Performance Evaluation of CLIA for Treponema Pallidum Specific Antibodies Detection in Comparison with ELISA
© 2015 Wiley Periodicals, Inc..
OBJECTIVES: In this study we aimed to evaluate the performance effects of chemiluminescence assay (CLIA) for Treponema pallidum specific antibodies detection, and to compare T. pallidum specific antibodies detection accuracy between CLIA and ELISA with TPPA (T. pallidum particle agglutination assay) as a confirmatory test.
METHODS: A total of 865 samples from suspected syphilis patients and preoperative patients were included, in which T. pallidum specific antibodies were simultaneously detected by CLIA and ELISA. Among them, 457 samples were determined by TPPA.
RESULTS: All coefficients of variation (CVs) of ELISA in high-, median-, and low-level samples were more than 5% and the maximum CV was 54.39% in the low-level sample. CVs of CLIA in different-level samples were all below 5%. Among the three assays the Spearman correlation and Kappa coefficients were 0.771 (P ≤ 0.001) and 0.854 (P ≤ 0.001, CLIA vs. ELISA), 0.806 (P ≤ 0.001) and 0.897 (P ≤ 0.001, ELISA vs. TPPA), 0.937 (P ≤ 0.001) and 0.967 (P ≤ 0.001, CLIA vs. TPPA), respectively. The area under the receiver operating characteristic curve (AUC) of CLIA was higher than that of ELISA (0.994 vs. 0.989) with TPPA as the confirmatory test. In 18 discrepant samples the consistency rate between CLIA and TPPA was elevated compared with that between ELISA and TPPA (72.22% vs. 27.78%, P = 0.008). In gray zone, the consistency rate of CLIA with TPPA was higher than that of ELISA with TPPA (90.91% vs. 41.67%, P = 0.027).
CONCLUSIONS: Compared with ELISA, CLIA is more reliable, sensitive and accurate to detect serum T. pallidum specific antibodies. In the future it may be an alternative test with higher sensitivity to ELISA.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2016 |
---|---|
Erschienen: |
2016 |
Enthalten in: |
Zur Gesamtaufnahme - volume:30 |
---|---|
Enthalten in: |
Journal of clinical laboratory analysis - 30(2016), 3 vom: 18. Mai, Seite 216-22 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Li, Lixin [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 13.02.2017 Date Revised 10.04.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/jcla.21839 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM246568186 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM246568186 | ||
003 | DE-627 | ||
005 | 20231224143337.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2016 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/jcla.21839 |2 doi | |
028 | 5 | 2 | |a pubmed24n0821.xml |
035 | |a (DE-627)NLM246568186 | ||
035 | |a (NLM)25716172 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Li, Lixin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Performance Evaluation of CLIA for Treponema Pallidum Specific Antibodies Detection in Comparison with ELISA |
264 | 1 | |c 2016 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 13.02.2017 | ||
500 | |a Date Revised 10.04.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2015 Wiley Periodicals, Inc. | ||
520 | |a OBJECTIVES: In this study we aimed to evaluate the performance effects of chemiluminescence assay (CLIA) for Treponema pallidum specific antibodies detection, and to compare T. pallidum specific antibodies detection accuracy between CLIA and ELISA with TPPA (T. pallidum particle agglutination assay) as a confirmatory test | ||
520 | |a METHODS: A total of 865 samples from suspected syphilis patients and preoperative patients were included, in which T. pallidum specific antibodies were simultaneously detected by CLIA and ELISA. Among them, 457 samples were determined by TPPA | ||
520 | |a RESULTS: All coefficients of variation (CVs) of ELISA in high-, median-, and low-level samples were more than 5% and the maximum CV was 54.39% in the low-level sample. CVs of CLIA in different-level samples were all below 5%. Among the three assays the Spearman correlation and Kappa coefficients were 0.771 (P ≤ 0.001) and 0.854 (P ≤ 0.001, CLIA vs. ELISA), 0.806 (P ≤ 0.001) and 0.897 (P ≤ 0.001, ELISA vs. TPPA), 0.937 (P ≤ 0.001) and 0.967 (P ≤ 0.001, CLIA vs. TPPA), respectively. The area under the receiver operating characteristic curve (AUC) of CLIA was higher than that of ELISA (0.994 vs. 0.989) with TPPA as the confirmatory test. In 18 discrepant samples the consistency rate between CLIA and TPPA was elevated compared with that between ELISA and TPPA (72.22% vs. 27.78%, P = 0.008). In gray zone, the consistency rate of CLIA with TPPA was higher than that of ELISA with TPPA (90.91% vs. 41.67%, P = 0.027) | ||
520 | |a CONCLUSIONS: Compared with ELISA, CLIA is more reliable, sensitive and accurate to detect serum T. pallidum specific antibodies. In the future it may be an alternative test with higher sensitivity to ELISA | ||
650 | 4 | |a Evaluation Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Treponema pallidum particle agglutination assay (TPPA) | |
650 | 4 | |a Treponema pallidum specific antibodies | |
650 | 4 | |a chemiluminescence assay (CLIA) | |
650 | 4 | |a enzyme immunoassay (EIA) | |
650 | 4 | |a syphilis | |
650 | 7 | |a Antibodies, Bacterial |2 NLM | |
700 | 1 | |a Cai, Bei |e verfasserin |4 aut | |
700 | 1 | |a Tao, Chuanmin |e verfasserin |4 aut | |
700 | 1 | |a Wang, Lanlan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical laboratory analysis |d 1991 |g 30(2016), 3 vom: 18. Mai, Seite 216-22 |w (DE-627)NLM012927694 |x 1098-2825 |7 nnns |
773 | 1 | 8 | |g volume:30 |g year:2016 |g number:3 |g day:18 |g month:05 |g pages:216-22 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/jcla.21839 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 30 |j 2016 |e 3 |b 18 |c 05 |h 216-22 |