Continuous Glucose Monitoring : Review of an Innovation in Diabetes Management
Crown Copyright © 2019. Published by Elsevier Inc. All rights reserved..
Most continuous glucose monitors (CGM) provide interstitial fluid glucose trends, which reflect blood glucose trends with alarms and alerts to prevent hypoglycemia and provide better glycemic control. CGM used in conjunction with insulin pumps has changed the management of patients with insulin-dependent diabetes, mainly type 1 diabetes. CGM technology prevents the need for frequent blood glucose testing, which is often cumbersome for patients, providing them with a better alternative. CGM technology is underprescribed and therefore advantage should be taken of this technology to provide better hemoglobin A1c (HbA1c) control and decrease incidence of diabetic complications. CGM is particularly useful in patients with hypoglycemia unawareness and nocturnal hypoglycemia. CGM is currently not approved in pregnant patients, in critically ill patients and patients on dialysis. Research suggests that the benefits certainly outweigh the limitations of this technology. This review article focuses on the technical and clinical use of continuous glucose monitoring and sensor-integrated pump technology.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:358 |
---|---|
Enthalten in: |
The American journal of the medical sciences - 358(2019), 5 vom: 10. Nov., Seite 332-339 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Mian, Zainab [VerfasserIn] |
---|
Links: |
---|
Themen: |
Blood Glucose |
---|
Anmerkungen: |
Date Completed 17.03.2020 Date Revised 17.03.2020 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.amjms.2019.07.003 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM300125933 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM300125933 | ||
003 | DE-627 | ||
005 | 20231225101837.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.amjms.2019.07.003 |2 doi | |
028 | 5 | 2 | |a pubmed24n1000.xml |
035 | |a (DE-627)NLM300125933 | ||
035 | |a (NLM)31402042 | ||
035 | |a (PII)S0002-9629(19)30267-8 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Mian, Zainab |e verfasserin |4 aut | |
245 | 1 | 0 | |a Continuous Glucose Monitoring |b Review of an Innovation in Diabetes Management |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 17.03.2020 | ||
500 | |a Date Revised 17.03.2020 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Crown Copyright © 2019. Published by Elsevier Inc. All rights reserved. | ||
520 | |a Most continuous glucose monitors (CGM) provide interstitial fluid glucose trends, which reflect blood glucose trends with alarms and alerts to prevent hypoglycemia and provide better glycemic control. CGM used in conjunction with insulin pumps has changed the management of patients with insulin-dependent diabetes, mainly type 1 diabetes. CGM technology prevents the need for frequent blood glucose testing, which is often cumbersome for patients, providing them with a better alternative. CGM technology is underprescribed and therefore advantage should be taken of this technology to provide better hemoglobin A1c (HbA1c) control and decrease incidence of diabetic complications. CGM is particularly useful in patients with hypoglycemia unawareness and nocturnal hypoglycemia. CGM is currently not approved in pregnant patients, in critically ill patients and patients on dialysis. Research suggests that the benefits certainly outweigh the limitations of this technology. This review article focuses on the technical and clinical use of continuous glucose monitoring and sensor-integrated pump technology | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a Continuous glucose monitoring | |
650 | 4 | |a Fingerstick blood glucose testing | |
650 | 4 | |a Hyperglycemia | |
650 | 4 | |a Hypoglycemia | |
650 | 4 | |a Sensor integrated pump technology | |
650 | 7 | |a Blood Glucose |2 NLM | |
650 | 7 | |a Hypoglycemic Agents |2 NLM | |
650 | 7 | |a Insulin |2 NLM | |
700 | 1 | |a Hermayer, Kathie L |e verfasserin |4 aut | |
700 | 1 | |a Jenkins, Alicia |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The American journal of the medical sciences |d 1945 |g 358(2019), 5 vom: 10. Nov., Seite 332-339 |w (DE-627)NLM000046051 |x 1538-2990 |7 nnns |
773 | 1 | 8 | |g volume:358 |g year:2019 |g number:5 |g day:10 |g month:11 |g pages:332-339 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.amjms.2019.07.003 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 358 |j 2019 |e 5 |b 10 |c 11 |h 332-339 |