Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery

BACKGROUND: Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification.

MATERIALS AND METHODS: Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed.

RESULTS: A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners.

CONCLUSIONS: The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.

Medienart:

E-Artikel

Erscheinungsjahr:

2015

Erschienen:

2015

Enthalten in:

Zur Gesamtaufnahme - volume:10

Enthalten in:

PloS one - 10(2015), 2 vom: 15., Seite e0117604

Sprache:

Englisch

Beteiligte Personen:

Lin, Hsiu-Hsia [VerfasserIn]
Chuang, Ya-Fang [VerfasserIn]
Weng, Jing-Ling [VerfasserIn]
Lo, Lun-Jou [VerfasserIn]

Links:

Volltext

Themen:

Comparative Study
Journal Article
Research Support, Non-U.S. Gov't

Anmerkungen:

Date Completed 04.01.2016

Date Revised 23.02.2019

published: Electronic-eCollection

Citation Status MEDLINE

doi:

10.1371/journal.pone.0117604

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM246109033