A melamine based molecularly imprinted sensor for the determination of 8-hydroxydeoxyguanosine in human urine
Copyright © 2017 Elsevier B.V. All rights reserved..
A sensitive and facile molecular imprinted sensor has been fabricated using edge plane pyrolytic graphite (EPPG) for the determination of an important oxidative DNA damage product, 8-hydroxydeoxyguanosine (8-OHdG). The molecularly imprinted polymer film was fabricated by electropolymerization of melamine in the presence of 8-OHdG, on glutaraldehyde/poly 1,5-diaminonaphthalene modified EPPG. The imprinted sensor surface was characterized by using Field Emission Scanning Electron Microscopy, Electron Impedance Spectroscopy, Cyclic Voltammetry, Square Wave Voltammetry and UV-visible spectroscopy. The calibration response was linear over a concentration range of 20×10-9-3×10-6M of 8-OHdG with sensitivity and limit of detection (3σ/b) as 10.59µM/µA and 3×10-9M respectively. The common metabolites in urine, like uric acid, ascorbic acid, xanthine, hypoxanthine do not interfere up to 100-fold concentration. The imprinted sensor is also successfully employed for the determination of 8-OHdG in human urine sample of a renal failure patient.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:166 |
---|---|
Enthalten in: |
Talanta - 166(2017) vom: 01. Mai, Seite 215-222 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Kumar, Neeraj [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 05.09.2018 Date Revised 10.12.2019 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.talanta.2017.01.058 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM269077677 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM269077677 | ||
003 | DE-627 | ||
005 | 20231224223851.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.talanta.2017.01.058 |2 doi | |
028 | 5 | 2 | |a pubmed24n0896.xml |
035 | |a (DE-627)NLM269077677 | ||
035 | |a (NLM)28213225 | ||
035 | |a (PII)S0039-9140(17)30168-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Kumar, Neeraj |e verfasserin |4 aut | |
245 | 1 | 2 | |a A melamine based molecularly imprinted sensor for the determination of 8-hydroxydeoxyguanosine in human urine |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 05.09.2018 | ||
500 | |a Date Revised 10.12.2019 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2017 Elsevier B.V. All rights reserved. | ||
520 | |a A sensitive and facile molecular imprinted sensor has been fabricated using edge plane pyrolytic graphite (EPPG) for the determination of an important oxidative DNA damage product, 8-hydroxydeoxyguanosine (8-OHdG). The molecularly imprinted polymer film was fabricated by electropolymerization of melamine in the presence of 8-OHdG, on glutaraldehyde/poly 1,5-diaminonaphthalene modified EPPG. The imprinted sensor surface was characterized by using Field Emission Scanning Electron Microscopy, Electron Impedance Spectroscopy, Cyclic Voltammetry, Square Wave Voltammetry and UV-visible spectroscopy. The calibration response was linear over a concentration range of 20×10-9-3×10-6M of 8-OHdG with sensitivity and limit of detection (3σ/b) as 10.59µM/µA and 3×10-9M respectively. The common metabolites in urine, like uric acid, ascorbic acid, xanthine, hypoxanthine do not interfere up to 100-fold concentration. The imprinted sensor is also successfully employed for the determination of 8-OHdG in human urine sample of a renal failure patient | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a 1,5-Diaminonaphthalene | |
650 | 4 | |a 8-Hydroxydeoxyguanosine | |
650 | 4 | |a Glutaraldehyde | |
650 | 4 | |a Human urine | |
650 | 4 | |a Melamine | |
650 | 4 | |a Molecular imprinted technique | |
650 | 7 | |a Polymers |2 NLM | |
650 | 7 | |a Triazines |2 NLM | |
650 | 7 | |a 8-Hydroxy-2'-Deoxyguanosine |2 NLM | |
650 | 7 | |a 88847-89-6 |2 NLM | |
650 | 7 | |a Deoxyguanosine |2 NLM | |
650 | 7 | |a G9481N71RO |2 NLM | |
650 | 7 | |a melamine |2 NLM | |
650 | 7 | |a N3GP2YSD88 |2 NLM | |
700 | 1 | |a Rosy |e verfasserin |4 aut | |
700 | 1 | |a Goyal, Rajendra N |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Talanta |d 1966 |g 166(2017) vom: 01. Mai, Seite 215-222 |w (DE-627)NLM114409137 |x 1873-3573 |7 nnns |
773 | 1 | 8 | |g volume:166 |g year:2017 |g day:01 |g month:05 |g pages:215-222 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.talanta.2017.01.058 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 166 |j 2017 |b 01 |c 05 |h 215-222 |