OBJECTIVE: To determine the incidence and risk factors of phlebitis associated to the care of peripheral vascular catheters (PVC).
METHOD: Prospective cohort study at the Central University Hospital of Asturias (Spain). A total of 178PVC were observed daily until their extraction. The incidence of phlebitis was measured using the Visual Infusion Phlebitis Scale, that distinguishes between gradei (possible phlebitis) andii (phlebitis). The independent diagnoses of phlebitis made by staff nurses were also collected. Finally, data about the insertion and the care of the PVC was also obtained. The incidence of phlebitis and the validity of the diagnoses made by staff nurses were calculated and the risk factors of phlebitis were determined by means of logistic regression.
RESULTS: 5.6% of the PVC presented phlebitis, 21.3% possible phlebitis and 11.2% had phlebitis according to nurses' criteria. The staff nurses had a sensitivity of 100%, a specificity of 94% and a positive predictive value of 50% in the diagnosis of phlebitis. After adjusting for potential confounders, the use of an extension tube as an accessory of the PVC was an independent predictor of phlebitis (odds ratio: 4.8; P=.04), but a PVC size of 22/24 gauges was associated with lower phlebitis incidence (odds ratio: 0.2; P=.02).
CONCLUSIONS: Clinical phlebitis assessment is difficult because the agreement for phlebitis diagnosis is low. To minimize the incidence of phlebitis would be recommended to choose the smallest PVC size possible and to avoid using an extension tube as an accessory of the PVC.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:27 |
---|---|
Enthalten in: |
Enfermeria clinica - 27(2017), 2 vom: 01. März, Seite 79-86 |
Sprache: |
Englisch |
---|
Weiterer Titel: |
Incidencia y factores de riesgo de flebitis asociadas a catéteres venosos periféricos |
---|
Beteiligte Personen: |
Arias-Fernández, Loreto [VerfasserIn] |
---|
Links: |
---|
Themen: |
Cateterización venosa periférica |
---|
Anmerkungen: |
Date Completed 15.06.2018 Date Revised 15.06.2018 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.enfcli.2016.07.008 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM264447921 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM264447921 | ||
003 | DE-627 | ||
005 | 20231224210117.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.enfcli.2016.07.008 |2 doi | |
028 | 5 | 2 | |a pubmed24n0881.xml |
035 | |a (DE-627)NLM264447921 | ||
035 | |a (NLM)27640931 | ||
035 | |a (PII)S1130-8621(16)30096-1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Arias-Fernández, Loreto |e verfasserin |4 aut | |
245 | 1 | 0 | |a Incidence and risk factors of phlebitis associated to peripheral intravenous catheters |
246 | 3 | 3 | |a Incidencia y factores de riesgo de flebitis asociadas a catéteres venosos periféricos |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 15.06.2018 | ||
500 | |a Date Revised 15.06.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2016 Elsevier España, S.L.U. All rights reserved. | ||
520 | |a OBJECTIVE: To determine the incidence and risk factors of phlebitis associated to the care of peripheral vascular catheters (PVC) | ||
520 | |a METHOD: Prospective cohort study at the Central University Hospital of Asturias (Spain). A total of 178PVC were observed daily until their extraction. The incidence of phlebitis was measured using the Visual Infusion Phlebitis Scale, that distinguishes between gradei (possible phlebitis) andii (phlebitis). The independent diagnoses of phlebitis made by staff nurses were also collected. Finally, data about the insertion and the care of the PVC was also obtained. The incidence of phlebitis and the validity of the diagnoses made by staff nurses were calculated and the risk factors of phlebitis were determined by means of logistic regression | ||
520 | |a RESULTS: 5.6% of the PVC presented phlebitis, 21.3% possible phlebitis and 11.2% had phlebitis according to nurses' criteria. The staff nurses had a sensitivity of 100%, a specificity of 94% and a positive predictive value of 50% in the diagnosis of phlebitis. After adjusting for potential confounders, the use of an extension tube as an accessory of the PVC was an independent predictor of phlebitis (odds ratio: 4.8; P=.04), but a PVC size of 22/24 gauges was associated with lower phlebitis incidence (odds ratio: 0.2; P=.02) | ||
520 | |a CONCLUSIONS: Clinical phlebitis assessment is difficult because the agreement for phlebitis diagnosis is low. To minimize the incidence of phlebitis would be recommended to choose the smallest PVC size possible and to avoid using an extension tube as an accessory of the PVC | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Cateterización venosa periférica | |
650 | 4 | |a Enfermería | |
650 | 4 | |a Factores de riesgo | |
650 | 4 | |a Flebitis | |
650 | 4 | |a Incidence | |
650 | 4 | |a Incidencia | |
650 | 4 | |a Nursing | |
650 | 4 | |a Peripheral venous catheterization | |
650 | 4 | |a Phlebitis | |
650 | 4 | |a Risk factors | |
700 | 1 | |a Suérez-Mier, Belén |e verfasserin |4 aut | |
700 | 1 | |a Martínez-Ortega, María Del Carmen |e verfasserin |4 aut | |
700 | 1 | |a Lana, Alberto |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Enfermeria clinica |d 2007 |g 27(2017), 2 vom: 01. März, Seite 79-86 |w (DE-627)NLM171950070 |x 1579-2013 |7 nnns |
773 | 1 | 8 | |g volume:27 |g year:2017 |g number:2 |g day:01 |g month:03 |g pages:79-86 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.enfcli.2016.07.008 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 27 |j 2017 |e 2 |b 01 |c 03 |h 79-86 |