A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO2-NH2 nanocomposites modified glassy carbon electrode
Copyright © 2018 Elsevier B.V. All rights reserved..
Herein, (3-aminopropyl)triethoxysilane functionalized cerium (IV) oxide (CeO2-NH2) supported Pd nanoparticles were synthesized. The nanocomposites were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and High-resolution transmission electron microscopy (HRTEM). The PdCeO2-NH2 showed better electrocatalytic response to the reduction of H2O2 than CeO2-NH2. The fabricated sensor exhibited two linear responses to the reduction of H2O2. The first one was from 0.001 to 3.276 mM with 0.47 μM of a limit of detection (LOD) (S/N = 3) and excellent sensitivity of 440.72 μA mM-1 cm-2 and the second one was from 3.276 to 17.500 mM with the sensitivity of 852.65 μA mM-1 cm-2 in the optimum conductions. Also, the sensor exhibited 91% of electrocatalytic activity toward H2O2 after having been used for 30 days and the reproducibility was also satisfactory. The sensor response to H2O2 was not affected by ascorbic acid, fructose, glycine, dopamine, arginine, mannose, glucose, uric acid, Mg+2, Ca+2, and phenylalanine at the studied potential. Also, the fabricated sensor was used to determine H2O2 in milk samples. The results show that the constructed sensor can be a promising devise for the determination of H2O2 in real samples.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:90 |
---|---|
Enthalten in: |
Materials science & engineering. C, Materials for biological applications - 90(2018) vom: 01. Sept., Seite 454-460 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Guler, Muhammet [VerfasserIn] |
---|
Links: |
---|
Themen: |
7440-44-0 |
---|
Anmerkungen: |
Date Completed 01.10.2018 Date Revised 01.10.2018 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.msec.2018.04.084 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM284983535 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM284983535 | ||
003 | DE-627 | ||
005 | 20231225044359.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.msec.2018.04.084 |2 doi | |
028 | 5 | 2 | |a pubmed24n0949.xml |
035 | |a (DE-627)NLM284983535 | ||
035 | |a (NLM)29853112 | ||
035 | |a (PII)S0928-4931(17)32503-1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Guler, Muhammet |e verfasserin |4 aut | |
245 | 1 | 2 | |a A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO2-NH2 nanocomposites modified glassy carbon electrode |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 01.10.2018 | ||
500 | |a Date Revised 01.10.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2018 Elsevier B.V. All rights reserved. | ||
520 | |a Herein, (3-aminopropyl)triethoxysilane functionalized cerium (IV) oxide (CeO2-NH2) supported Pd nanoparticles were synthesized. The nanocomposites were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and High-resolution transmission electron microscopy (HRTEM). The PdCeO2-NH2 showed better electrocatalytic response to the reduction of H2O2 than CeO2-NH2. The fabricated sensor exhibited two linear responses to the reduction of H2O2. The first one was from 0.001 to 3.276 mM with 0.47 μM of a limit of detection (LOD) (S/N = 3) and excellent sensitivity of 440.72 μA mM-1 cm-2 and the second one was from 3.276 to 17.500 mM with the sensitivity of 852.65 μA mM-1 cm-2 in the optimum conductions. Also, the sensor exhibited 91% of electrocatalytic activity toward H2O2 after having been used for 30 days and the reproducibility was also satisfactory. The sensor response to H2O2 was not affected by ascorbic acid, fructose, glycine, dopamine, arginine, mannose, glucose, uric acid, Mg+2, Ca+2, and phenylalanine at the studied potential. Also, the fabricated sensor was used to determine H2O2 in milk samples. The results show that the constructed sensor can be a promising devise for the determination of H2O2 in real samples | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Amine functionalized cerium (IV) oxide | |
650 | 4 | |a Hydrogen peroxide | |
650 | 4 | |a Pd nanoparticles | |
650 | 4 | |a Sensor | |
650 | 7 | |a Carbon |2 NLM | |
650 | 7 | |a 7440-44-0 |2 NLM | |
650 | 7 | |a Graphite |2 NLM | |
650 | 7 | |a 7782-42-5 |2 NLM | |
650 | 7 | |a Hydrogen Peroxide |2 NLM | |
650 | 7 | |a BBX060AN9V |2 NLM | |
700 | 1 | |a Turkoglu, Vedat |e verfasserin |4 aut | |
700 | 1 | |a Kivrak, Arif |e verfasserin |4 aut | |
700 | 1 | |a Karahan, Fatih |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Materials science & engineering. C, Materials for biological applications |d 2008 |g 90(2018) vom: 01. Sept., Seite 454-460 |w (DE-627)NLM207175020 |x 1873-0191 |7 nnns |
773 | 1 | 8 | |g volume:90 |g year:2018 |g day:01 |g month:09 |g pages:454-460 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.msec.2018.04.084 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 90 |j 2018 |b 01 |c 09 |h 454-460 |