Microstructured prealloyed Titanium-Nickel powder as a novel nonenzymatic hydrogen peroxide sensor
Copyright © 2018 Elsevier Inc. All rights reserved..
At present, commercial pure Titanium (Ti) and microstructured pre-alloyed Titanium-Nickel (TiNi) powders are employed as a sensitive electrochemical hydrogen peroxide (H2O2) sensor. Surface characterization of these materials are performed by x-ray diffraction (XRD) and scanning electron microscopy (SEM). The electrochemical characterization is achieved via cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) on Ti and TiNi modified glassy carbon electrode (GCE). The electrochemical behavior of H2O2 at the pure Ti/GCE and microstructure pre-alloyed TiNi/GCE are studied by CV in 0.1 M phosphate buffer solution (PBS) containing as the supporting electrolyte. In addition, CA is employed for the determination of H2O2 at the applied potential of 0 V vs. Ag/AgCl. The sensor has a linear response range of 0.5-17.5 mM with a sensitivity of 280 µA mM-1 cm-2. Moreover, the limit of detection (LOD) and limit of quantification (LOQ) are 0.5 µM and 1.7 µM, respectively. The electrochemical sensor exhibits fast and selective responses to H2O2 concentration. The applicability of the sensor is checked using a hair coloring as a real sample with satisfactory results.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:530 |
---|---|
Enthalten in: |
Journal of colloid and interface science - 530(2018) vom: 15. Nov., Seite 353-360 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Çelik Kazıcı, Hilal [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 12.11.2018 Date Revised 10.12.2019 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.jcis.2018.06.079 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM286247550 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM286247550 | ||
003 | DE-627 | ||
005 | 20231225051245.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jcis.2018.06.079 |2 doi | |
028 | 5 | 2 | |a pubmed24n0954.xml |
035 | |a (DE-627)NLM286247550 | ||
035 | |a (NLM)29982028 | ||
035 | |a (PII)S0021-9797(18)30727-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Çelik Kazıcı, Hilal |e verfasserin |4 aut | |
245 | 1 | 0 | |a Microstructured prealloyed Titanium-Nickel powder as a novel nonenzymatic hydrogen peroxide sensor |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.11.2018 | ||
500 | |a Date Revised 10.12.2019 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2018 Elsevier Inc. All rights reserved. | ||
520 | |a At present, commercial pure Titanium (Ti) and microstructured pre-alloyed Titanium-Nickel (TiNi) powders are employed as a sensitive electrochemical hydrogen peroxide (H2O2) sensor. Surface characterization of these materials are performed by x-ray diffraction (XRD) and scanning electron microscopy (SEM). The electrochemical characterization is achieved via cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) on Ti and TiNi modified glassy carbon electrode (GCE). The electrochemical behavior of H2O2 at the pure Ti/GCE and microstructure pre-alloyed TiNi/GCE are studied by CV in 0.1 M phosphate buffer solution (PBS) containing as the supporting electrolyte. In addition, CA is employed for the determination of H2O2 at the applied potential of 0 V vs. Ag/AgCl. The sensor has a linear response range of 0.5-17.5 mM with a sensitivity of 280 µA mM-1 cm-2. Moreover, the limit of detection (LOD) and limit of quantification (LOQ) are 0.5 µM and 1.7 µM, respectively. The electrochemical sensor exhibits fast and selective responses to H2O2 concentration. The applicability of the sensor is checked using a hair coloring as a real sample with satisfactory results | ||
650 | 4 | |a Evaluation Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Alloy | |
650 | 4 | |a Amperometry | |
650 | 4 | |a Hair coloring | |
650 | 4 | |a Hydrogen peroxide | |
650 | 4 | |a Microstructured TiNi | |
650 | 4 | |a Sensor | |
650 | 7 | |a Hair Dyes |2 NLM | |
650 | 7 | |a Powders |2 NLM | |
650 | 7 | |a titanium nickelide |2 NLM | |
650 | 7 | |a 12035-60-8 |2 NLM | |
650 | 7 | |a Nickel |2 NLM | |
650 | 7 | |a 7OV03QG267 |2 NLM | |
650 | 7 | |a Hydrogen Peroxide |2 NLM | |
650 | 7 | |a BBX060AN9V |2 NLM | |
650 | 7 | |a Titanium |2 NLM | |
650 | 7 | |a D1JT611TNE |2 NLM | |
700 | 1 | |a Caglar, Aykut |e verfasserin |4 aut | |
700 | 1 | |a Aydogmus, Tarik |e verfasserin |4 aut | |
700 | 1 | |a Aktas, Nahit |e verfasserin |4 aut | |
700 | 1 | |a Kivrak, Hilal |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of colloid and interface science |d 1966 |g 530(2018) vom: 15. Nov., Seite 353-360 |w (DE-627)NLM041487958 |x 1095-7103 |7 nnns |
773 | 1 | 8 | |g volume:530 |g year:2018 |g day:15 |g month:11 |g pages:353-360 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jcis.2018.06.079 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 530 |j 2018 |b 15 |c 11 |h 353-360 |