Real-time fluorescence Loop-Mediated Isothermal Amplification (LAMP) for rapid and reliable diagnosis of pulmonary tuberculosis
Copyright © 2014 Elsevier B.V. All rights reserved..
A reliable, simple and rapid diagnostic method that can be helpful in pulmonary tuberculosis diagnosis is urgently needed. Loop-mediated Isothermal Amplification (LAMP) allows DNA to be amplified rapidly at a constant temperature. In this study, real-time fluorescence LAMP was evaluated to rapidly detect Mycobacterium tuberculosis in sputum and was compared to the performance of real-time fluorescence quantitative PCR (Q-PCR). All the standard MTB strains were successfully detected and limit of detection (LOD) was 10(2)CFU/mL by real-time fluorescence LAMP within 20min. In light of MTB in sputum, the real-time fluorescence LAMP method yielded a sensitivity of 98.0% and a specificity of 78.3%, compared to Q-PCR assay, which yielded a sensitivity of 96.0% and a specificity of 82.6% for PTB diagnosis. There was an excellent overall agreement between LAMP and Q-PCR for PTB (κ=0.315) and non-PTB (κ=0.862). Therefore, the real-time fluorescence LAMP assay is a rapid, sensitive, and specific method to detect pulmonary tuberculosis.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2015 |
---|---|
Erschienen: |
2015 |
Enthalten in: |
Zur Gesamtaufnahme - volume:109 |
---|---|
Enthalten in: |
Journal of microbiological methods - 109(2015) vom: 12. Feb., Seite 74-8 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Cao, Donglin [VerfasserIn] |
---|
Links: |
---|
Themen: |
Comparative Study |
---|
Anmerkungen: |
Date Completed 11.09.2015 Date Revised 10.12.2019 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.mimet.2014.12.013 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM244814465 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM244814465 | ||
003 | DE-627 | ||
005 | 20231224135518.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2015 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.mimet.2014.12.013 |2 doi | |
028 | 5 | 2 | |a pubmed24n0816.xml |
035 | |a (DE-627)NLM244814465 | ||
035 | |a (NLM)25533219 | ||
035 | |a (PII)S0167-7012(14)00362-5 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Cao, Donglin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Real-time fluorescence Loop-Mediated Isothermal Amplification (LAMP) for rapid and reliable diagnosis of pulmonary tuberculosis |
264 | 1 | |c 2015 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 11.09.2015 | ||
500 | |a Date Revised 10.12.2019 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2014 Elsevier B.V. All rights reserved. | ||
520 | |a A reliable, simple and rapid diagnostic method that can be helpful in pulmonary tuberculosis diagnosis is urgently needed. Loop-mediated Isothermal Amplification (LAMP) allows DNA to be amplified rapidly at a constant temperature. In this study, real-time fluorescence LAMP was evaluated to rapidly detect Mycobacterium tuberculosis in sputum and was compared to the performance of real-time fluorescence quantitative PCR (Q-PCR). All the standard MTB strains were successfully detected and limit of detection (LOD) was 10(2)CFU/mL by real-time fluorescence LAMP within 20min. In light of MTB in sputum, the real-time fluorescence LAMP method yielded a sensitivity of 98.0% and a specificity of 78.3%, compared to Q-PCR assay, which yielded a sensitivity of 96.0% and a specificity of 82.6% for PTB diagnosis. There was an excellent overall agreement between LAMP and Q-PCR for PTB (κ=0.315) and non-PTB (κ=0.862). Therefore, the real-time fluorescence LAMP assay is a rapid, sensitive, and specific method to detect pulmonary tuberculosis | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Evaluation Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Loop-Mediated Isothermal Amplification (LAMP) | |
650 | 4 | |a Pulmonary tuberculosis | |
650 | 4 | |a Rapid diagnosis | |
700 | 1 | |a Hu, Liangshan |e verfasserin |4 aut | |
700 | 1 | |a Lin, Maorui |e verfasserin |4 aut | |
700 | 1 | |a Li, Mingyou |e verfasserin |4 aut | |
700 | 1 | |a Ye, Zebing |e verfasserin |4 aut | |
700 | 1 | |a Sun, Hongtao |e verfasserin |4 aut | |
700 | 1 | |a Huang, Jiwei |e verfasserin |4 aut | |
700 | 1 | |a Yang, Huawen |e verfasserin |4 aut | |
700 | 1 | |a Tian, Junzhang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of microbiological methods |d 1983 |g 109(2015) vom: 12. Feb., Seite 74-8 |w (DE-627)NLM082816786 |x 1872-8359 |7 nnns |
773 | 1 | 8 | |g volume:109 |g year:2015 |g day:12 |g month:02 |g pages:74-8 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.mimet.2014.12.013 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 109 |j 2015 |b 12 |c 02 |h 74-8 |