Delayed Leukoencephalopathy : A Rare Complication after Coiling of Cerebral Aneurysms
© 2020 by American Journal of Neuroradiology..
BACKGROUND AND PURPOSE: Delayed leukoencephalopathy is a rare complication that occurs after endovascular coiling of cerebral aneurysms. We aimed to describe a clinical picture of delayed leukoencephalopathy and explore potential associations with procedural characteristics.
MATERIALS AND METHODS: We considered endovascular coiling procedures for cerebral aneurysms performed between January 2006 and December 2017 in our institution with follow-up MRIs. We used logistic regression models to estimate the ORs of delayed leukoencephalopathy for each procedural characteristic.
RESULTS: We reviewed 1754 endovascular coiling procedures of 1594 aneurysms. Sixteen of 1722 (0.9%) procedures demonstrated delayed leukoencephalopathy on follow-up FLAIR MR imaging examinations after a median period of 71.5 days (interquartile range, 30-101 days) in the form of high-signal changes in the white matter at locations remote from the coil mass. Seven patients had headaches or hemiparesis, and 9 patients were asymptomatic. All imaging-associated changes improved subsequently. We found indications suggesting an association between delayed leukoencephalopathy and the number of microcatheters used per procedure (P = .009), along with indications suggesting that these procedures required larger median volumes of contrast medium (225 versus 175 mL, OR = 5.5, P = .008) as well as a longer median fluoroscopy duration (123.6 versus 99.3 minutes, OR = 3.0, P = .06). Our data did not suggest that delayed leukoencephalopathy was associated with the number of coils (P = .57), microguidewires (P = .35), and guiding systems (P = .57).
CONCLUSIONS: Delayed leukoencephalopathy after coiling of cerebral aneurysms may have multiple etiologies such as foreign body emboli, contrast-induced encephalopathy, or hypersensitivity reaction to foreign bodies.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:41 |
---|---|
Enthalten in: |
AJNR. American journal of neuroradiology - 41(2020), 2 vom: 29. Feb., Seite 286-292 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ikemura, A [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 29.09.2020 Date Revised 01.02.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.3174/ajnr.A6386 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM305972294 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM305972294 | ||
003 | DE-627 | ||
005 | 20231225122332.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3174/ajnr.A6386 |2 doi | |
028 | 5 | 2 | |a pubmed24n1019.xml |
035 | |a (DE-627)NLM305972294 | ||
035 | |a (NLM)32001447 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ikemura, A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Delayed Leukoencephalopathy |b A Rare Complication after Coiling of Cerebral Aneurysms |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.09.2020 | ||
500 | |a Date Revised 01.02.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2020 by American Journal of Neuroradiology. | ||
520 | |a BACKGROUND AND PURPOSE: Delayed leukoencephalopathy is a rare complication that occurs after endovascular coiling of cerebral aneurysms. We aimed to describe a clinical picture of delayed leukoencephalopathy and explore potential associations with procedural characteristics | ||
520 | |a MATERIALS AND METHODS: We considered endovascular coiling procedures for cerebral aneurysms performed between January 2006 and December 2017 in our institution with follow-up MRIs. We used logistic regression models to estimate the ORs of delayed leukoencephalopathy for each procedural characteristic | ||
520 | |a RESULTS: We reviewed 1754 endovascular coiling procedures of 1594 aneurysms. Sixteen of 1722 (0.9%) procedures demonstrated delayed leukoencephalopathy on follow-up FLAIR MR imaging examinations after a median period of 71.5 days (interquartile range, 30-101 days) in the form of high-signal changes in the white matter at locations remote from the coil mass. Seven patients had headaches or hemiparesis, and 9 patients were asymptomatic. All imaging-associated changes improved subsequently. We found indications suggesting an association between delayed leukoencephalopathy and the number of microcatheters used per procedure (P = .009), along with indications suggesting that these procedures required larger median volumes of contrast medium (225 versus 175 mL, OR = 5.5, P = .008) as well as a longer median fluoroscopy duration (123.6 versus 99.3 minutes, OR = 3.0, P = .06). Our data did not suggest that delayed leukoencephalopathy was associated with the number of coils (P = .57), microguidewires (P = .35), and guiding systems (P = .57) | ||
520 | |a CONCLUSIONS: Delayed leukoencephalopathy after coiling of cerebral aneurysms may have multiple etiologies such as foreign body emboli, contrast-induced encephalopathy, or hypersensitivity reaction to foreign bodies | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Ishibashi, T |e verfasserin |4 aut | |
700 | 1 | |a Otani, K |e verfasserin |4 aut | |
700 | 1 | |a Yuki, I |e verfasserin |4 aut | |
700 | 1 | |a Kodama, T |e verfasserin |4 aut | |
700 | 1 | |a Kan, I |e verfasserin |4 aut | |
700 | 1 | |a Kato, N |e verfasserin |4 aut | |
700 | 1 | |a Murayama, Y |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t AJNR. American journal of neuroradiology |d 1990 |g 41(2020), 2 vom: 29. Feb., Seite 286-292 |w (DE-627)NLM012664189 |x 1936-959X |7 nnns |
773 | 1 | 8 | |g volume:41 |g year:2020 |g number:2 |g day:29 |g month:02 |g pages:286-292 |
856 | 4 | 0 | |u http://dx.doi.org/10.3174/ajnr.A6386 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 41 |j 2020 |e 2 |b 29 |c 02 |h 286-292 |