Parameter extraction method for the twisted pair cable with rectangular connectors
Cables play an important role in transmitting energy and information. In this article, in order to obtain the S-parameters of the special twisted pair cable with rectangular connectors, a de-embedding method of the transmission matrix is proposed to deal with the two adapters ends of the cable. According to the frequency-dependent RLGC(f) model, the cable characteristics are extracted in the frequency range of 10 MHz to 200 MHz through conventional and modified methods respectively. The frequency-domain analysis shows that the inherent capacity of modified method can decrease the errors especially due to the discontinuities of hyperbolic functions. This research supplies an advantageous modelling approach for the cable to improve its robustness against disturbances in the S-parameters measurement that cannot be decreased with the calibration procedure.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
PloS one - 13(2018), 10 vom: 05., Seite e0205072 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Fang, Wei [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 25.03.2019 Date Revised 25.03.2019 published: Electronic-eCollection Citation Status MEDLINE |
---|
doi: |
10.1371/journal.pone.0205072 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM289252873 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM289252873 | ||
003 | DE-627 | ||
005 | 20231225062138.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1371/journal.pone.0205072 |2 doi | |
028 | 5 | 2 | |a pubmed24n0964.xml |
035 | |a (DE-627)NLM289252873 | ||
035 | |a (NLM)30289924 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Fang, Wei |e verfasserin |4 aut | |
245 | 1 | 0 | |a Parameter extraction method for the twisted pair cable with rectangular connectors |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.03.2019 | ||
500 | |a Date Revised 25.03.2019 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Cables play an important role in transmitting energy and information. In this article, in order to obtain the S-parameters of the special twisted pair cable with rectangular connectors, a de-embedding method of the transmission matrix is proposed to deal with the two adapters ends of the cable. According to the frequency-dependent RLGC(f) model, the cable characteristics are extracted in the frequency range of 10 MHz to 200 MHz through conventional and modified methods respectively. The frequency-domain analysis shows that the inherent capacity of modified method can decrease the errors especially due to the discontinuities of hyperbolic functions. This research supplies an advantageous modelling approach for the cable to improve its robustness against disturbances in the S-parameters measurement that cannot be decreased with the calibration procedure | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Ren, Yongfeng |e verfasserin |4 aut | |
700 | 1 | |a Liu, Xin |e verfasserin |4 aut | |
700 | 1 | |a Jiao, Xinquan |e verfasserin |4 aut | |
700 | 1 | |a Chu, Chengqun |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t PloS one |d 2006 |g 13(2018), 10 vom: 05., Seite e0205072 |w (DE-627)NLM167327399 |x 1932-6203 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2018 |g number:10 |g day:05 |g pages:e0205072 |
856 | 4 | 0 | |u http://dx.doi.org/10.1371/journal.pone.0205072 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||