Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use
The objective of this study is to evaluate the safety and efficacy of a new transcutaneous bone-conduction implant (BCI BB) in patients with conductive and mixed hearing loss or with single-sided deafness (SSD), 1 year after surgical implantation. The study design is multicentric prospective, intra-subject measurements. Each subject is his/her own control. The setting is nine university hospitals: 7 French and 2 Belgian. Sixteen subjects with conductive or mixed hearing loss with bone-conduction hearing thresholds under the upper limit of 45 dB HL for each frequency from 500 to 4000 Hz, and 12 subjects with SSD (contralateral hearing within normal range) were enrolled in the study. All subjects were older than 18 years. The intervention is rehabilitative. The main outcome measure is the evaluation of skin safety, audiological measurements, benefit, and satisfaction questionnaires with a 1-year follow up. Skin safety was rated as good or very good. For the mixed or conductive hearing loss groups, the average functional gain (at 500 Hz, 1, 2, 4 kHz) was 26.1 dB HL (SD 13.7), and mean percentage of speech recognition in quiet at 65 dB was 95 % (vs 74 % unaided). In 5/6 SSD subjects, values of SRT in noise were lower with BB. Questionnaires revealed patient benefit and satisfaction. The transcutaneous BCI is very well tolerated at 1-year follow up, improves audiometric thresholds and intelligibility for speech in quiet and noise, and gives satisfaction to both patients with mixed and conductive hearing loss and patients with SSD.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:274 |
---|---|
Enthalten in: |
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery - 274(2017), 4 vom: 30. Apr., Seite 1835-1851 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Schmerber, Sébastien [VerfasserIn] |
---|
Links: |
---|
Themen: |
Bonebridge |
---|
Anmerkungen: |
Date Completed 12.05.2017 Date Revised 02.12.2018 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00405-016-4228-6 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM262974061 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM262974061 | ||
003 | DE-627 | ||
005 | 20231224202850.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00405-016-4228-6 |2 doi | |
028 | 5 | 2 | |a pubmed24n0876.xml |
035 | |a (DE-627)NLM262974061 | ||
035 | |a (NLM)27475796 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Schmerber, Sébastien |e verfasserin |4 aut | |
245 | 1 | 0 | |a Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.05.2017 | ||
500 | |a Date Revised 02.12.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The objective of this study is to evaluate the safety and efficacy of a new transcutaneous bone-conduction implant (BCI BB) in patients with conductive and mixed hearing loss or with single-sided deafness (SSD), 1 year after surgical implantation. The study design is multicentric prospective, intra-subject measurements. Each subject is his/her own control. The setting is nine university hospitals: 7 French and 2 Belgian. Sixteen subjects with conductive or mixed hearing loss with bone-conduction hearing thresholds under the upper limit of 45 dB HL for each frequency from 500 to 4000 Hz, and 12 subjects with SSD (contralateral hearing within normal range) were enrolled in the study. All subjects were older than 18 years. The intervention is rehabilitative. The main outcome measure is the evaluation of skin safety, audiological measurements, benefit, and satisfaction questionnaires with a 1-year follow up. Skin safety was rated as good or very good. For the mixed or conductive hearing loss groups, the average functional gain (at 500 Hz, 1, 2, 4 kHz) was 26.1 dB HL (SD 13.7), and mean percentage of speech recognition in quiet at 65 dB was 95 % (vs 74 % unaided). In 5/6 SSD subjects, values of SRT in noise were lower with BB. Questionnaires revealed patient benefit and satisfaction. The transcutaneous BCI is very well tolerated at 1-year follow up, improves audiometric thresholds and intelligibility for speech in quiet and noise, and gives satisfaction to both patients with mixed and conductive hearing loss and patients with SSD | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Multicenter Study | |
650 | 4 | |a Bonebridge | |
650 | 4 | |a Conductive and mixed hearing loss | |
650 | 4 | |a Direct-drive | |
650 | 4 | |a Percutaneous | |
650 | 4 | |a Questionnaires | |
650 | 4 | |a Single-sided deafness | |
650 | 4 | |a Transcutaneous bone-conduction implant | |
700 | 1 | |a Deguine, O |e verfasserin |4 aut | |
700 | 1 | |a Marx, M |e verfasserin |4 aut | |
700 | 1 | |a Van de Heyning, P |e verfasserin |4 aut | |
700 | 1 | |a Sterkers, O |e verfasserin |4 aut | |
700 | 1 | |a Mosnier, I |e verfasserin |4 aut | |
700 | 1 | |a Garin, P |e verfasserin |4 aut | |
700 | 1 | |a Godey, B |e verfasserin |4 aut | |
700 | 1 | |a Vincent, C |e verfasserin |4 aut | |
700 | 1 | |a Venail, F |e verfasserin |4 aut | |
700 | 1 | |a Mondain, M |e verfasserin |4 aut | |
700 | 1 | |a Deveze, A |e verfasserin |4 aut | |
700 | 1 | |a Lavieille, J P |e verfasserin |4 aut | |
700 | 1 | |a Karkas, A |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery |d 1994 |g 274(2017), 4 vom: 30. Apr., Seite 1835-1851 |w (DE-627)NLM012637548 |x 1434-4726 |7 nnns |
773 | 1 | 8 | |g volume:274 |g year:2017 |g number:4 |g day:30 |g month:04 |g pages:1835-1851 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00405-016-4228-6 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 274 |j 2017 |e 4 |b 30 |c 04 |h 1835-1851 |