Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU
In critical illness hypo-and hyperglycemia have a negative influence on patient outcome. Continuous glucose monitoring (CGM) could help in early detection of hypo-and hyperglycemia. A requirement for these new methods is an acceptable accuracy and precision in clinical practice. In this pilot study we prospectively evaluated the accuracy and precision of two CGM sensors (subcutaneous sensor: Sentrino®, Medtronic and intravasal sensor: Glucoclear®, Edwards) in 20 patients on a cardio-surgical ICU in a head to head comparison. CGM data were recorded for up to 48 h and values were compared with blood-gas-analysis (BGA) values, analysed with Bland-Altman-plots and color-coded surveillance error-grids. Shown are means ± standard deviations. In total 270/255 intravasal/subcutaneous pairs with BGA-values were analysed. The average runtime of the sensors was 28.4 ± 6.4 h. Correlation with BGA values yielded a correlation coefficient of 0.76 (subcutaneous sensor) and 0.92 (intravasal sensor). The Bland Altman Plots revealed an accuracy of 2.5 mg/dl, and a precision of + 43.0 mg/dl to - 38.0 mg/dl (subcutaneous sensor) and an accuracy of - 6.0 mg/dl, and a precision of + 12.4 mg/dl to - 24.4 mg/dl (intravasal sensor). No severe hypoglycemic event, defined as BG level below 40 mg/dl, occurred during treatment. Both sensors showed good accuracy in comparison to the BGA values, however they differ regarding precision, which in case of the subcutaneous sensor is considerable high.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:33 |
---|---|
Enthalten in: |
Journal of clinical monitoring and computing - 33(2019), 5 vom: 12. Okt., Seite 895-901 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Punke, M A [VerfasserIn] |
---|
Links: |
---|
Themen: |
Blood Glucose |
---|
Anmerkungen: |
Date Completed 29.05.2020 Date Revised 29.05.2020 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s10877-018-0221-5 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM290537282 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM290537282 | ||
003 | DE-627 | ||
005 | 20231225064943.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s10877-018-0221-5 |2 doi | |
028 | 5 | 2 | |a pubmed24n0968.xml |
035 | |a (DE-627)NLM290537282 | ||
035 | |a (NLM)30421152 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Punke, M A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.05.2020 | ||
500 | |a Date Revised 29.05.2020 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a In critical illness hypo-and hyperglycemia have a negative influence on patient outcome. Continuous glucose monitoring (CGM) could help in early detection of hypo-and hyperglycemia. A requirement for these new methods is an acceptable accuracy and precision in clinical practice. In this pilot study we prospectively evaluated the accuracy and precision of two CGM sensors (subcutaneous sensor: Sentrino®, Medtronic and intravasal sensor: Glucoclear®, Edwards) in 20 patients on a cardio-surgical ICU in a head to head comparison. CGM data were recorded for up to 48 h and values were compared with blood-gas-analysis (BGA) values, analysed with Bland-Altman-plots and color-coded surveillance error-grids. Shown are means ± standard deviations. In total 270/255 intravasal/subcutaneous pairs with BGA-values were analysed. The average runtime of the sensors was 28.4 ± 6.4 h. Correlation with BGA values yielded a correlation coefficient of 0.76 (subcutaneous sensor) and 0.92 (intravasal sensor). The Bland Altman Plots revealed an accuracy of 2.5 mg/dl, and a precision of + 43.0 mg/dl to - 38.0 mg/dl (subcutaneous sensor) and an accuracy of - 6.0 mg/dl, and a precision of + 12.4 mg/dl to - 24.4 mg/dl (intravasal sensor). No severe hypoglycemic event, defined as BG level below 40 mg/dl, occurred during treatment. Both sensors showed good accuracy in comparison to the BGA values, however they differ regarding precision, which in case of the subcutaneous sensor is considerable high | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Blood glucose | |
650 | 4 | |a Cardio-surgical patients | |
650 | 4 | |a Continuous glucose monitoring | |
650 | 4 | |a Sensors | |
650 | 7 | |a Blood Glucose |2 NLM | |
650 | 7 | |a Insulin |2 NLM | |
650 | 7 | |a Glucose Oxidase |2 NLM | |
650 | 7 | |a EC 1.1.3.4 |2 NLM | |
700 | 1 | |a Decker, C |e verfasserin |4 aut | |
700 | 1 | |a Petzoldt, M |e verfasserin |4 aut | |
700 | 1 | |a Reuter, D A |e verfasserin |4 aut | |
700 | 1 | |a Wodack, K H |e verfasserin |4 aut | |
700 | 1 | |a Reichenspurner, H |e verfasserin |4 aut | |
700 | 1 | |a Kubik, M |e verfasserin |4 aut | |
700 | 1 | |a Kluge, S |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical monitoring and computing |d 1998 |g 33(2019), 5 vom: 12. Okt., Seite 895-901 |w (DE-627)NLM095818405 |x 1573-2614 |7 nnns |
773 | 1 | 8 | |g volume:33 |g year:2019 |g number:5 |g day:12 |g month:10 |g pages:895-901 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s10877-018-0221-5 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 33 |j 2019 |e 5 |b 12 |c 10 |h 895-901 |