Perceptually Regulated Exercise Test Allows Determination of V˙O2max and Ventilatory Threshold But Not Respiratory Compensation Point In Trained Runners
© Georg Thieme Verlag KG Stuttgart · New York..
This study aimed to investigate the differences in maximal oxygen uptake (V̇O2max) and submaximal thresholds between a standard graded exercise test (GXT) and a perceptually regulated graded exercise test (PRGXT) in trained runners. Eleven well-trained middle- to long-distance runners performed both tests in a randomized order. PRGXT used incremental "clamps" of rating of perceived exertion (RPE) over 10×1-min stages on an automated treadmill equipped with a sonar sensor allowing them to change their running speed instantly and in a natural way. GXT used fixed 1 km.h-1 increment every minute. Ventilatory threshold (VT) and respiratory compensation point (RCP) were determined using ventilatory equivalents. No differences were found in V̇O2max (68.0 (5.3) vs. 69.5 (5.9) ml·min-1·kg-1, p=0.243), minute ventilation (V̇E) (159.4 (35.0) vs. 162.4 (33.7) l·min-1, p=0.175), heart rate (HR) (188.4 (6.9) vs. 190.7 (5.2) bpm, p=0.254) and speed (21.0 (1.7) vs. 21.1 (2.3) km·h-1, p=0.761) between GXT and PRGXT. At VT, there were no significant differences between GXT and PRGXT for any outcome variables. For 8 of 11 subjects, it was not possible to determine RCP from ventilatory equivalent in PRGXT. GXT appears more relevant for a comprehensive gas analysis in trained runners.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:39 |
---|---|
Enthalten in: |
International journal of sports medicine - 39(2018), 4 vom: 01. Apr., Seite 304-313 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Truong, Perrine [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 16.04.2018 Date Revised 16.04.2018 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1055/s-0043-122741 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM281333084 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM281333084 | ||
003 | DE-627 | ||
005 | 20231225031405.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1055/s-0043-122741 |2 doi | |
028 | 5 | 2 | |a pubmed24n0937.xml |
035 | |a (DE-627)NLM281333084 | ||
035 | |a (NLM)29475209 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Truong, Perrine |e verfasserin |4 aut | |
245 | 1 | 0 | |a Perceptually Regulated Exercise Test Allows Determination of V˙O2max and Ventilatory Threshold But Not Respiratory Compensation Point In Trained Runners |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 16.04.2018 | ||
500 | |a Date Revised 16.04.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © Georg Thieme Verlag KG Stuttgart · New York. | ||
520 | |a This study aimed to investigate the differences in maximal oxygen uptake (V̇O2max) and submaximal thresholds between a standard graded exercise test (GXT) and a perceptually regulated graded exercise test (PRGXT) in trained runners. Eleven well-trained middle- to long-distance runners performed both tests in a randomized order. PRGXT used incremental "clamps" of rating of perceived exertion (RPE) over 10×1-min stages on an automated treadmill equipped with a sonar sensor allowing them to change their running speed instantly and in a natural way. GXT used fixed 1 km.h-1 increment every minute. Ventilatory threshold (VT) and respiratory compensation point (RCP) were determined using ventilatory equivalents. No differences were found in V̇O2max (68.0 (5.3) vs. 69.5 (5.9) ml·min-1·kg-1, p=0.243), minute ventilation (V̇E) (159.4 (35.0) vs. 162.4 (33.7) l·min-1, p=0.175), heart rate (HR) (188.4 (6.9) vs. 190.7 (5.2) bpm, p=0.254) and speed (21.0 (1.7) vs. 21.1 (2.3) km·h-1, p=0.761) between GXT and PRGXT. At VT, there were no significant differences between GXT and PRGXT for any outcome variables. For 8 of 11 subjects, it was not possible to determine RCP from ventilatory equivalent in PRGXT. GXT appears more relevant for a comprehensive gas analysis in trained runners | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Millet, Gregoire P |e verfasserin |4 aut | |
700 | 1 | |a Gojanovic, Boris |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International journal of sports medicine |d 1989 |g 39(2018), 4 vom: 01. Apr., Seite 304-313 |w (DE-627)NLM012994103 |x 1439-3964 |7 nnns |
773 | 1 | 8 | |g volume:39 |g year:2018 |g number:4 |g day:01 |g month:04 |g pages:304-313 |
856 | 4 | 0 | |u http://dx.doi.org/10.1055/s-0043-122741 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 39 |j 2018 |e 4 |b 01 |c 04 |h 304-313 |