Impact of Transcatheter Aortic Valve Implantation on Kidney Function
BACKGROUND: Chronic kidney disease (CKD) is frequently present in patients with aortic valve disease. Decreased kidney perfusion as a consequence of reduced cardiac output may contribute to renal dysfunction in this setting.
OBJECTIVE: Given the potential reversibility of kidney hypoperfusion after valve repair, this study aimed to analyze the impact of percutaneous transcatheter aortic valve implantation (TAVI) on kidney function.
METHODS: We performed a retrospective analysis of 233 consecutive patients who underwent TAVI in a single center between November 2008 and May 2016. We assessed three groups according to their baseline estimated glomerular filtration rate (eGFR) (mL/min/1.73 m2): Group 1 with eGFR ≥ 60; Group 2 with 30 ≤ eGFR < 60; and Group 3 with eGFR < 30. We analyzed the eGFR one month and one year after TAVI in these three groups, using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula to calculate it.
RESULTS: Patients from Group 1 had a progressive decline in eGFR one year after the TAVI procedure (p < 0.001 vs. pre-TAVI). In Group 2 patients, the mean eGFR increased one month after TAVI and continued to grow after one year (p = 0.001 vs. pre-TAVI). The same occurred in Group 3, with the mean eGFR increasing from 24.4 ± 5.1 mL/min/1.73 m2 before TAVI to 38.4 ± 18.8 mL/min/1.73 m2 one year after TAVI (p = 0.012).
CONCLUSIONS: For patients with moderate-to-severe CKD, kidney function improved one year after the TAVI procedure. This outcome is probably due to better kidney perfusion post-procedure. We believe that when evaluating patients that might need TAVI, this 'reversibility of CKD effect' should be considered.
Errataetall: |
CommentIn: Arq Bras Cardiol. 2019 Dec;113(6):1112-1113. - PMID 31800686 |
---|---|
Medienart: |
E-Artikel |
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:113 |
---|---|
Enthalten in: |
Arquivos brasileiros de cardiologia - 113(2019), 6 vom: 22. Dez., Seite 1104-1111 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Calça, Rita [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 19.05.2020 Date Revised 19.05.2020 published: Print CommentIn: Arq Bras Cardiol. 2019 Dec;113(6):1112-1113. - PMID 31800686 Citation Status MEDLINE |
---|
doi: |
10.36660/abc.20180356 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM303540745 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM303540745 | ||
003 | DE-627 | ||
005 | 20231225113035.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.36660/abc.20180356 |2 doi | |
028 | 5 | 2 | |a pubmed24n1011.xml |
035 | |a (DE-627)NLM303540745 | ||
035 | |a (NLM)31751440 | ||
035 | |a (PII)S0066-782X2019001201104 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Calça, Rita |e verfasserin |4 aut | |
245 | 1 | 0 | |a Impact of Transcatheter Aortic Valve Implantation on Kidney Function |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.05.2020 | ||
500 | |a Date Revised 19.05.2020 | ||
500 | |a published: Print | ||
500 | |a CommentIn: Arq Bras Cardiol. 2019 Dec;113(6):1112-1113. - PMID 31800686 | ||
500 | |a Citation Status MEDLINE | ||
520 | |a BACKGROUND: Chronic kidney disease (CKD) is frequently present in patients with aortic valve disease. Decreased kidney perfusion as a consequence of reduced cardiac output may contribute to renal dysfunction in this setting | ||
520 | |a OBJECTIVE: Given the potential reversibility of kidney hypoperfusion after valve repair, this study aimed to analyze the impact of percutaneous transcatheter aortic valve implantation (TAVI) on kidney function | ||
520 | |a METHODS: We performed a retrospective analysis of 233 consecutive patients who underwent TAVI in a single center between November 2008 and May 2016. We assessed three groups according to their baseline estimated glomerular filtration rate (eGFR) (mL/min/1.73 m2): Group 1 with eGFR ≥ 60; Group 2 with 30 ≤ eGFR < 60; and Group 3 with eGFR < 30. We analyzed the eGFR one month and one year after TAVI in these three groups, using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula to calculate it | ||
520 | |a RESULTS: Patients from Group 1 had a progressive decline in eGFR one year after the TAVI procedure (p < 0.001 vs. pre-TAVI). In Group 2 patients, the mean eGFR increased one month after TAVI and continued to grow after one year (p = 0.001 vs. pre-TAVI). The same occurred in Group 3, with the mean eGFR increasing from 24.4 ± 5.1 mL/min/1.73 m2 before TAVI to 38.4 ± 18.8 mL/min/1.73 m2 one year after TAVI (p = 0.012) | ||
520 | |a CONCLUSIONS: For patients with moderate-to-severe CKD, kidney function improved one year after the TAVI procedure. This outcome is probably due to better kidney perfusion post-procedure. We believe that when evaluating patients that might need TAVI, this 'reversibility of CKD effect' should be considered | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Teles, Rui C |e verfasserin |4 aut | |
700 | 1 | |a Branco, Patrícia |e verfasserin |4 aut | |
700 | 1 | |a Gaspar, Augusta |e verfasserin |4 aut | |
700 | 1 | |a Brito, João |e verfasserin |4 aut | |
700 | 1 | |a Nolasco, Tiago |e verfasserin |4 aut | |
700 | 1 | |a Almeida, Manuel D |e verfasserin |4 aut | |
700 | 1 | |a Neves, José P |e verfasserin |4 aut | |
700 | 1 | |a Mendes, Miguel |e verfasserin |4 aut | |
700 | 1 | |a Machado, Domingos S |e verfasserin |4 aut | |
700 | 1 | |a Weigert, André |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Arquivos brasileiros de cardiologia |d 1950 |g 113(2019), 6 vom: 22. Dez., Seite 1104-1111 |w (DE-627)NLM000272981 |x 1678-4170 |7 nnns |
773 | 1 | 8 | |g volume:113 |g year:2019 |g number:6 |g day:22 |g month:12 |g pages:1104-1111 |
856 | 4 | 0 | |u http://dx.doi.org/10.36660/abc.20180356 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 113 |j 2019 |e 6 |b 22 |c 12 |h 1104-1111 |