Multi-centre field evaluation of the performance of the Trinity Biotech Uni-Gold HIV 1/2 rapid test as a first-line screening assay for gay and bisexual men compared with 4th generation laboratory immunoassays

Copyright © 2016 Elsevier B.V. All rights reserved..

BACKGROUND: The Trinity Biotech Uni-Gold HIV test (Uni-Gold) is often used as a supplementary rapid test in testing algorithms.

OBJECTIVE: To evaluate the operational performance of the Uni-Gold as a first-line screening test among gay and bisexual men (GBM) in a setting where 4th generation HIV laboratory assays are routinely used.

STUDY DESIGN: We compared the performance of Uni-Gold with conventional HIV serology conducted in parallel among GBM attending 22 testing sites. Sensitivity was calculated separately for acute and established infection, defined using 4th generation screening Ag/Ab immunoassay (EIA) and Western blot results. Previous HIV testing history and results of supplementary 3rd generation HIV Ab EIA, and p24 antigen EIA were used to further characterise cases of acute infection.

RESULTS: Of 10,793 specimens tested with Uni-Gold and conventional serology, 94 (0.90%, 95%CI:0.70-1.07) were confirmed as HIV-positive by conventional serology, and 37 (39.4%) were classified as acute infection. Uni-Gold sensitivity was 81.9% overall (77/94, 95%CI:72.6-89.1); 56.8% for acute infection (21/37, 95%CI:39.5-72.9) and 98.2% for established infection (56/57, 95%CI:90.6-100.0). Of 17 false non-reactive Uni-Gold results, 16 were acute infections, and of these seven were p24 antigen reactive but antibody negative. Uni-Gold specificity was 99.9% (10,692/10,699, 95%CI:99.9-100.0), PPV was 91.7% (95%CI:83.6-96.6) and NPV was 99.8% (95%CI:99.7-99.9), respectively.

CONCLUSIONS: In this population, Uni-Gold had good specificity and sensitivity was high for established infections when compared to 4th generation laboratory assays, however sensitivity was lower in acute infections. Where rapid tests are used in populations with a high proportion of acute infections, additional testing strategies are needed to detect acute infections.

Medienart:

E-Artikel

Erscheinungsjahr:

2017

Erschienen:

2017

Enthalten in:

Zur Gesamtaufnahme - volume:86

Enthalten in:

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology - 86(2017) vom: 05. Jan., Seite 46-51

Sprache:

Englisch

Beteiligte Personen:

Keen, P [VerfasserIn]
Conway, D P [VerfasserIn]
Cunningham, P [VerfasserIn]
McNulty, A [VerfasserIn]
Couldwell, D L [VerfasserIn]
Davies, S C [VerfasserIn]
Smith, D E [VerfasserIn]
Gray, J [VerfasserIn]
Holt, M [VerfasserIn]
O'Connor, C C [VerfasserIn]
Read, P [VerfasserIn]
Callander, D [VerfasserIn]
Prestage, G [VerfasserIn]
Guy, R [VerfasserIn]

Links:

Volltext

Themen:

3rd generation immunoassay
4th generation immunoassay
Acute HIV infection
Comparative Study
Evaluation Study
Journal Article
Multicenter Study
P24 antigen
Performance
Rapid HIV test

Anmerkungen:

Date Completed 03.01.2018

Date Revised 10.12.2019

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1016/j.jcv.2016.11.006

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM26679016X