application consists of four modules; namely, a digitalization module whose input is an electrocardiograph signal in portable document format (PDF) or joint photographic expert group format (JPEG), a module to further process and filter the digitalized signal, a selectable data calibration module and, finally, a module implementing a classification algorithm to distinguish between individuals with normal sinus rhythms and those with atrial fibrillation. This last module employs our recently published symbolic recurrence quantification analysis (SRQA) algorithm on a time series of RR intervals. Moreover, we show that the algorithm applies to any biomedical low-cost sensor, achieving good results without requiring.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:20 |
---|---|
Enthalten in: |
Sensors (Basel, Switzerland) - 20(2020), 3 vom: 07. Feb. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Pérez-Valero, Jesús [VerfasserIn] |
---|
Links: |
---|
Themen: |
Biomedical sensor |
---|
Anmerkungen: |
Date Completed 10.11.2020 Date Revised 13.11.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.3390/s20030896 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM306405768 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM306405768 | ||
003 | DE-627 | ||
005 | 20231225123309.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/s20030896 |2 doi | |
028 | 5 | 2 | |a pubmed24n1021.xml |
035 | |a (DE-627)NLM306405768 | ||
035 | |a (NLM)32046173 | ||
035 | |a (PII)E896 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Pérez-Valero, Jesús |e verfasserin |4 aut | |
245 | 1 | 2 | |a A Prototype Framework Design for Assisting the Detection of Atrial Fibrillation Using a Generic Low-Cost Biomedical Sensor |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 10.11.2020 | ||
500 | |a Date Revised 13.11.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Cardiovascular diseases are the leading cause of death around the world. As a result, low-cost biomedical sensors have been gaining importance in business and research over the last few decades. Their main benefits include their small size, light weight, portability and low power consumption. Despite these advantages, they are not generally used for clinical monitoring mainly because of their low accuracy in data acquisition. In this emerging technological context, this paper contributes by discussing a methodology to help practitioners build a prototype framework based on a low-cost commercial sensor. The resulting application consists of four modules; namely, a digitalization module whose input is an electrocardiograph signal in portable document format (PDF) or joint photographic expert group format (JPEG), a module to further process and filter the digitalized signal, a selectable data calibration module and, finally, a module implementing a classification algorithm to distinguish between individuals with normal sinus rhythms and those with atrial fibrillation. This last module employs our recently published symbolic recurrence quantification analysis (SRQA) algorithm on a time series of RR intervals. Moreover, we show that the algorithm applies to any biomedical low-cost sensor, achieving good results without requiring | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a R peak, ECG | |
650 | 4 | |a RR interval | |
650 | 4 | |a biomedical sensor | |
650 | 4 | |a logistic regression | |
700 | 1 | |a Garcia-Sanchez, Antonio-Javier |e verfasserin |4 aut | |
700 | 1 | |a Ruiz Marín, Manuel |e verfasserin |4 aut | |
700 | 1 | |a Garcia-Haro, Joan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Sensors (Basel, Switzerland) |d 2007 |g 20(2020), 3 vom: 07. Feb. |w (DE-627)NLM187985170 |x 1424-8220 |7 nnns |
773 | 1 | 8 | |g volume:20 |g year:2020 |g number:3 |g day:07 |g month:02 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/s20030896 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 20 |j 2020 |e 3 |b 07 |c 02 |