Corneal Light Scatter After Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty in Descemet Endothelial Thickness Comparison Trial : A Randomized Controlled Trial
PURPOSE: To compare the degree of corneal light scatter as measured by densitometry in ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) and Descemet Membrane Endothelial Keratoplasty (DMEK) in the Descemet endothelial thickness comparison trial.
METHODS: This was a prespecified secondary analysis of the Descemet endothelial thickness comparison trial, which was a prospective, randomized controlled trial. Subjects with isolated endothelial dysfunction were enrolled and were randomized to either UT-DSAEK or DMEK. Corneal opacity was quantitatively measured by Pentacam densitometry (OCULUS) at 3, 6, and 12 months.
RESULTS: Fifty eyes of 38 patients were enrolled at the Casey Eye Institute at Oregon Health & Science University and the Byers Eye Institute at Stanford University. Corneal densitometry for the anterior and posterior layers improved in both UT-DSAEK and DMEK after surgery. The decrease was more pronounced in the posterior layer for both groups. However, there was no difference in the degree of corneal light scatter between UT-DSAEK and DMEK at postoperative month 12, and no difference in change in densitometry was observed between the 2 arms from baseline to month 12.
CONCLUSIONS: Both UT-DSAEK and DMEK experience an improvement in the degree of corneal light scatter after surgery. However, there was no difference in densitometry between the 2 groups at month 12. Therefore, other factors such as higher order aberrations in the posterior cornea rather than stromal-stromal interface haze mediate the superior visual outcomes in DMEK compared with UT-DSAEK.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:39 |
---|---|
Enthalten in: |
Cornea - 39(2020), 6 vom: 15. Juni, Seite 691-696 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hirabayashi, Kristin E [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 25.03.2021 Date Revised 06.06.2021 published: Print Citation Status MEDLINE |
---|
doi: |
10.1097/ICO.0000000000002256 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM305384422 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM305384422 | ||
003 | DE-627 | ||
005 | 20231225121047.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1097/ICO.0000000000002256 |2 doi | |
028 | 5 | 2 | |a pubmed24n1017.xml |
035 | |a (DE-627)NLM305384422 | ||
035 | |a (NLM)31939923 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hirabayashi, Kristin E |e verfasserin |4 aut | |
245 | 1 | 0 | |a Corneal Light Scatter After Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty in Descemet Endothelial Thickness Comparison Trial |b A Randomized Controlled Trial |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.03.2021 | ||
500 | |a Date Revised 06.06.2021 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a PURPOSE: To compare the degree of corneal light scatter as measured by densitometry in ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) and Descemet Membrane Endothelial Keratoplasty (DMEK) in the Descemet endothelial thickness comparison trial | ||
520 | |a METHODS: This was a prespecified secondary analysis of the Descemet endothelial thickness comparison trial, which was a prospective, randomized controlled trial. Subjects with isolated endothelial dysfunction were enrolled and were randomized to either UT-DSAEK or DMEK. Corneal opacity was quantitatively measured by Pentacam densitometry (OCULUS) at 3, 6, and 12 months | ||
520 | |a RESULTS: Fifty eyes of 38 patients were enrolled at the Casey Eye Institute at Oregon Health & Science University and the Byers Eye Institute at Stanford University. Corneal densitometry for the anterior and posterior layers improved in both UT-DSAEK and DMEK after surgery. The decrease was more pronounced in the posterior layer for both groups. However, there was no difference in the degree of corneal light scatter between UT-DSAEK and DMEK at postoperative month 12, and no difference in change in densitometry was observed between the 2 arms from baseline to month 12 | ||
520 | |a CONCLUSIONS: Both UT-DSAEK and DMEK experience an improvement in the degree of corneal light scatter after surgery. However, there was no difference in densitometry between the 2 groups at month 12. Therefore, other factors such as higher order aberrations in the posterior cornea rather than stromal-stromal interface haze mediate the superior visual outcomes in DMEK compared with UT-DSAEK | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Multicenter Study | |
650 | 4 | |a Randomized Controlled Trial | |
700 | 1 | |a Chamberlain, Winston |e verfasserin |4 aut | |
700 | 1 | |a Rose-Nussbaumer, Jennifer |e verfasserin |4 aut | |
700 | 1 | |a Austin, Ariana |e verfasserin |4 aut | |
700 | 1 | |a Stell, Laurel |e verfasserin |4 aut | |
700 | 1 | |a Lin, Charles C |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Cornea |d 1989 |g 39(2020), 6 vom: 15. Juni, Seite 691-696 |w (DE-627)NLM012620696 |x 1536-4798 |7 nnns |
773 | 1 | 8 | |g volume:39 |g year:2020 |g number:6 |g day:15 |g month:06 |g pages:691-696 |
856 | 4 | 0 | |u http://dx.doi.org/10.1097/ICO.0000000000002256 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 39 |j 2020 |e 6 |b 15 |c 06 |h 691-696 |