Study on the Design of Explosive (HNS) Content Analysis System Based on THz Spectrum Monomer
HNS quantitative spectral analysis can not be achieved with the existing infrared Fourier transform spectrometer. As a common monomer explosive concerned, quick identification and quantitative analysis of the substance is important, so it is necessary to research and design a HNS detection system based on THz spectroscopy. Transmissive mode was used in the system to calculate the content of HNS. Electro-optic modulator module was introduced in the system, in order to achieve steady and rapid static scanning optical path. In the experiments HNS characteristic absorption peak positions were acquired. With this basis, combined air absorption characteristics of the wavelength band and spectrum data correlation expression was obtained, thus more characteristic wavelengths selected were determined. According to Beer-Lambert law, the function expression of HNS content and coefficient formula were presented. In the experiment different content of HNS sample powder was obtained with chemical configuration method with the content at the standard level. It made HNS sample powder into HNS Sample slice for all HNS samples, and it carried out HNS content testing with MINI-Z Terahertz spectroscopy and the system. Experimental results show that the results of the two methods are similar in the range of 0.10% to 50.00% for HNS content. Their error is less than 5.0% compared to the standard value, and the system has better linearity.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2016 |
---|---|
Erschienen: |
2016 |
Enthalten in: |
Zur Gesamtaufnahme - volume:36 |
---|---|
Enthalten in: |
Guang pu xue yu guang pu fen xi = Guang pu - 36(2016), 11 vom: 29. Nov., Seite 3506-9 |
Sprache: |
Chinesisch |
---|
Beteiligte Personen: |
Li, Jing [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 26.09.2018 Date Revised 26.09.2018 published: Print Citation Status PubMed-not-MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM28836001X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM28836001X | ||
003 | DE-627 | ||
005 | 20231225060119.0 | ||
007 | tu | ||
008 | 231225s2016 xx ||||| 00| ||chi c | ||
028 | 5 | 2 | |a pubmed24n0961.xml |
035 | |a (DE-627)NLM28836001X | ||
035 | |a (NLM)30198656 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a chi | ||
100 | 1 | |a Li, Jing |e verfasserin |4 aut | |
245 | 1 | 0 | |a Study on the Design of Explosive (HNS) Content Analysis System Based on THz Spectrum Monomer |
264 | 1 | |c 2016 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 26.09.2018 | ||
500 | |a Date Revised 26.09.2018 | ||
500 | |a published: Print | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a HNS quantitative spectral analysis can not be achieved with the existing infrared Fourier transform spectrometer. As a common monomer explosive concerned, quick identification and quantitative analysis of the substance is important, so it is necessary to research and design a HNS detection system based on THz spectroscopy. Transmissive mode was used in the system to calculate the content of HNS. Electro-optic modulator module was introduced in the system, in order to achieve steady and rapid static scanning optical path. In the experiments HNS characteristic absorption peak positions were acquired. With this basis, combined air absorption characteristics of the wavelength band and spectrum data correlation expression was obtained, thus more characteristic wavelengths selected were determined. According to Beer-Lambert law, the function expression of HNS content and coefficient formula were presented. In the experiment different content of HNS sample powder was obtained with chemical configuration method with the content at the standard level. It made HNS sample powder into HNS Sample slice for all HNS samples, and it carried out HNS content testing with MINI-Z Terahertz spectroscopy and the system. Experimental results show that the results of the two methods are similar in the range of 0.10% to 50.00% for HNS content. Their error is less than 5.0% compared to the standard value, and the system has better linearity | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a English Abstract | |
700 | 1 | |a Lu, Xu-tao |e verfasserin |4 aut | |
700 | 1 | |a Lü, Hai-feng |e verfasserin |4 aut | |
700 | 1 | |a Sun, Yun-qiang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Guang pu xue yu guang pu fen xi = Guang pu |d 1997 |g 36(2016), 11 vom: 29. Nov., Seite 3506-9 |w (DE-627)NLM09368360X |x 1000-0593 |7 nnns |
773 | 1 | 8 | |g volume:36 |g year:2016 |g number:11 |g day:29 |g month:11 |g pages:3506-9 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 36 |j 2016 |e 11 |b 29 |c 11 |h 3506-9 |