In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples
Copyright © 2016 Elsevier B.V. All rights reserved..
A novel online approach involving in-syringe magnetic stirring assisted dispersive liquid-liquid microextraction and derivatization coupled to gas chromatography-mass spectrometry has been developed for the determination of seven UV filters extensively used in cosmetic products in environmental water samples. The effect of parameters such as the type and volume of extraction solvent, dispersive solvent and derivatization agent, pH, ionic strength and stirring time, was studied using multivariate experimental design. Extraction, derivatization and preconcentration were simultaneously performed using acetone as dispersive solvent, N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) as derivatization agent and trichloroethylene as extraction solvent. After stirring during 160s, the sedimented phase was transferred to a rotary micro-volume injection valve (3 μL) and introduced by an air stream into the injector of the GC through a stainless-steel tube used as interface. The detection limits were in the range of 0.023-0.16 μg L(-1) and good linearity was observed up to 500 μg L(-1) of the studied UV filters, with R(2) ranging between 0.9829 and 0.9963. The inter-day precision expressed as relative standard deviation (n=5) varied between 5.5 and 16.8%. Finally, the developed method was satisfactorily applied to assess the occurrence of the studied UV filters in seawater and pool water samples. Some of the studied UV filters were found in these samples and an add-recovery test was also successfully performed with recoveries between 82 and 111%.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2016 |
---|---|
Erschienen: |
2016 |
Enthalten in: |
Zur Gesamtaufnahme - volume:1443 |
---|---|
Enthalten in: |
Journal of chromatography. A - 1443(2016) vom: 22. Apr., Seite 26-34 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Clavijo, Sabrina [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 21.09.2016 Date Revised 02.12.2018 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.chroma.2016.03.036 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM258799064 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM258799064 | ||
003 | DE-627 | ||
005 | 20231224185810.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2016 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.chroma.2016.03.036 |2 doi | |
028 | 5 | 2 | |a pubmed24n0862.xml |
035 | |a (DE-627)NLM258799064 | ||
035 | |a (NLM)27016119 | ||
035 | |a (PII)S0021-9673(16)30301-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Clavijo, Sabrina |e verfasserin |4 aut | |
245 | 1 | 0 | |a In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples |
264 | 1 | |c 2016 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 21.09.2016 | ||
500 | |a Date Revised 02.12.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2016 Elsevier B.V. All rights reserved. | ||
520 | |a A novel online approach involving in-syringe magnetic stirring assisted dispersive liquid-liquid microextraction and derivatization coupled to gas chromatography-mass spectrometry has been developed for the determination of seven UV filters extensively used in cosmetic products in environmental water samples. The effect of parameters such as the type and volume of extraction solvent, dispersive solvent and derivatization agent, pH, ionic strength and stirring time, was studied using multivariate experimental design. Extraction, derivatization and preconcentration were simultaneously performed using acetone as dispersive solvent, N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) as derivatization agent and trichloroethylene as extraction solvent. After stirring during 160s, the sedimented phase was transferred to a rotary micro-volume injection valve (3 μL) and introduced by an air stream into the injector of the GC through a stainless-steel tube used as interface. The detection limits were in the range of 0.023-0.16 μg L(-1) and good linearity was observed up to 500 μg L(-1) of the studied UV filters, with R(2) ranging between 0.9829 and 0.9963. The inter-day precision expressed as relative standard deviation (n=5) varied between 5.5 and 16.8%. Finally, the developed method was satisfactorily applied to assess the occurrence of the studied UV filters in seawater and pool water samples. Some of the studied UV filters were found in these samples and an add-recovery test was also successfully performed with recoveries between 82 and 111% | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Aqueous silylation | |
650 | 4 | |a Environmental water samples | |
650 | 4 | |a GC–MS | |
650 | 4 | |a In-syringe magnetic-stirring-assisted dispersive liquid–liquid microextraction | |
650 | 4 | |a Online sample treatment | |
650 | 4 | |a UV filters | |
650 | 7 | |a Sunscreening Agents |2 NLM | |
650 | 7 | |a Water Pollutants, Chemical |2 NLM | |
650 | 7 | |a Water |2 NLM | |
650 | 7 | |a 059QF0KO0R |2 NLM | |
700 | 1 | |a Avivar, Jessica |e verfasserin |4 aut | |
700 | 1 | |a Suárez, Ruth |e verfasserin |4 aut | |
700 | 1 | |a Cerdà, Víctor |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of chromatography. A |d 1993 |g 1443(2016) vom: 22. Apr., Seite 26-34 |w (DE-627)NLM074731416 |x 1873-3778 |7 nnns |
773 | 1 | 8 | |g volume:1443 |g year:2016 |g day:22 |g month:04 |g pages:26-34 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.chroma.2016.03.036 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 1443 |j 2016 |b 22 |c 04 |h 26-34 |