How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey
BACKGROUND: Combination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies.
AIMS: The aim of this study was to assess contact-force (CF) implementation into clinical practice.
METHODS: A 36-question electronic form was sent to 105 electrophysiologists (EP) including some general questions concerning the practice of catheter atrial fibrillation ablation and items concerning the parameters used for CF-guided ablation.
RESULTS: Answers from 98 EP were collected (93% response rate). The CF-catheters used were Smart Touch, Biosense (52%), Tacticath, Saint-Jude Medical (12%), or both (27%) and no CF (9%). The power applied on the left atrial (LA) anterior (LAAW) and posterior (LAPW) wall was, respectively, 26-34 W (for 73% of the EP) and below 25 W (88% of the EP). Forty percent of the Visitag® users mostly used the nominal parameters. Seventy-five percent of the users did not use automatic display of the impedance drop. For the Tacticath users, 57% used a target value of 400 gs on the LAAW and 300 to 400 gs on the LAPW. Lesion Size Index was exceptionally used.
CONCLUSIONS: The parameters used for CF-guided ablation are widely variable among the different operators. Further prospective studies are needed to validate the targets for automatic annotation of the RF applications.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
Journal of arrhythmia - 35(2019), 2 vom: 09. Apr., Seite 238-243 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bun, Sok-Sithikun [VerfasserIn] |
---|
Links: |
---|
Themen: |
Ablation parameters |
---|
Anmerkungen: |
Date Revised 06.10.2023 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1002/joa3.12165 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM296281786 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM296281786 | ||
003 | DE-627 | ||
005 | 20231225085512.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/joa3.12165 |2 doi | |
028 | 5 | 2 | |a pubmed24n0987.xml |
035 | |a (DE-627)NLM296281786 | ||
035 | |a (NLM)31007788 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bun, Sok-Sithikun |e verfasserin |4 aut | |
245 | 1 | 0 | |a How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 06.10.2023 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a BACKGROUND: Combination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies | ||
520 | |a AIMS: The aim of this study was to assess contact-force (CF) implementation into clinical practice | ||
520 | |a METHODS: A 36-question electronic form was sent to 105 electrophysiologists (EP) including some general questions concerning the practice of catheter atrial fibrillation ablation and items concerning the parameters used for CF-guided ablation | ||
520 | |a RESULTS: Answers from 98 EP were collected (93% response rate). The CF-catheters used were Smart Touch, Biosense (52%), Tacticath, Saint-Jude Medical (12%), or both (27%) and no CF (9%). The power applied on the left atrial (LA) anterior (LAAW) and posterior (LAPW) wall was, respectively, 26-34 W (for 73% of the EP) and below 25 W (88% of the EP). Forty percent of the Visitag® users mostly used the nominal parameters. Seventy-five percent of the users did not use automatic display of the impedance drop. For the Tacticath users, 57% used a target value of 400 gs on the LAAW and 300 to 400 gs on the LAPW. Lesion Size Index was exceptionally used | ||
520 | |a CONCLUSIONS: The parameters used for CF-guided ablation are widely variable among the different operators. Further prospective studies are needed to validate the targets for automatic annotation of the RF applications | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a ablation parameters | |
650 | 4 | |a contact‐force catheters | |
650 | 4 | |a radiofrequency ablation | |
700 | 1 | |a Lațcu, Decebal Gabriel |e verfasserin |4 aut | |
700 | 1 | |a Taghji, Philippe |e verfasserin |4 aut | |
700 | 1 | |a Anselme, Frederic |e verfasserin |4 aut | |
700 | 1 | |a Boveda, Serge |e verfasserin |4 aut | |
700 | 1 | |a Cebron, Jean-Pierre |e verfasserin |4 aut | |
700 | 1 | |a Defaye, Pascal |e verfasserin |4 aut | |
700 | 1 | |a Deharo, Jean-Claude |e verfasserin |4 aut | |
700 | 1 | |a Fauchier, Laurent |e verfasserin |4 aut | |
700 | 1 | |a Gandjbakhch, Estelle |e verfasserin |4 aut | |
700 | 1 | |a Gras, Daniel |e verfasserin |4 aut | |
700 | 1 | |a Klug, Didier |e verfasserin |4 aut | |
700 | 1 | |a Mansourati, Jacques |e verfasserin |4 aut | |
700 | 1 | |a Marijon, Eloi |e verfasserin |4 aut | |
700 | 1 | |a Maury, Jean-Philippe |e verfasserin |4 aut | |
700 | 1 | |a Squara, Fabien |e verfasserin |4 aut | |
700 | 1 | |a Saoudi, Nadir |e verfasserin |4 aut | |
700 | 1 | |a Taïeb, Jérôme |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of arrhythmia |d 2014 |g 35(2019), 2 vom: 09. Apr., Seite 238-243 |w (DE-627)NLM245858962 |x 1880-4276 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2019 |g number:2 |g day:09 |g month:04 |g pages:238-243 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/joa3.12165 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 35 |j 2019 |e 2 |b 09 |c 04 |h 238-243 |