Arthroscopic Suprapectoral Biceps Tenodesis With Tenodesis Screw
There are many methods for long head of the biceps tendon (LHBT) tenodesis, but a consensus on a superior method has yet to be met. In this article, we introduce a method for arthroscopic suprapectoral biceps tenodesis using a tenodesis screw in the bicipital tunnel. The intra-articular portion of the biceps tendon is transected. The subdeltoid space is then viewed via a lateral portal, and the tendon is mobilized from the bicipital tunnel. The tendon is retrieved through the anterior portal, and 5 whipstitch passes and a second distal stitch are placed. Three of the suture tails are passed through the tenodesis screwdriver, and the tendon is maneuvered to the previously reamed bone socket located 1.5 cm superior to the pec tendon, just inferior to the bicipital groove. Once the tenodesis screw is fixated in sufficient bone stock, 5 alternating half hitches reinforce the construct by creating a closed loop through the screw. This described technique allows full visualization of the LHBT dissection and tenodesis throughout the procedure. Additionally, this technique provides a method to incorporate whipstitching with an arthroscopic tenodesis screw to provide additional strength to tendon fixation.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:7 |
---|---|
Enthalten in: |
Arthroscopy techniques - 7(2018), 5 vom: 31. Mai, Seite e417-e422 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Forsythe, Brian [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 01.10.2020 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.eats.2017.10.015 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM285134388 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM285134388 | ||
003 | DE-627 | ||
005 | 20231225044743.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.eats.2017.10.015 |2 doi | |
028 | 5 | 2 | |a pubmed24n0950.xml |
035 | |a (DE-627)NLM285134388 | ||
035 | |a (NLM)29868413 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Forsythe, Brian |e verfasserin |4 aut | |
245 | 1 | 0 | |a Arthroscopic Suprapectoral Biceps Tenodesis With Tenodesis Screw |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 01.10.2020 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a There are many methods for long head of the biceps tendon (LHBT) tenodesis, but a consensus on a superior method has yet to be met. In this article, we introduce a method for arthroscopic suprapectoral biceps tenodesis using a tenodesis screw in the bicipital tunnel. The intra-articular portion of the biceps tendon is transected. The subdeltoid space is then viewed via a lateral portal, and the tendon is mobilized from the bicipital tunnel. The tendon is retrieved through the anterior portal, and 5 whipstitch passes and a second distal stitch are placed. Three of the suture tails are passed through the tenodesis screwdriver, and the tendon is maneuvered to the previously reamed bone socket located 1.5 cm superior to the pec tendon, just inferior to the bicipital groove. Once the tenodesis screw is fixated in sufficient bone stock, 5 alternating half hitches reinforce the construct by creating a closed loop through the screw. This described technique allows full visualization of the LHBT dissection and tenodesis throughout the procedure. Additionally, this technique provides a method to incorporate whipstitching with an arthroscopic tenodesis screw to provide additional strength to tendon fixation | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Zuke, William A |e verfasserin |4 aut | |
700 | 1 | |a Puzzitiello, Richard N |e verfasserin |4 aut | |
700 | 1 | |a Romeo, Anthony A |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Arthroscopy techniques |d 2012 |g 7(2018), 5 vom: 31. Mai, Seite e417-e422 |w (DE-627)NLM228346576 |x 2212-6287 |7 nnns |
773 | 1 | 8 | |g volume:7 |g year:2018 |g number:5 |g day:31 |g month:05 |g pages:e417-e422 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.eats.2017.10.015 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 7 |j 2018 |e 5 |b 31 |c 05 |h e417-e422 |